##0791 [TX/RX] During an ECM mode procedure, a signal other than a signifi-
cant signal was received
Cause:
The procedure signal is faulty.
Remedy:
Record the protocol on a DAT or MD, and have it analyzed by the local Canon of-
fice and/or Technical Center.
##0792 [RX]
In ECM reception, PPS-NULL between partial pages cannot be de-
tected
Cause:
The line condition is poor, and PPS-NULL cannot be received.
Remedy:
(1) Ask the operator of the other party to increase the transmission level so that
(2) Adjust the NL equalizer so that PPS-NULL may be received correctly.
##0793 [RX]
In ECM reception, no effective frame was detected while signals
were received at high speed, and a time-over condition occurred
Cause:
The line condition is poor, and the other party cannot receive CFR correctly.
Remedy:
(1) Increase the transmission level so that the other party may receive CFR cor-
(2) Adjust the NL equalizer so that the other party may receive CFR correctly.
Cause:
The line condition is poor, and the image signal cannot be received correctly.
Remedy:
(1) Ask the operator of the other party to increase the transmission level so that the
(2) Ask the operator of the other party to decrease the transmission start speed.
Cause:
An echo of CFR prevents reception of the training signal.
Remedy:
(1) Provide echo remedy 3.
(2) Decrease the transmission level so that an echo of the transmitted CFR will not
##0795 [TX/RX] A fault occurred in decoding process during a communication
Cause:
The communication CODEC is busy.
Remedy:
(1) Turn off and then on the power.
(2) Replace the image processor PCB.
COPYRIGHT© 2002 CANON INC.
PPS-NULL may be received correctly.
rectly.
image signal may be received correctly.
be received.
2000
CANON iR1600/iR2000/iR1610/iR2010 SERIES REV.0 MAR. 2002
CHAPTER 13 TROUBLESHOOTING
13-225