14) If the measurement is not as indicated,
perform the following:
• If the resistance between the earth con-
tact and the fixing roller core [22] is
not as indicated, check to make sure
that the static eliminating brush [24] is
in contact with the fixing roller core
[22].
• If the resistance between the earth con-
tact and the inlet guide [23] is not as
indicated, check to make sure that the
contact plate [24] is in contact with the
inlet guide [23].
15) After the checks, put back the fixing
assembly by reversing the steps.