Page 1
Operating and Installation Instructions Range Wall / Insert Hood To prevent accidents and damage to the appliance, you must read these instructions before installing the appliance and using it for the first time. en-US M.-Nr. 10 463 980...
Contents Caring for the environment .................. 3 IMPORTANT SAFETY INSTRUCTIONS .............. 4 Guide to the appliance .................. 12 Description of functions .................. 14 Appliance combinations..................15 Operation...................... 16 Switch on the blower..................... 16 Turning off the blower.................... 17 Turning the overhead lighting on/off..............17 Energy-saving tips....................
Consult with local authorities, dealers or Miele in order to dispose of and recycle electrical and electronic appliances. Miele assumes no responsibility for deleting any personal data left on the appliance being disposed.
IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS This appliance complies with current safety requirements. Improper use of the appliance can lead to personal injury and material damage. Read all instructions before installing or using the appliance for the first time. Only use the appliance for its intended purpose. Keep these operating instructions in a safe place and pass them on to any future user.
Page 5
Unauthorized installation, maintenance, and repairs can cause considerable danger for the user. Installation, maintenance, and repairs must only be carried out by a Miele authorized technician. A damaged ventilation hood can be dangerous. Always check for visible signs of damage. Never use a damaged ventilation hood.
Page 6
Tampering with electrical connections or components and mechanical parts is highly dangerous to the user and can cause operation faults. Defective components should be replaced by Miele original parts only. Only with these parts can the manufacturer guarantee the safety of the appliance. ...
Page 7
IMPORTANT SAFETY INSTRUCTIONS – The screw-type fuses on the electrical service panel have been removed. – The power cord (if present) has been unplugged from the socket (pull the plug not the cord). Correct use WARNING: TO REDUCE THE RISK OF A COOKTOP GREASE FIRE: –...
Page 8
IMPORTANT SAFETY INSTRUCTIONS WARNING: TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A COOKTOP GREASE FIRE, OBSERVE THE FOLLOWING*: – a) SMOTHER FLAMES with a close fitting lid, cookie sheet, or metal tray then turn off the burner. BE CAREFUL TO PREVENT BURNS.
Page 9
IMPORTANT SAFETY INSTRUCTIONS Overheated oil and fat can ignite, causing fire damage to the ventilation system. Do not leave cookware, pans, and deep fryers unattended when cooking with oil or fat. Similarly, never leave an open grill unattended when grilling. ...
Page 10
IMPORTANT SAFETY INSTRUCTIONS Proper installation WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: – a) Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.
Page 11
Never use a steam cleaner to clean the ventilation hood. The steam can reach the electrical components and cause a short circuit. Accessories Use only genuine original Miele parts. If parts or accessories from other manufacturers are used, the warranty will become void.
Page 13
Guide to the appliance a Duct cover Optional accessories DRDC in various heights. Cover will vary depending on model. b Recirculation vents Only in recirculation mode with conversion kit DRUU, optional accessory c Canopy d OdorFree Charcoal Filter Optional accessories for recirculation mode. The charcoal filters are mounted to the rear panel of the baffle filter.
Description of functions The following functions are available on Recirculating mode your ventilation hood, depending on the (with conversion kit DRUU) model: Vented mode with internal blower DRIB The baffle filter and the additional additional charcoal filter clean the indrawn air. Then the air is recirculated to the kitchen.
Description of functions Appliance combinations The following appliance combinations are possible: Vented mode with Vented mode with Recirculating Duct cover internal blower external blower mode Range Insert Blower Blower DAR 1120 (30") DRIB XL or DREB XL or DRIB XXL* DREB XXL* Range Insert Blower...
Operation Switch on the blower Ventilation hood with blower DRIB/ DREB XL (700 cfm) Power levels 1 to 3 are available for light to heavy cooking vapors and odors. Gas power level Minimum switched on blower level If heavy cooking vapors and odors occur temporarily, e.g., during frying, from approx.
Operation Turning off the blower It is advisable to run the blower for a few minutes after cooking has finished to neutralize any lingering vapors and odors in the air. To turn the blower off, turn the blower switch to 0. Turning the overhead lighting on/off The overhead lighting can be turned on...
Energy-saving tips This hood operates in a very efficient and energy-saving manner. The following will help you to save even more energy when using it: – Ensure that there is sufficient ventilation in the kitchen when cooking. If there is insufficient air flow during vented mode, the hood cannot operate efficiently, causing increased operating noise levels.
Cleaning and care Special instructions for stainless WARNING: TO REDUCE THE steel surfaces RISK OF FIRE, ELECTRIC SHOCK, Stainless steel surfaces can also be OR INJURY TO PERSONS, cleaned using a non-abrasive OBSERVE THE FOLLOWING: stainless steel cleaner. ...
Cleaning and care Removing the baffle filter Baffle filter The reusable stainless steel baffle When handling the grease filter, grease filters in the appliance absorb be careful not to drop it. the solid particles of kitchen vapors This can result in damage to the filter (grease, dust, etc.) and prevent soiling and the cooktop below.
Page 21
Ensure the spray arm is not obstructed. Use a common dishwashing detergent. Pull the grease tray upward and In a Miele dishwasher user either the remove it. “Normal” or “Grates and Filters” For cleaning purposes, observe the programm.
Page 22
Cleaning and care Reinsert the baffle filters by pushing the filter upwards then pushing it in .
The charcoal filters are installed on the back side of the baffle filters. You can purchase the OdorFree Charcoal Filter from Miele. The type and designation can be found in chapter “Technical Data”. How to install/replace the charcoal filter ...
Miele This service is available in USA only. dealer or Miele Technical Service. The telephone number for Miele is listed MieleCare, our Extended Service at the back of these instructions. Contract program, gives you the...
Installation Before installation Installation Instructions Please refer to the accompanying Before installing the appliance, installation sheet for instructions on read all of the information contained how to install the appliance. in this chapter and also in the “IMPORTANT SAFETY INSTRUCTIONS”...
Page 27
Installation a 1 vent collar for exhaust duct 9 3/4" (250 mm). The vent collar is not used for 2 self-locking screws, M6 x 16 mm recirculation mode. for attaching the DAR 12xx to the mounting rail. b 1 mounting rail for mounting the DAR 12xx on a wall c 2 mounting brackets 4 screws, M4 x 11 mm with base and for mounting the DAR 12xx on a wall...
Installation DRDC duct covers, a Minimum height required for exhaust DRUU recirculation conversion kits air penetration when using a vent duct. b Recommended installation area for the electrical connection. c Attachment points: there must be a sub-construction capable of bearing the load in the area of the attachment point.
Page 32
(700 cfm) (700 cfm) (1100 cfm) (1100 cfm) Miele electric/induction cooktops 24" (610 mm) Miele barbeque and fryer (electric) 26" (660 mm) Multi-burner Miele gas cooktop, 26" (660 mm) ≤ 43,000 BTU/h (12.6 kW), none of the burners > 19,800 BTU/h (5.8 kW) Multi-burner Miele gas cooktop, 30"...
Installation recommendations (M Pro Power, M Pro) – A distance of at least 26" (660 mm) is recommended above electric If the BTU-reducing kit for Miele cooktops to provide more workspace Ranges/Rangetops is in use, the and easier cooking under the hood.
Installation Find the studs to the left and right Plywood backing of the mounting location by tapping The majority of the weight of the the wall or using a stud finder. installed ventilation system will be Mark a vertical cutting line along the supported by the lower retaining center of each stud.
Air venting WARNING: Danger of toxic fumes. Only use smooth pipes or flexible Gas cooking appliances release duct hoses made from non- carbon monoxide that can be combustible materials for exhaust harmful or fatal if inhaled. duct. To reduce the risk of fire and to To achieve the greatest possible air properly exhaust air, the exhaust extraction with the lowest noise levels,...
Page 36
Air venting When duct is horizontal it must be laid to slope away at at least ¹/₈ inch per foot. This is to ensure that condensate cannot drain back into the appliance. If the exhaust duct is to be routed through rooms, ceiling space etc., the temperatures in these different areas may differ greatly, which means that...
CSA C22.1-12, please consult a licensed electrician Canadian Electrical Code, Part I. or call Miele’s Technical Service Department. WARNING: THIS APPLIANCE MUST BE GROUNDED...
Technical data Total connected load DAR 1120, 1220 with blower DRIB XL or DREB XL 621 W DAR 1130, 1230 with blower DRIB XL or DREB XL 624 W DAR 1130, 1230 with blower DRIB XXL or DREB XXL 809 W DAR 1150, 1250, 1260 with blower DRIB XXL or DREB XXL 812 W Overhead lighting...
Page 39
Technical Service. U.S.A. Canada Miele, Inc. Importer Miele Limited National Headquarters 9 Independence Way Headquarters and Miele Centre Princeton, NJ 08540 161 Four Valley Drive Phone: 800-843-7231 Vaughan, ON L4K 4V8 609-419-4298 Fax: www.miele.ca www.mieleusa.com...
Page 40
DAR 1120, DAR 1130, DAR 1150 DAR 1220, DAR 1230, DAR 1250, DAR 1260 en-US M.-Nr. 10 463 980 / 04...