2014/30/EU (EMC - Electromagnetic Compatibility directive) 2014/53/EU (RED - Radio Equipment directive) 2011/65/EU (ROhS) Hereby CADEL S.r.l. declares that the radio equipment type Easy Connect Plus + Navel Stand Alone is in compliance with Directive 2014/53/EU. SHELL UP - SHELL PS -BREEZE AIRTIGHT...
No part of this manual may be translated into other languages, adapted and/or reproduced, even in part, in other mechanical and/ or electronic form or media, for photocopies, recordings or other, without the prior written authorisation of CADEL S.r.l. The company reserves the right to make changes to the product at any time without prior notice. The owner company reserves its rights according to law.
SAFETY REQUIREMENTS • Installation, electrical connection, functional verification and maintenance must only be performed by qualified or authorised personnel. • Live electrical parts: disconnect the product from the 230V power supply before perfor- ming any maintenance operation. Only power the product after completing assembly. •...
experience and knowledge must be kept away from packaging. The stove IS NOT a toy. • Childreen must be constantly overseen in order to assure that they do not play with the appliance. • During its running, the stove reaches high temperatures: keep away childreen and animals and for your safety please use appropriate fireproof devices, such as heat-protecting gloves.
WARRANTY CONDITIONS The duration, conditions and limitations of CADEL S.r.l. can be found on the guarantee card enclosed with the device. The company guarantees the product, with the exception of elements subject to normal wear listed below, for a period of 2 (two) years from the date of purchase attested by: •...
tions and in accordance with the fee in force for the work to be carried out. The user will also be charged for any costs incurred to remedy the incorrect technical interventions, tampering or damage to the appliance, not attributable to original faults. Save for the legal or regulatory limits, the guarantee does not cover the containment of atmospheric and acoustic pollution.
LEGENDA WHERE TO DISPOSE MATERIALS Metal Glass If there is any, to be disposed of separately based on A. OUTER CLADDING the material used: Tiles or ceramics Stone Glass ceramic (fire door): to be disposed of with inert or mixed waste If there is any, to be disposed of separately based on B.
INSTRUCTIONS FOR PACKAGING DISPOSAL The material that the appliance’s packaging is made of must be managed correctly, in order to make collection, reuse, recovery and recycling easier, where possible. The table below illustrates the possible components that the packaging is made of, and the relative instructions for correct disposal. DESCRIPTION CODE MATERIAL SYMBOL...
Fig. 3 - EASY CONNECT PLUS module Fig. 4 - EASY CONNECT PLUS display Fig. 5 - EASY CONNECT PLUS app The documentation for connecting the Wi-Fi and using the App are available online at the following addresses: https://www.cadelsrl.com/donwload-wi-fi/ http://www.free-point.it/it/downloads/ https://www.pegasoheating.com/it/documenti/ NAVEL STAND ALONE (OPTIONAL) Procedure if only valid for models with NAVEL STAND ALONE Wi-Fi technology.
Fig. 6 - NAVEL STAND ALONE module Fig. 7 - App EASY CONNECT PLUS The documentation for connecting the Wi-Fi and using the App are available online at the following addresses: https://www.cadelsrl.com/donwload-wi-fi/ http://www.free-point.it/it/downloads/ https://www.pegasoheating.com/it/documenti/ INTRODUCTION To have the best performance with the lowest consumption please follow the here descripted instructions. •...
Fig. 8 - Control panel Fig. 9 - Control panel (wi-fi) Fig. 10 - Display LEGEND Fig. 8|Fig. 9|Fig. 10 Boiler lighting/shutdown (ESC) Scrolling of programming menu to decrease Menu Scrolling of programming menu to increase Decrease set temperature/programming functions Increase set temperature/programming functions Display Time...
Page 14
i - Smoke Fan rpm j - Components Test (displayed only when the boiler is switched off) k - Chimney Sweep Function (activated only when the boiler is switched on, for field emissions test) l - Technical Menu a - Language To select the language act as follows: •...
Page 15
To select the Off Time Eco function act as follows: • Press the “menu” button. • Scroll to “Settings” using the arrows • Press “menu” to confirm. • Scroll to “Off Time Eco” using the arrows. • Press “menu” to confirm. •...
l - Technical Menu To access the technical menu one must contact an assistance centre as one needs a password to enter. INFO MENU • Product Type • Firmware Version • Software info • Total hrs. • Ignition N. • Rpm Smoke Fan •...
SWITCH OFF (ON PANEL: OFF WITH FLASHING FLAME) If the shutdown key is pressed or if there is an alarm signal, the boiler goes into the thermal shutdown phase which entails the automatic execution of the following stages: • Pellet loading is stopped. •...
If the stove is set to maximum heat output 5 and the fans to minimum output 1, this may cause overheating and the “THERMAL SAFETY” alarm to go off. Comfort Mode - In the air versions, it cannot be deactivated. At power 1 the fans are off. In versions with ducting, the comfort mode allows you to automatically activate or deactivate all the fans at power 1.
8.12 PROGRAMMING EXAMPLES: 08:00 12:00 11:00 14:00 Boiler on from 08:00 to 14:00 08:00 11:00 11:00 14:00 Boiler on from 08:00 to 14:00 17:00 24:00 00:00 06:00 Boiler on from 17:00 on monday to 06:00 on tuesday 8.13 NOTES FOR TIMER OPERATION •...
• Scroll to SLEEP with the <> arrows • Press Menu • With the + - keys adjust the desired shutdown time. The panel proposes a shutdown time of 10 minutes from the current time, adjustable with key 4 until the next day (I can therefore delay the shutdown for up to a maximum of 23 hours and 50 minutes).
8.17 PELLETS RECIPE (SEE SECTION H SETTINGS MENU A PAG. 13) Changes to be made with the support of the authorised technician. Activates only with the Easy Set function disabled, "SET: 0" ! This function is for adapting the stove to the pellets that are being used. In fact, as there are several types of pellets on the market, boiler operation is extremely variable depending on the fuel quality.
Humid pellets cause a bad combustion and running, so please assure you that they are stored in dry places and far at least one meter from the stove and/or any other source of heat. • It is advisable to try different type of pellets available on the market and to choose that which gives the best performance. •...
Fig. 26 - Door open Fig. 27 - deteriorated gasket Fig. 28 - Timer: 90 seconds To operate correctly, the stove must work with the pellet hopper door always closed; should it remain open for more than 90 seconds, the stove switches off. •...
Fig. 30 - Remote control LEGEND Fig. 30 Button 1 Increase the desired temperature (5÷35 °C) Button 2 Decrease the desired temperature (35÷5 °C) Button 3 On / off Button 4 Menu Button 5 Decrease the power level from 5 to 1 Button 6 Increase the power level from 1 to 5 SAFETY DEVICES AND ALARMS...
12.8 FAILED START-UP If during ignition no flame develops, the boiler will go into alarm condition. 12.9 BLACKOUT WITH THE BOILER ON In the event of a power cut (BLACKOUT) the boiler behaves as follows: • Blackout below 10”: it returns to its operation in progress; •...
ROUTINE MAINTENANCE 13.1 INTRODUCTION For a long working life of the stove, have a periodic cleaning of the stove as described in the following paragrafs. • Fume outlet pipes (fume conduit + chimney flue + chimney pot) must always be cleaned, scrubbed and checked by an autho- rized technician in compliance with local regulations, with the instructions of the manufacturer and those of your insurance company.
Fig. 33 - Cleaning LEGEND Fig. 33 Ash drawer Burning pot Burning pot compartment 13.4 HOPPER CLEANING Fig. 34 - Hopper cleaning Per each pellets supply, check the probable presence of meal, sawdust and other remanins on the hopper bottom. If present, they must be removed with the aid of a vacuum cleaner (see Fig.
13.9 GASKET REPLACEMENT In case of deterioration of fire door, hopper or fume chamber gaskets, it is necessary to replace them by an autorized technician in order to guarantee the good running of the stove. Use exclusively original spare parts. 13.10 GLASS CLEANING The glass-ceramic of the fire door is able to stand till 700°C but not to thermal shocks.
USER/TECHNICIAN PARTS/FREQUENCY 1 DAY 2-3 DAYS 7 DAYS 1 YEAR Brazier UNDER THE USER'S RESPONSIBILITY Ash compartment ** Glass Upper exchanger Lower exchanger BY THE QUALIFIED TECHNICIAN Smoke duct Gaskets Door closure operation ** Emptying of the ash compartment depends on various factors (pellet type, stove power, stove use, type of installation...); the exact emptying time will be suggested by experience.
Page 30
PROBLEM CAUSE SOLUTION INTERVENTION Empty hopper Full the hopper. Open fire door or Close fire door and pellet door and check that there are no pellet open pellet door grains at the gasket level. Clogged stove Fume chamber cleaning Pellets do not reach the combustion Auger blocked by a chamber...
Page 31
PROBLEM CAUSE SOLUTION INTERVENTION Faulty fume tempe- Replace the fume probe. The exchanger fan rature probe continues to turn even though the stove has just cooled Faulty mother board Replace the mother board. Faulty or out of order Replace the gaskets. door gaskets Ash remains along Contact an expert stove-repairer who will immediately provide for...
TECHNICAL DOCUMENTATION FOR LOCAL SPACE HEATERS ACCORDING TO COM- MISSION REGULATIONS (EU) 2015/1185 - (EU) 2015/1186 (PRODUCT FICHE) CADEL srl - Via Foresto Sud 7 - 31025 Santa Lucia di Piave (TV) - Italy Manufacturer CADEL: KRISS3 - 9kW - SHELL3 UP - SHELL3 PS...
Page 33
Rev. 00 - 2022 CADEL srl www.cadelsrl.com 31025 S. Lucia di Piave - TV www.free-point.it Via Foresto sud, 7 - Italy www.pegasoheating.com Tel. +39.0438.738669 Fax +39.0438.73343...