hit counter script
Siemens RUGGEDCOM RX1501 Installation Manual

Siemens RUGGEDCOM RX1501 Installation Manual

Simatic net
Hide thumbs Also See for RUGGEDCOM RX1501:

Advertisement

Quick Links

All manuals and user guides at all-guides.com
Installation Manual
SIMATIC NET
Rugged Multi Service Platforms
RUGGEDCOM RX1501
Edition
05/2020
https://www.siemens.com

Advertisement

Table of Contents
loading

Summary of Contents for Siemens RUGGEDCOM RX1501

  • Page 1 All manuals and user guides at all-guides.com Installation Manual SIMATIC NET Rugged Multi Service Platforms RUGGEDCOM RX1501 Edition 05/2020 https://www.siemens.com...
  • Page 2 All manuals and user guides at all-guides.com Preface Introduction Installing the Device SIMATIC NET Device Management Rugged Multi Service Platforms RUGGEDCOM RX1501 Modules Technical Specifications Installation Manual Certification 05/2020 C79000-G8976-1054-17...
  • Page 3 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommend- ed or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 4: Table Of Contents

    Accessing Documentation ....................... v Registered Trademarks ......................v Warranty ..........................vi Training ..........................vi Customer Support ........................vi Contacting Siemens ....................... vii Introduction ........................... 1 Feature Highlights ....................1 Description ......................1 Required Tools and Materials ................. 3 Decommissioning and Disposal ................3 Cabling Recommendations ..................
  • Page 5 European Union (EU) ..................52 6.1.4 FCC ........................53 6.1.5 FDA/CDRH ......................53 6.1.6 ISED ........................53 6.1.7 ACMA ........................54 6.1.8 RoHS ........................54 6.1.9 Other Approvals ....................54 EMC and Environmental Type Tests ..............55 RUGGEDCOM RX1501 Installation Manual, 05/2020, C79000-G8976-1054-17...
  • Page 6: Preface

    All manuals and user guides at all-guides.com Preface This guide describes the RUGGEDCOM RX1501. It describes the major features of the device, installation, commissioning and important technical specifications. It is intended for use by network technical support personnel who are responsible for the installation, commissioning and maintenance of the device.
  • Page 7: Warranty

    Warranty Warranty Siemens warrants this product for a period of five (5) years from the date of pur- chase, conditional upon the return to factory for maintenance during the warranty term. This product contains no user-serviceable parts. Attempted service by unautho- rized personnel shall render all warranties null and void.
  • Page 8: Contacting Siemens

    Call a local hotline center to submit a Support Request (SR). To locate a lo- cal hotline center, visit https://w3.siemens.com/aspa_app/­?lang=en. Mobile App Install the Industry Online Support app by Siemens AG on any Android, Apple iOS or Windows mobile device and be able to: •...
  • Page 9 All manuals and user guides at all-guides.com Preface Contacting Siemens viii RUGGEDCOM RX1501 Installation Manual, 05/2020, C79000-G8976-1054-17...
  • Page 10: Introduction

    (EMI) and heavy electrical surges typical of the harsh environ- ments found in many industrial applications. An operating temperature range of -40 to 85 °C (-40 to 185 °F) allows the RUGGEDCOM RX1501 to be placed in almost any location.
  • Page 11 Device (Page 21)". Utility USB Port Use the USB port to upgrade the RUGGEDCOM RX1501 software or install files, such as configuration files and feature key files. For more information, refer to the RUGGEDCOM ROX Configuration Manual for the RUGGEDCOM RX1501.
  • Page 12: Required Tools And Materials

    All manuals and user guides at all-guides.com Introduction 1.3 Required Tools and Materials Required Tools and Materials The following tools and materials are required to install the RUGGEDCOM RX1501: Tools/Materials Purpose AC/DC power cord (16 AWG) For connecting power to the device.
  • Page 13: Protection On Twisted-Pair Data Ports

    Siemens also does not recommend using copper Ethernet ports to interface with de- vices in the field across distances that could produce high levels of ground potential rise (i.e.
  • Page 14: Installing The Device

    This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by Siemens AG could invalidate specifications, test results, and agency approvals, and void the user's authority to operate the equipment.
  • Page 15: General Procedure

    Inspect the package for damage before opening it. Visually inspect each item in the package for any physical damage. Verify all items are included. NOTICE If any item is missing or damaged, contact Siemens for assistance. RUGGEDCOM RX1501 Installation Manual, 05/2020, C79000-G8976-1054-17...
  • Page 16: Mounting The Device

    "Dimension Drawings (Page 46)". 2.3.1 Mounting the Device to a Rack For rack mount installations, the RUGGEDCOM RX1501 can be equipped with rack mount adapters pre-installed at the front or rear of the chassis. Additional adapters are provided for added stability. NOTICE Vibration hazard –...
  • Page 17: Mounting The Device On A Din Rail

    2.3.2 Mounting the Device on a DIN Rail For DIN rail installations, the RUGGEDCOM RX1501 can be equipped with panel/DIN rail adapters pre-installed on each side of the chassis. The adapters allow the device to be slid onto a standard 35 mm (1.4 in) DIN rail.
  • Page 18: 2.3.3 Mounting The Device To A Panel

    2.3.3 Mounting the Device to a Panel For panel installations, the RUGGEDCOM RX1501 can be equipped with panel/DIN rail adapters pre-installed on each side of the chassis. The adapters allow the device to be attached to a panel using screws.
  • Page 19: Connecting The Failsafe Alarm Relay

    NO contact and closes the NC (Normally Closed) contact. Note Control of the failsafe relay output is configurable through RUGGEDCOM RX1501 . One common application for this relay is to signal an alarm if a power failure occurs.
  • Page 20: Connecting Power

    Figure 2.4 Failsafe Alarm Relay Wiring Connecting Power The RUGGEDCOM RX1501 supports a single high AC, high DC or low DC power mod- ule. Power modules can be equipped with either a screw or European-style (Euroblock) terminal block. The screw terminal block is installed using Phillips screws and com- pression plates, allowing either bare wire connections or crimped terminal lugs.
  • Page 21: Connecting High Ac/Dc Power

    NOTICE Electrical hazard – risk of damage to equipment Do not connect AC power cables to a 12, 24 or 48 VDC power supply terminal block. Damage to the power supply may occur. RUGGEDCOM RX1501 Installation Manual, 05/2020, C79000-G8976-1054-17...
  • Page 22 Ground Terminal Negative/Neutral (-/N) Terminal Figure 2.5 AC Terminal Block Wiring – European-style (Euroblock) Terminal Block for HIP Power Supplies Not Connected Removable Screw Terminal Block Non-removable Screw Terminal Block Positive/Live (+/L) Terminal Ground Terminal RUGGEDCOM RX1501 Installation Manual, 05/2020, C79000-G8976-1054-17...
  • Page 23 For screw terminal blocks, install the safety cover. Screw Safety Cover Screw Terminal Block RUGGEDCOM RX1501 Device Figure 2.7 Assembling the Safety Cover Using a braided wire or other appropriate grounding wire, connect the ground terminal to the chassis ground connection.
  • Page 24: 2.5.2 Connecting Low Dc Power

    Do not connect AC power cables to a 12, 24 or 48 VDC power supply terminal block. Damage to the power supply may occur. Note The RUGGEDCOM RX1501 works with both positive VDC power supplies and negative VDC power supplies. RUGGEDCOM RX1501...
  • Page 25 Ground Terminal Figure 2.9 DC Terminal Block Wiring – European-style (Euroblock) Terminal Block for 12P, 24P and 48P Power Supplies Not Connected Removable Screw Terminal Block Non-removable Screw Terminal Block Positive (+) Terminal Negative (-) Terminal RUGGEDCOM RX1501 Installation Manual, 05/2020, C79000-G8976-1054-17...
  • Page 26 Negative (-) Terminal Ground Terminal Figure 2.11 DC Terminal Block Wiring – European-style (Euroblock) Terminal Block for -12P, -24P and -48P Power Supplies Not Connected Removable Screw Terminal Block Non-removable Screw Terminal Block Positive (+) Terminal RUGGEDCOM RX1501 Installation Manual, 05/2020, C79000-G8976-1054-17...
  • Page 27 Connect the negative wire from the power source to the negative (-) terminal on the terminal block. For screw terminal blocks, install the safety cover. Screw Safety Cover Screw Terminal Block RUGGEDCOM RX1501 Device Figure 2.13 Assembling the Safety Cover RUGGEDCOM RX1501 Installation Manual, 05/2020, C79000-G8976-1054-17...
  • Page 28 #10 Ring Lug #10-32 Screw Connection from External Power Source Ground Connection Figure 2.14 Ground Connection Install the safety cover over the terminal block. This is mandatory for 48 VDC and -48 VDC power supplies. RUGGEDCOM RX1501 Installation Manual, 05/2020, C79000-G8976-1054-17...
  • Page 29 All manuals and user guides at all-guides.com Installing the Device 2.5.2 Connecting Low DC Power RUGGEDCOM RX1501 Installation Manual, 05/2020, C79000-G8976-1054-17...
  • Page 30: Device Management

    This section describes how to connect to and manage the device. Connecting to the Device The following describes the various methods for accessing the RUGGEDCOM RX1501 console and Web interfaces on the device. For more detailed instructions, refer to the RUGGEDCOM ROX Configuration Manual for the RUGGEDCOM RX1501.
  • Page 31: Configuring The Device

    Communication Ports Connect any of the available Ethernet ports on the device to a management switch and access the RUGGEDCOM RX1501 console and Web interfaces via the device's IP address. The factory default IP address for the RUGGEDCOM RX1501 is https://- 192.168.0.2.
  • Page 32 The following will void the warranty and potentially result in configuration data cor- ruption/loss: • Using a CF card not approved by Siemens for use with this device • Removing the CF card in any scenario other than those described in this section...
  • Page 33 CompactFlash Card Access Panel Figure 3.4 Removing the CF Card Press the ejector button to the left of the CF card and then pull the card out. Secure the CF card access panel to the chassis. RUGGEDCOM RX1501 Installation Manual, 05/2020, C79000-G8976-1054-17...
  • Page 34: Modules

    All manuals and user guides at all-guides.com Modules The RUGGEDCOM RX1501 features slots for up to four field-replaceable line modules, which can be used to expand and customize the capabilities of the device to suit spe- cific applications. A variety of modules are available, each featuring a specific type of communica- tion port: copper Ethernet, fiber optic Ethernet, SFP, WAN, cellular modem and DDS.
  • Page 35: Available Modules

    The following is a list of all power and line modules available for use in the RUGGED- COM RX1501. For more information about individual modules, refer to the RUGGED- COM RX1500 Series Modules Catalog [https://support.industry.siemens.com/cs/ca/- en/view/109747072]. RUGGEDCOM RX1501 Installation Manual, 05/2020, C79000-G8976-1054-17...
  • Page 36 Input Range: 13 to 36 6GK6015-0AL11-0AA0 (Standard) Terminal Type: Remov- 6GK6015-0AL11-0AA1 able Screw (Conformal Coated) RUGGEDCOM RX1500PN PS 24P Specifications Article Numbers Input Range: 13 to 36 6GK6015-0AL14-0AA0 (Standard) Terminal Type: Euro- 6GK6015-0AL14-0AA1 pean-style (Euroblock) (Conformal Coated) RUGGEDCOM RX1501 Installation Manual, 05/2020, C79000-G8976-1054-17...
  • Page 37 RUGGEDCOM RX1500PN PS HI (shipped from Specifications Article Numbers 2019 on) Input Range: 88 to 300 6GK6015-0AL13-0AA0 VDC or 85 to 264 VAC (Standard) Terminal Type: Remov- 6GK6015-0AL13-0AA1 able Screw (Conformal Coated) RUGGEDCOM RX1500PN PS HIP Specifications Article Numbers RUGGEDCOM RX1501 Installation Manual, 05/2020, C79000-G8976-1054-17...
  • Page 38 Power Consumption: 4 RUGGEDCOM RX1500PN LM X CG04 Specifications Article Numbers Ports: 2 6GK6015-0AL20-0PH0 (Standard) Speed: 1000 Mbps 6GK6015-0AL20-0PH1 Interface: TX (Conformal Coated) Port Type: M12 (8-pin, X-Coded) Distance: 100 m (328 ft) Power Consumption: 4 RUGGEDCOM RX1501 Installation Manual, 05/2020, C79000-G8976-1054-17...
  • Page 39 Power Consumption: 5 RUGGEDCOM RX1500PN LM 4TX04B Specifications Article Numbers Ports: 4 6GK6015-0AL20-0PG0 (Standard) Speed: 100 Mbps 6GK6015-0AL20-0PG1 Interface: TX (Conformal Coated) Port Type: M12 (4-Pin, A-Coded, Controlled By- pass) Distance: 100 m (328 ft) RUGGEDCOM RX1501 Installation Manual, 05/2020, C79000-G8976-1054-17...
  • Page 40 Mode: SM 6GK6015-0AL20-0EC0 (Standard) Speed: 1000 Mbps 6GK6015-0AL20-0EC1 Interface: LX (Conformal Coated) Wavelength: 820 nm Ports: 4 Port Type: LC Distance: 10 km (6.2 Power Consumption: 5 RUGGEDCOM RX1500PN LM FG50 Specifications Article Numbers RUGGEDCOM RX1501 Installation Manual, 05/2020, C79000-G8976-1054-17...
  • Page 41 (Conformal Coated) RUGGEDCOM RX1500PN LM 6FX51 Specifications Article Numbers Mode: MM 6GK6015-0AL20-0BK0 (Standard) Speed: 100 Mbps 6GK6015-0AL20-0BK1 Interface: FX (Conformal Coated) Wavelength: 1310 nm Ports: 6 Port Type: LC Distance: 2 km (1.2 mi) RUGGEDCOM RX1501 Installation Manual, 05/2020, C79000-G8976-1054-17...
  • Page 42 (Conformal Coated) Power Consumption: 3 RUGGEDCOM RX1500PN LM D02 Specifications Article Numbers Speed: 56 kbps (Mas- 6GK6015-0AL20-0LB0 ter/Slave) or 64 kbps (Standard) (Slave) 6GK6015-0AL20-0LB1 Ports: 1 (Conformal Coated) Port Type: RJ48S Power Consumption: 3 RUGGEDCOM RX1501 Installation Manual, 05/2020, C79000-G8976-1054-17...
  • Page 43 A, 1 x Receive Diversity (Secondary) SIM: Dual Mini-SIM (2FF) Power Consumption: 7 RUGGEDCOM RX1500PN LM W22 Specifications Article Numbers Services: EVDO Rev A 6GK6015-0AL20-0WE0 (Standard) Region: North America (Verizon) 6GK6015-0AL20-0WE1 (Conformal Coated) Port Type: 50 Ω SMA RUGGEDCOM RX1501 Installation Manual, 05/2020, C79000-G8976-1054-17...
  • Page 44 (Conformal Coated) DO/GNSS Region: North Ameri- ca (AT&T, Rogers, Bell, Telus) Port Type: 50 Ω SMA Antennas: 1 x LTE Main, 1 x LTE MIMO, 1 x GPS SIM: Dual Mini-SIM (2FF) Power Consumption: 7 RUGGEDCOM RX1501 Installation Manual, 05/2020, C79000-G8976-1054-17...
  • Page 45 Disk: 8 GB SATA, Solid State Networking: Realtek RTL8111, RJ45 Gigabit Ethernet Interface USB: 2 x USB 2.0 Video: Intel 4108 Graphics Processor, DVI- Power Consumption: 10 RUGGEDCOM RX1500PN LM APE1402W7 (Obso- Specifications Article Numbers lete) 6GK6015-0AL20-0GC0 (Standard) RUGGEDCOM RX1501 Installation Manual, 05/2020, C79000-G8976-1054-17...
  • Page 46 Operating System: 6GK6015-0AL20-0GG0 Debian Linux® and (Standard) CROSSBOW ADM 6GK6015-0AL20-0GG1 Processor: Intel Atom (Conformal Coated) E660T 1.3 GHz, 512 KB L2 Cache RAM: 2 GB DDR2, 800 MHz, 32-bit Disk: 16 GB SATA, Solid State RUGGEDCOM RX1501 Installation Manual, 05/2020, C79000-G8976-1054-17...
  • Page 47 Networking: Realtek RTL8111, RJ45 Gigabit Ethernet Interface USB: 2 x USB 2.0 Video: Intel 4108 Graphics Processor, DVI- Power Consumption: 10 RUGGEDCOM RX1501PN LM APE1808LNX Specifications Article Numbers Operating System: De- 6GK6015-0AL20-0GH0 bian Linux® (Standard) RUGGEDCOM RX1501 Installation Manual, 05/2020, C79000-G8976-1054-17...
  • Page 48 Maximum combined USB device power consumption is 500 mA at 5 V. Blank Modules RUGGEDCOM RX1500PN PS XXP Specifications Article Numbers — 6GK6015-0AL10-0AA0 (Standard) 6GK6015-0AL10-0AA1 (Conformal Coated) RUGGEDCOM RX1500PN LM Blank Specifications Article Numbers — 6GK6015-0AL20-0AA0 (Standard) 6GK6015-0AL20-0AA1 (Conformal Coated) RUGGEDCOM RX1501 Installation Manual, 05/2020, C79000-G8976-1054-17...
  • Page 49: Installing/Removing Line Modules

    Installing/Removing Line Modules Upon installing a new line module in the device, all features associated with the module are available in RUGGEDCOM RX1501 . For more information, refer to the RUGGEDCOM ROX Configuration Manual for the RUGGEDCOM RX1501. Once a line module is removed, all the features associated with the module are hid- den or disabled in RUGGEDCOM RX1501.
  • Page 50 Remove the current module from the slot. Insert the new module into the slot. Module Chassis Screw Figure 4.3 Installing a Module Tighten the screws to secure the module. [Optional] If necessary, install the device in the rack. RUGGEDCOM RX1501 Installation Manual, 05/2020, C79000-G8976-1054-17...
  • Page 51: Installing/Removing Power Modules

    All manuals and user guides at all-guides.com Modules 4.4 Installing/Removing Power Modules Installing/Removing Power Modules The RUGGEDCOM RX1501 supports a single power module. Power Module Figure 4.4 Power Module NOTICE Contamination hazard – risk of equipment damage Prevent the ingress of water, dirts and other debris that may lead to premature equipment failure.
  • Page 52 If applicable, connect the supplied terminal block to the module or connect the terminal block from the previous module. Confirm or connect the wiring from the power supply to the module. For more information, refer to "Connecting Power (Page 11)". RUGGEDCOM RX1501 Installation Manual, 05/2020, C79000-G8976-1054-17...
  • Page 53 Turn on power to the device and confirm the module is receiving and supplying power. This is indicated by the LEDs on the module. State Description Green The module is supplying power Green The module is receiving power RUGGEDCOM RX1501 Installation Manual, 05/2020, C79000-G8976-1054-17...
  • Page 54: Technical Specifications

    Rated Switching Current Isolation 30 VDC 2800 VDC for 1 minute be- 125 VDC 0.1 A , 0.15 A tween coil and contacts 250 VAC 6.25 A Inductive load R/L = 7 ms Resistive load RUGGEDCOM RX1501 Installation Manual, 05/2020, C79000-G8976-1054-17...
  • Page 55: Operating Environment

    IMPORTANT Temperature limits for select line modules may differ from that which can be with- stood by the RUGGEDCOM RX1501. Make sure the selected modules are rated for the expected environmental conditions before deployment. For more information, refer to the RUGGEDCOM RX1501 Series Modules Catalog.
  • Page 56 All manuals and user guides at all-guides.com Technical Specifications 5.5 Dimension Drawings 440.9 Figure 5.1 Overall Dimensions RUGGEDCOM RX1501 Installation Manual, 05/2020, C79000-G8976-1054-17...
  • Page 57 All manuals and user guides at all-guides.com Technical Specifications 5.5 Dimension Drawings 11.7 463.8 21.1 Figure 5.2 Rack Mount Dimensions 479.0 11.7 21.1 489.2 Figure 5.3 Panel and Din Rail Mount Dimensions RUGGEDCOM RX1501 Installation Manual, 05/2020, C79000-G8976-1054-17...
  • Page 58 All manuals and user guides at all-guides.com Technical Specifications 5.5 Dimension Drawings 162.5 151.4 19.7 Figure 5.4 Line Module Dimensions 162.5 151.8 40.6 Figure 5.5 Power Module Dimensions RUGGEDCOM RX1501 Installation Manual, 05/2020, C79000-G8976-1054-17...
  • Page 59 All manuals and user guides at all-guides.com Technical Specifications 5.5 Dimension Drawings RUGGEDCOM RX1501 Installation Manual, 05/2020, C79000-G8976-1054-17...
  • Page 60: Certification

    All manuals and user guides at all-guides.com Certification The RUGGEDCOM RX1501 device has been thoroughly tested to guarantee its confor- mance with recognized standards and has received approval from recognized regula- tory agencies. Note Certifications related to individual modules are detailed in the RUGGEDCOM Modules Catalog for the device available online.
  • Page 61: European Union (Eu)

    Certification 6.1.3 European Union (EU) 6.1.3 European Union (EU) This device is declared by Siemens AG to comply with essential requirements and other relevant provisions of the following EU directives: • Directive 2014/30/EU Directive 2014/30/EU of the European Parliament and of the Council of 26 Febru-...
  • Page 62: 6.1.4 Fcc

    The device is marked with a CE marking and notified body number, and can be used throughout the European community. 0680 A copy of the CE Declaration of Conformity is available from Siemens AG. For contact information, refer to "Contacting Siemens (Page vii)".
  • Page 63: Acma

    6.1.8 RoHS This device is declared by Siemens AG to meet the requirements of the following Ro- HS (Restriction of Hazardous Substances) directives for the restricted use of certain hazardous substances in electrical and electronic equipment: •...
  • Page 64: Emc And Environmental Type Tests

    IEC 61850-3 • Communication Networks and Systems in Substations – Part 3: General Require- ments EMC and Environmental Type Tests The RUGGEDCOM RX1501 has passed the following Electromagnetic Compatibility (EMC) and environmental tests. EMC Type Test for IEC 61850-3 Test Description...
  • Page 65 EMC Immunity Type Tests for IEEE 1613 Note The RUGGEDCOM RX1501 meets Class 2 requirements for an all-fiber configuration and Class 1 requirements for copper ports. Class 1 allows for temporary communica- tion loss, while Class 2 requires error-free and interrupted communications.
  • Page 66 Class 1 IEC 61373 Long Life (Random Vibration) Category 1 Class B   Shock   IEC 60255-21-3 Seismic Method A Level 2 MIL-STD-810G Altitude 12192 m (40000 ft)   @ 40 °C, 90 minutes RUGGEDCOM RX1501 Installation Manual, 05/2020, C79000-G8976-1054-17...
  • Page 67 All manuals and user guides at all-guides.com Certification 6.2 EMC and Environmental Type Tests RUGGEDCOM RX1501 Installation Manual, 05/2020, C79000-G8976-1054-17...
  • Page 68 All manuals and user guides at all-guides.com Further Information Siemens RUGGEDCOM https://www.siemens.com/ruggedcom Industry Online Support (service and support) https://support.industry.siemens.com Industry Mall https://mall.industry.siemens.com Siemens AG Digital Industry Process Automation Postfach 48 48 90026 NÜRNBERG GERMANY...

Table of Contents