Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommend- ed or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
All manuals and user guides at all-guides.com Preface This guide describes the RUGGEDCOM RX1501. It describes the major features of the device, installation, commissioning and important technical specifications. It is intended for use by network technical support personnel who are responsible for the installation, commissioning and maintenance of the device.
Warranty Warranty Siemens warrants this product for a period of five (5) years from the date of pur- chase, conditional upon the return to factory for maintenance during the warranty term. This product contains no user-serviceable parts. Attempted service by unautho- rized personnel shall render all warranties null and void.
Call a local hotline center to submit a Support Request (SR). To locate a lo- cal hotline center, visit https://w3.siemens.com/aspa_app/?lang=en. Mobile App Install the Industry Online Support app by Siemens AG on any Android, Apple iOS or Windows mobile device and be able to: •...
Page 9
All manuals and user guides at all-guides.com Preface Contacting Siemens viii RUGGEDCOM RX1501 Installation Manual, 05/2020, C79000-G8976-1054-17...
(EMI) and heavy electrical surges typical of the harsh environ- ments found in many industrial applications. An operating temperature range of -40 to 85 °C (-40 to 185 °F) allows the RUGGEDCOM RX1501 to be placed in almost any location.
Page 11
Device (Page 21)". Utility USB Port Use the USB port to upgrade the RUGGEDCOM RX1501 software or install files, such as configuration files and feature key files. For more information, refer to the RUGGEDCOM ROX Configuration Manual for the RUGGEDCOM RX1501.
All manuals and user guides at all-guides.com Introduction 1.3 Required Tools and Materials Required Tools and Materials The following tools and materials are required to install the RUGGEDCOM RX1501: Tools/Materials Purpose AC/DC power cord (16 AWG) For connecting power to the device.
Siemens also does not recommend using copper Ethernet ports to interface with de- vices in the field across distances that could produce high levels of ground potential rise (i.e.
This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by Siemens AG could invalidate specifications, test results, and agency approvals, and void the user's authority to operate the equipment.
Inspect the package for damage before opening it. Visually inspect each item in the package for any physical damage. Verify all items are included. NOTICE If any item is missing or damaged, contact Siemens for assistance. RUGGEDCOM RX1501 Installation Manual, 05/2020, C79000-G8976-1054-17...
"Dimension Drawings (Page 46)". 2.3.1 Mounting the Device to a Rack For rack mount installations, the RUGGEDCOM RX1501 can be equipped with rack mount adapters pre-installed at the front or rear of the chassis. Additional adapters are provided for added stability. NOTICE Vibration hazard –...
2.3.2 Mounting the Device on a DIN Rail For DIN rail installations, the RUGGEDCOM RX1501 can be equipped with panel/DIN rail adapters pre-installed on each side of the chassis. The adapters allow the device to be slid onto a standard 35 mm (1.4 in) DIN rail.
2.3.3 Mounting the Device to a Panel For panel installations, the RUGGEDCOM RX1501 can be equipped with panel/DIN rail adapters pre-installed on each side of the chassis. The adapters allow the device to be attached to a panel using screws.
NO contact and closes the NC (Normally Closed) contact. Note Control of the failsafe relay output is configurable through RUGGEDCOM RX1501 . One common application for this relay is to signal an alarm if a power failure occurs.
Figure 2.4 Failsafe Alarm Relay Wiring Connecting Power The RUGGEDCOM RX1501 supports a single high AC, high DC or low DC power mod- ule. Power modules can be equipped with either a screw or European-style (Euroblock) terminal block. The screw terminal block is installed using Phillips screws and com- pression plates, allowing either bare wire connections or crimped terminal lugs.
NOTICE Electrical hazard – risk of damage to equipment Do not connect AC power cables to a 12, 24 or 48 VDC power supply terminal block. Damage to the power supply may occur. RUGGEDCOM RX1501 Installation Manual, 05/2020, C79000-G8976-1054-17...
Page 22
Ground Terminal Negative/Neutral (-/N) Terminal Figure 2.5 AC Terminal Block Wiring – European-style (Euroblock) Terminal Block for HIP Power Supplies Not Connected Removable Screw Terminal Block Non-removable Screw Terminal Block Positive/Live (+/L) Terminal Ground Terminal RUGGEDCOM RX1501 Installation Manual, 05/2020, C79000-G8976-1054-17...
Page 23
For screw terminal blocks, install the safety cover. Screw Safety Cover Screw Terminal Block RUGGEDCOM RX1501 Device Figure 2.7 Assembling the Safety Cover Using a braided wire or other appropriate grounding wire, connect the ground terminal to the chassis ground connection.
Do not connect AC power cables to a 12, 24 or 48 VDC power supply terminal block. Damage to the power supply may occur. Note The RUGGEDCOM RX1501 works with both positive VDC power supplies and negative VDC power supplies. RUGGEDCOM RX1501...
Page 25
Ground Terminal Figure 2.9 DC Terminal Block Wiring – European-style (Euroblock) Terminal Block for 12P, 24P and 48P Power Supplies Not Connected Removable Screw Terminal Block Non-removable Screw Terminal Block Positive (+) Terminal Negative (-) Terminal RUGGEDCOM RX1501 Installation Manual, 05/2020, C79000-G8976-1054-17...
Page 26
Negative (-) Terminal Ground Terminal Figure 2.11 DC Terminal Block Wiring – European-style (Euroblock) Terminal Block for -12P, -24P and -48P Power Supplies Not Connected Removable Screw Terminal Block Non-removable Screw Terminal Block Positive (+) Terminal RUGGEDCOM RX1501 Installation Manual, 05/2020, C79000-G8976-1054-17...
Page 27
Connect the negative wire from the power source to the negative (-) terminal on the terminal block. For screw terminal blocks, install the safety cover. Screw Safety Cover Screw Terminal Block RUGGEDCOM RX1501 Device Figure 2.13 Assembling the Safety Cover RUGGEDCOM RX1501 Installation Manual, 05/2020, C79000-G8976-1054-17...
Page 28
#10 Ring Lug #10-32 Screw Connection from External Power Source Ground Connection Figure 2.14 Ground Connection Install the safety cover over the terminal block. This is mandatory for 48 VDC and -48 VDC power supplies. RUGGEDCOM RX1501 Installation Manual, 05/2020, C79000-G8976-1054-17...
Page 29
All manuals and user guides at all-guides.com Installing the Device 2.5.2 Connecting Low DC Power RUGGEDCOM RX1501 Installation Manual, 05/2020, C79000-G8976-1054-17...
This section describes how to connect to and manage the device. Connecting to the Device The following describes the various methods for accessing the RUGGEDCOM RX1501 console and Web interfaces on the device. For more detailed instructions, refer to the RUGGEDCOM ROX Configuration Manual for the RUGGEDCOM RX1501.
Communication Ports Connect any of the available Ethernet ports on the device to a management switch and access the RUGGEDCOM RX1501 console and Web interfaces via the device's IP address. The factory default IP address for the RUGGEDCOM RX1501 is https://- 192.168.0.2.
Page 32
The following will void the warranty and potentially result in configuration data cor- ruption/loss: • Using a CF card not approved by Siemens for use with this device • Removing the CF card in any scenario other than those described in this section...
Page 33
CompactFlash Card Access Panel Figure 3.4 Removing the CF Card Press the ejector button to the left of the CF card and then pull the card out. Secure the CF card access panel to the chassis. RUGGEDCOM RX1501 Installation Manual, 05/2020, C79000-G8976-1054-17...
All manuals and user guides at all-guides.com Modules The RUGGEDCOM RX1501 features slots for up to four field-replaceable line modules, which can be used to expand and customize the capabilities of the device to suit spe- cific applications. A variety of modules are available, each featuring a specific type of communica- tion port: copper Ethernet, fiber optic Ethernet, SFP, WAN, cellular modem and DDS.
The following is a list of all power and line modules available for use in the RUGGED- COM RX1501. For more information about individual modules, refer to the RUGGED- COM RX1500 Series Modules Catalog [https://support.industry.siemens.com/cs/ca/- en/view/109747072]. RUGGEDCOM RX1501 Installation Manual, 05/2020, C79000-G8976-1054-17...
Installing/Removing Line Modules Upon installing a new line module in the device, all features associated with the module are available in RUGGEDCOM RX1501 . For more information, refer to the RUGGEDCOM ROX Configuration Manual for the RUGGEDCOM RX1501. Once a line module is removed, all the features associated with the module are hid- den or disabled in RUGGEDCOM RX1501.
Page 50
Remove the current module from the slot. Insert the new module into the slot. Module Chassis Screw Figure 4.3 Installing a Module Tighten the screws to secure the module. [Optional] If necessary, install the device in the rack. RUGGEDCOM RX1501 Installation Manual, 05/2020, C79000-G8976-1054-17...
All manuals and user guides at all-guides.com Modules 4.4 Installing/Removing Power Modules Installing/Removing Power Modules The RUGGEDCOM RX1501 supports a single power module. Power Module Figure 4.4 Power Module NOTICE Contamination hazard – risk of equipment damage Prevent the ingress of water, dirts and other debris that may lead to premature equipment failure.
Page 52
If applicable, connect the supplied terminal block to the module or connect the terminal block from the previous module. Confirm or connect the wiring from the power supply to the module. For more information, refer to "Connecting Power (Page 11)". RUGGEDCOM RX1501 Installation Manual, 05/2020, C79000-G8976-1054-17...
Page 53
Turn on power to the device and confirm the module is receiving and supplying power. This is indicated by the LEDs on the module. State Description Green The module is supplying power Green The module is receiving power RUGGEDCOM RX1501 Installation Manual, 05/2020, C79000-G8976-1054-17...
IMPORTANT Temperature limits for select line modules may differ from that which can be with- stood by the RUGGEDCOM RX1501. Make sure the selected modules are rated for the expected environmental conditions before deployment. For more information, refer to the RUGGEDCOM RX1501 Series Modules Catalog.
Page 56
All manuals and user guides at all-guides.com Technical Specifications 5.5 Dimension Drawings 440.9 Figure 5.1 Overall Dimensions RUGGEDCOM RX1501 Installation Manual, 05/2020, C79000-G8976-1054-17...
Page 57
All manuals and user guides at all-guides.com Technical Specifications 5.5 Dimension Drawings 11.7 463.8 21.1 Figure 5.2 Rack Mount Dimensions 479.0 11.7 21.1 489.2 Figure 5.3 Panel and Din Rail Mount Dimensions RUGGEDCOM RX1501 Installation Manual, 05/2020, C79000-G8976-1054-17...
Page 58
All manuals and user guides at all-guides.com Technical Specifications 5.5 Dimension Drawings 162.5 151.4 19.7 Figure 5.4 Line Module Dimensions 162.5 151.8 40.6 Figure 5.5 Power Module Dimensions RUGGEDCOM RX1501 Installation Manual, 05/2020, C79000-G8976-1054-17...
Page 59
All manuals and user guides at all-guides.com Technical Specifications 5.5 Dimension Drawings RUGGEDCOM RX1501 Installation Manual, 05/2020, C79000-G8976-1054-17...
All manuals and user guides at all-guides.com Certification The RUGGEDCOM RX1501 device has been thoroughly tested to guarantee its confor- mance with recognized standards and has received approval from recognized regula- tory agencies. Note Certifications related to individual modules are detailed in the RUGGEDCOM Modules Catalog for the device available online.
Certification 6.1.3 European Union (EU) 6.1.3 European Union (EU) This device is declared by Siemens AG to comply with essential requirements and other relevant provisions of the following EU directives: • Directive 2014/30/EU Directive 2014/30/EU of the European Parliament and of the Council of 26 Febru-...
The device is marked with a CE marking and notified body number, and can be used throughout the European community. 0680 A copy of the CE Declaration of Conformity is available from Siemens AG. For contact information, refer to "Contacting Siemens (Page vii)".
6.1.8 RoHS This device is declared by Siemens AG to meet the requirements of the following Ro- HS (Restriction of Hazardous Substances) directives for the restricted use of certain hazardous substances in electrical and electronic equipment: •...
IEC 61850-3 • Communication Networks and Systems in Substations – Part 3: General Require- ments EMC and Environmental Type Tests The RUGGEDCOM RX1501 has passed the following Electromagnetic Compatibility (EMC) and environmental tests. EMC Type Test for IEC 61850-3 Test Description...
Page 65
EMC Immunity Type Tests for IEEE 1613 Note The RUGGEDCOM RX1501 meets Class 2 requirements for an all-fiber configuration and Class 1 requirements for copper ports. Class 1 allows for temporary communica- tion loss, while Class 2 requires error-free and interrupted communications.
Page 66
Class 1 IEC 61373 Long Life (Random Vibration) Category 1 Class B Shock IEC 60255-21-3 Seismic Method A Level 2 MIL-STD-810G Altitude 12192 m (40000 ft) @ 40 °C, 90 minutes RUGGEDCOM RX1501 Installation Manual, 05/2020, C79000-G8976-1054-17...
Page 67
All manuals and user guides at all-guides.com Certification 6.2 EMC and Environmental Type Tests RUGGEDCOM RX1501 Installation Manual, 05/2020, C79000-G8976-1054-17...
Page 68
All manuals and user guides at all-guides.com Further Information Siemens RUGGEDCOM https://www.siemens.com/ruggedcom Industry Online Support (service and support) https://support.industry.siemens.com Industry Mall https://mall.industry.siemens.com Siemens AG Digital Industry Process Automation Postfach 48 48 90026 NÜRNBERG GERMANY...