hit counter script
Siemens RUGGEDCOM RX1511 Installation Manual

Siemens RUGGEDCOM RX1511 Installation Manual

Simatic net
Hide thumbs Also See for RUGGEDCOM RX1511:

Advertisement

Quick Links

Installation Manual
SIMATIC NET
Industrial Ethernet Switches
RUGGEDCOM RX1511
Edition
07/2019
https://www.siemens.com

Advertisement

Table of Contents
loading

Summary of Contents for Siemens RUGGEDCOM RX1511

  • Page 1 Installation Manual SIMATIC NET Industrial Ethernet Switches RUGGEDCOM RX1511 Edition 07/2019 https://www.siemens.com...
  • Page 2 Preface Introduction Installing the Device SIMATIC NET Device Management Industrial Ethernet Switches RUGGEDCOM RX1511 Modules Technical Specifications Installation Manual Certification 07/2019 C79000-G8976-1056...
  • Page 3 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommend- ed or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 4: Table Of Contents

    Disclaimer of Liability ......................v Registered Trademarks ......................vi Warranty ..........................vi Training ..........................vi Customer Support ........................vii Contacting Siemens ....................... vii Introduction ........................... 1 Feature Highlights ....................1 Description ......................1 Required Tools and Materials ................. 3 Decommissioning and Disposal ................3 Cabling Recommendations ..................
  • Page 5 6.1.2 European Union (EU) ..................47 6.1.3 FCC ........................49 6.1.4 FDA/CDRH ......................49 6.1.5 ISED ........................49 6.1.6 RoHS ........................49 6.1.7 Other Approvals ....................50 EMC and Environmental Type Tests ..............50 RUGGEDCOM RX1511 Installation Manual, 07/2019, C79000-G8976-1056...
  • Page 6: Preface

    However, deviations between the product and the documentation may exist. Siemens shall not be liable for any errors or omissions contained herein or for conse- quential damages in connection with the furnishing, performance, or use of this ma- terial.
  • Page 7: Registered Trademarks

    Warranty Siemens warrants this product for a period of five (5) years from the date of pur- chase, conditional upon the return to factory for maintenance during the warranty term.
  • Page 8: Customer Support

    Preface Customer Support Customer Support Customer support is available 24 hours, 7 days a week for all Siemens customers. For technical support or general information, contact Siemens Customer Support through any of the following methods: Online Visit http://www.siemens.com/automation/support-request to submit a Support Request (SR) or check on the status of an existing SR.
  • Page 9 Preface Contacting Siemens viii RUGGEDCOM RX1511 Installation Manual, 07/2019, C79000-G8976-1056...
  • Page 10: Introduction

    (EMI) and heavy electrical surges typical of the harsh environ- ments found in many industrial applications. An operating temperature range of -40 to 85 °C (-40 to 185 °F) allows the RUGGEDCOM RX1511 to be placed in almost any location.
  • Page 11 Device (Page 19)". Utility USB Port Use the USB port to upgrade the RUGGEDCOM RX1511 software or install files, such as configuration files and feature key files. For more information, refer to the RUGGEDCOM RUGGEDCOM RX1511 User Guide for the RUGGEDCOM RX1511.
  • Page 12: Required Tools And Materials

    For more informa- tion, refer to "Accessing the CompactFlash Card (Page 20)". Required Tools and Materials The following tools and materials are required to install the RUGGEDCOM RX1511: Tools/Materials Purpose AC/DC power cord (16 AWG) For connecting power to the device.
  • Page 13: Cabling Recommendations

    Siemens also does not recommend using copper Ethernet ports to interface with de- vices in the field across distances that could produce high levels of ground potential rise (i.e.
  • Page 14: Installing The Device

    This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by Siemens AG could invalidate specifications, test results, and agency approvals, and void the user's authority to operate the equipment.
  • Page 15: General Procedure

    If any item is missing or damaged, contact Siemens for assistance. Mounting the Device The RUGGEDCOM RX1511 is designed for maximum mounting and display flexibility. It can be equipped with connectors that allow it to be installed in a 35 mm (1.4 in) DIN rail, or directly on a panel.
  • Page 16: 2.3.1 Mounting The Device On A Din Rail

    2.3.1 Mounting the Device on a DIN Rail For DIN rail installations, the RUGGEDCOM RX1511 can be equipped with panel/DIN rail adapters pre-installed on each side of the chassis. The adapters allow the device to be slid onto a standard 35 mm (1.4 in) DIN rail.
  • Page 17: 2.3.2 Mounting The Device To A Panel

    2.3.2 Mounting the Device to a Panel For panel installations, the RUGGEDCOM RX1511 can be equipped with panel/DIN rail adapters pre-installed on each side of the chassis. The adapters allow the device to be attached to a panel using screws.
  • Page 18: Connecting Power

    Figure 2.3 Failsafe Alarm Relay Wiring Connecting Power The RUGGEDCOM RX1511 supports a single high AC, high DC or low DC power mod- ule. Power modules can be equipped with either a screw or European-style (Euroblock) terminal block. The screw terminal block is installed using Phillips screws and com- pression plates, allowing either bare wire connections or crimped terminal lugs.
  • Page 19: 2.5.1 Connecting High Ac/Dc Power

    Damage to the power supply may occur. Note The screw terminal block is installed using Phillips screws and compression plates, al- lowing either bare wire connections or crimped terminal lugs. Use #6 size ring lugs for secure, reliable connections. RUGGEDCOM RX1511 Installation Manual, 07/2019, C79000-G8976-1056...
  • Page 20 AC Terminal Block Wiring – European-style (Euroblock) Terminal Block for HIP Power Supplies Not Connected Removable Screw Terminal Block Non-removable Screw Terminal Block Positive/Live (+/L) Terminal Ground Terminal Negative/Neutral (-/N) Terminal Figure 2.5 AC Terminal Block Wiring – Screw Terminal Block for HI Power Supplies RUGGEDCOM RX1511 Installation Manual, 07/2019, C79000-G8976-1056...
  • Page 21 For screw terminal blocks, install the safety cover. Screw Safety Cover Screw Terminal Block RUGGEDCOM RX1511 Device Figure 2.6 Assembling the Safety Cover Using a braided wire or other appropriate grounding wire, connect the ground terminal to the chassis ground connection.
  • Page 22: 2.5.2 Connecting Low Dc Power

    Do not connect AC power cables to a 12, 24 or 48 VDC power supply terminal block. Damage to the power supply may occur. Note The RUGGEDCOM RX1511 works with both positive VDC power supplies and negative VDC power supplies. Note The screw terminal block is installed using Phillips screws and compression plates, al- lowing either bare wire connections or crimped terminal lugs.
  • Page 23 Ground Terminal Figure 2.8 DC Terminal Block Wiring – European-style (Euroblock) Terminal Block for 12P, 24P and 48P Power Supplies Not Connected Removable Screw Terminal Block Non-removable Screw Terminal Block Positive (+) Terminal Negative (-) Terminal RUGGEDCOM RX1511 Installation Manual, 07/2019, C79000-G8976-1056...
  • Page 24 Positive (+) Terminal Negative (-) Terminal Ground Terminal Figure 2.10 DC Terminal Block Wiring – European-style (Euroblock) Terminal Block for -12P, -24P and -48P Power Supplies Not Connected Removable Screw Terminal Block Non-removable Screw Terminal Block RUGGEDCOM RX1511 Installation Manual, 07/2019, C79000-G8976-1056...
  • Page 25 Connect the negative wire from the power source to the negative (-) terminal on the terminal block. For screw terminal blocks, install the safety cover. Screw Safety Cover Screw Terminal Block RUGGEDCOM RX1511 Device Figure 2.12 Assembling the Safety Cover RUGGEDCOM RX1511 Installation Manual, 07/2019, C79000-G8976-1056...
  • Page 26 #10 Ring Lug #10-32 Screw Connection from External Power Source Ground Connection Figure 2.13 Ground Connection Install the safety cover over the terminal block. This is mandatory for 48 VDC and -48 VDC power supplies. RUGGEDCOM RX1511 Installation Manual, 07/2019, C79000-G8976-1056...
  • Page 27 Installing the Device 2.5.2 Connecting Low DC Power RUGGEDCOM RX1511 Installation Manual, 07/2019, C79000-G8976-1056...
  • Page 28: Device Management

    This section describes how to connect to and manage the device. Connecting to the Device The following describes the various methods for accessing the RUGGEDCOM RX1511 console and Web interfaces on the device. For more detailed instructions, refer to the RUGGEDCOM ROX User Guide for the RUGGEDCOM RX1511.
  • Page 29: Configuring The Device

    Communication Ports Connect any of the available Ethernet ports on the device to a management switch and access the RUGGEDCOM RX1511 console and Web interfaces via the device's IP address. The factory default IP address for the RUGGEDCOM RX1511 is https://- 192.168.0.2.
  • Page 30 Configuration hazard – risk of data corruption/loss. The following will void the war- ranty and potentially result in configuration data corruption/loss: • Using a CF card not approved by Siemens for use with this device • Removing the CF card in any scenario other than those described in this section...
  • Page 31 Inserting the CF Card Secure the CF card access panel to the chassis. Removing the CF card To remove the CF card from the device, do the following: Make sure the device is powered down. RUGGEDCOM RX1511 Installation Manual, 07/2019, C79000-G8976-1056...
  • Page 32 CompactFlash Card Access Panel Figure 3.4 Removing the CF Card Press the ejector button to the left of the CF card and then pull the card out. Secure the CF card access panel to the chassis. RUGGEDCOM RX1511 Installation Manual, 07/2019, C79000-G8976-1056...
  • Page 33 Device Management 3.3 Accessing the CompactFlash Card RUGGEDCOM RX1511 Installation Manual, 07/2019, C79000-G8976-1056...
  • Page 34: Modules

    Modules The RUGGEDCOM RX1511 features slots for up to two field-replaceable line modules, which can be used to expand and customize the capabilities of the device to suit spe- cific applications. A variety of modules are available, each featuring a specific type of communication port: copper Ethernet, fiber optic Ethernet, SFP, WAN, cellular mo- dem and DDS.
  • Page 35 Input Range: 36 to 72 6GK6015-0AL12-0AA0 (Standard) Terminal Type: Remov- 6GK6015-0AL12-0AA1 able Screw (Conformal Coated) RUGGEDCOM RX1500PN PS 48P Specifications Article Numbers Input Range: 36 to 72 6GK6015-0AL15-0AA0 (Standard) Terminal Type: Euro- 6GK6015-0AL15-0AA1 pean-style (Euroblock) (Conformal Coated) RUGGEDCOM RX1511 Installation Manual, 07/2019, C79000-G8976-1056...
  • Page 36 (Conformal Coated) Port Type: M12 (8-Pin, A-Coded) Distance: 100 m (328 ft) Power Consumption: 4 RUGGEDCOM RX1500PN LM CG03B Specifications Article Numbers Ports: 2 6GK6015-0AL20-0PE0 (Standard) Speed: 1000 Mbps 6GK6015-0AL20-0PE1 Interface: TX (Conformal Coated) RUGGEDCOM RX1511 Installation Manual, 07/2019, C79000-G8976-1056...
  • Page 37 Speed: 100 Mbps 6GK6015-0AL20-0PF1 Interface: TX (Conformal Coated) Port Type: M12 (8-Pin, A-Coded, Controlled By- pass) Distance: 100 m (328 ft) Power Consumption: 5 RUGGEDCOM RX1500PN LM 4TX04 Specifications Article Numbers Ports: 4 6GK6015-0AL20-0PD0 (Standard) RUGGEDCOM RX1511 Installation Manual, 07/2019, C79000-G8976-1056...
  • Page 38 Distance: 2 km (1.2 mi) Power Consumption: 5 RUGGEDCOM RX1500PN LM FL01 Specifications Article Numbers Mode: MM 6GK6015-0AL20-0BD0 (Standard) Speed: 10/100 Mbps 6GK6015-0AL20-0BD1 Interface: FL/SX (Conformal Coated) Wavelength: 820 nm Ports: 3 Port Type: ST RUGGEDCOM RX1511 Installation Manual, 07/2019, C79000-G8976-1056...
  • Page 39 Ports: 6 6GK6015-0AL20-0KB1 Port Type: RJ45 (Conformal Coated) Power Consumption: 3 RUGGEDCOM RX1500PN LM TC1 Specifications Article Numbers (Stan- dard) Interface: T1/E1 6GK6015-0AL20-0MB0 Ports: 1 (Standard) Port Type: RJ48C 6GK6015-0AL20-0MB1 Power Consumption: 3 (Conformal Coated) RUGGEDCOM RX1511 Installation Manual, 07/2019, C79000-G8976-1056...
  • Page 40 Port Type: 50 Ω SMA Antennas: 1 x GSM/ EDGE/HSPA+, 1 x Re- ceive Diversity (Se- condary) SIM: Dual Mini-SIM (2FF) Power Consumption: 7 RUGGEDCOM RX1500PN LM W12 Specifications Article Numbers (Stan- dard) Services: GSM/EDGE/HS- 6GK6015-0AL20-0WC0 (Standard) RUGGEDCOM RX1511 Installation Manual, 07/2019, C79000-G8976-1056...
  • Page 41 Region: North America (Standard) (Verizon) 6GK6015-0AL20-0WF1 Port Type: 50 Ω SMA (Conformal Coated) Antennas: 1 x GSM/ EDGE/HSPA+, 1 x EVDO Rev A, 2 x Receive Diver- sity (Secondary) SIM: Dual Mini-SIM (2FF) Power Consumption: 7 RUGGEDCOM RX1511 Installation Manual, 07/2019, C79000-G8976-1056...
  • Page 42 1 x LTE MIMO, 1 x GPS SIM: Dual Mini-SIM (2FF) Power Consumption: 7 RUGGEDCOM RX1500PN LM W81 Specifications Article Numbers (Stan- dard) Services: 4G LTE/HSPA+/ EDGE/GPRS/GSM/UMTS/ 6GK60150AL200WK0 GNSS (Standard) Region: Asia-Pacific 6GK60150AL200WK1 (Conformal Coated) Port Type: 50 Ω SMA RUGGEDCOM RX1511 Installation Manual, 07/2019, C79000-G8976-1056...
  • Page 43 Disk: 8 GB SATA, Solid State Networking: Realtek RTL8111, RJ45 Gigabit Ethernet Interface USB: 2 x USB 2.0 Video: Intel 4108 Graphics Processor, DVI- Power Consumption: 10 RUGGEDCOM RX1500PN LM APE1404 Specifications Article Numbers (Stan- dard) RUGGEDCOM RX1511 Installation Manual, 07/2019, C79000-G8976-1056...
  • Page 44 (Standard) Processor: Intel Atom E660T 1.3 GHz, 512 KB 6GK6015-0AL20-0GF1 L2 Cache (Conformal Coated) RAM: 2 GB DDR2, 800 MHz, 32-bit Disk: 16 GB SATA, Solid State Networking: Realtek RTL8111, RJ45 Gigabit Ethernet Interface RUGGEDCOM RX1511 Installation Manual, 07/2019, C79000-G8976-1056...
  • Page 45 Video: Intel HD Graphics Processor, Display Port Power Consumption: 12 Maximum combined USB device power consumption is 500 mA at 5 V. Blank Modules RUGGEDCOM RX1500PN PS XXP Specifications Article Numbers — 6GK6015-0AL10-0AA0 (Standard) RUGGEDCOM RX1511 Installation Manual, 07/2019, C79000-G8976-1056...
  • Page 46: Installing/Removing Line Modules

    Installing/Removing Line Modules Upon installing a new line module in the device, all features associated with the module are available in RUGGEDCOM RX1511. For more information, refer to the RUGGEDCOM ROX User Guide for the RUGGEDCOM RX1511. Once a line module is removed, all the features associated with the module are hid- den or disabled in RUGGEDCOM RX1511.
  • Page 47 [Optional] If necessary, install the device in the rack. Installing a Module To install a line module, do the following: [Optional] If the device is installed in a rack, remove it from the rack. Remove the current module from the slot. RUGGEDCOM RX1511 Installation Manual, 07/2019, C79000-G8976-1056...
  • Page 48: Installing/Removing Power Modules

    Figure 4.3 Installing a Module Tighten the screws to secure the module. [Optional] If necessary, install the device in the rack. Installing/Removing Power Modules The RUGGEDCOM RX1511 supports a single power module. Power Module Figure 4.4 Power Module RUGGEDCOM RX1511 Installation Manual, 07/2019, C79000-G8976-1056...
  • Page 49 Install a new or blank module to prevent the ingress of dust and dirt. RUGGEDCOM RX1511 Installation Manual, 07/2019, C79000-G8976-1056...
  • Page 50 Turn on power to the device and confirm the module is receiving and supplying power. This is indicated by the LEDs on the module. State Description Green The module is supplying power Green The module is receiving power RUGGEDCOM RX1511 Installation Manual, 07/2019, C79000-G8976-1056...
  • Page 51 Modules 4.3 Installing/Removing Power Modules RUGGEDCOM RX1511 Installation Manual, 07/2019, C79000-G8976-1056...
  • Page 52: Technical Specifications

    15 VDC 12 A 67 W 2121 VDC for 1 minute Power consumption varies based on the device configuration. A typical RUGGEDCOM RX1511 chassis will consume approximately 35 W of power. (T) denotes time-delay fuse. Failsafe Relay Specifications Maximum Switching Voltage...
  • Page 53: Operating Environment

    NOTICE Temperature limits for select line modules may differ from that which can be with- stood by the RUGGEDCOM RX1511. Make sure the selected modules are rated for the expected environmental conditions before deployment. For more information, refer to the RUGGEDCOM RX1511 Series Modules Catalog.
  • Page 54 Technical Specifications 5.5 Dimension Drawings 199.6 122.7 Figure 5.1 Overall Dimensions 199.9 152.4 189.8 78.2 Figure 5.2 Panel and Din Rail Mount Dimensions RUGGEDCOM RX1511 Installation Manual, 07/2019, C79000-G8976-1056...
  • Page 55 Technical Specifications 5.5 Dimension Drawings 162.5 151.4 19.7 Figure 5.3 Line Module Dimensions 162.5 151.8 40.6 Figure 5.4 Power Module Dimensions RUGGEDCOM RX1511 Installation Manual, 07/2019, C79000-G8976-1056...
  • Page 56: Certification

    Certification The RUGGEDCOM RX1511 device has been thoroughly tested to guarantee its confor- mance with recognized standards and has received approval from recognized regula- tory agencies. Note Certifications related to individual modules are detailed in the RUGGEDCOM Modules Catalog for the device available online.
  • Page 57 The device is marked with a CE marking and notified body number, and can be used throughout the European community. 0680 A copy of the CE Declaration of Conformity is available from Siemens AG. For contact information, refer to "Contacting Siemens (Page vii)".
  • Page 58: Fcc

    CAN ICES-3 (A)/NMB-3 (A) 6.1.6 RoHS This device is declared by Siemens AG to meet the requirements of the following Ro- HS (Restriction of Hazardous Substances) directives for the restricted use of certain hazardous substances in electrical and electronic equipment: •...
  • Page 59: 6.1.7 Other Approvals

    IEC 61850-3 Communication Networks and Systems in Substations – Part 3: General Require- ments EMC and Environmental Type Tests The RUGGEDCOM RX1511 has passed the following Electromagnetic Compatibility (EMC) and environmental tests. EMC Type Test for IEC 61850-3 Test Description...
  • Page 60 EMC Immunity Type Tests for IEEE 1613 Note The RUGGEDCOM RX1511 meets Class 2 requirements for an all-fiber configuration and Class 1 requirements for copper ports. Class 1 allows for temporary communica- tion loss, while Class 2 requires error-free and interrupted communications.
  • Page 61 IEC 60255-21-1 Vibration 2 g @ 10-150 Hz Class 2 IEC 60255-21-2 Shock 30 g @ 11 ms Class 2 Bump 10 g @ 16 ms Class 1 IEC 60255-21-3 Seismic Method A Level 2 RUGGEDCOM RX1511 Installation Manual, 07/2019, C79000-G8976-1056...
  • Page 62 Further Information Siemens https://www.siemens.com Industry Online Support (service and support) https://support.industry.siemens.com Industry Mall https://mall.industry.siemens.com Siemens AG Digital Industry Process Automation Postfach 48 48 90026 NÜRNBERG GERMANY...

Table of Contents