Sign In
Upload
Manuals
Brands
Mitsubishi Electric Manuals
Inverter
FR-D720S-100
Mitsubishi Electric FR-D720S-100 Manuals
Manuals and User Guides for Mitsubishi Electric FR-D720S-100. We have
2
Mitsubishi Electric FR-D720S-100 manuals available for free PDF download: Instruction Manual, Installation Manuallines
Mitsubishi Electric FR-D720S-100 Instruction Manual (296 pages)
Brand:
Mitsubishi Electric
| Category:
Inverter
| Size: 16.8 MB
Table of Contents
Instruction Manual
1
Table of Contents
5
1 Outline
13
Product Checking and Parts Identification
13
Inverter and Peripheral Devices
14
Specifications
14
Peripheral Devices
15
Removal and Reinstallation of the Cover
16
Front Cover
16
Wiring Cover
18
Wiring
18
Installation of the Inverter and Enclosure Design
19
Inverter Installation Environment
19
Cooling System Types for Inverter Enclosure
21
Inverter Placement
22
2 Wiring
24
Terminal Connection Diagram
25
Main Circuit Terminal Specifications
26
Specification of Main Circuit Terminal
26
Terminal Arrangement of the Main Circuit Terminal, Power Supply and the Motor Wiring
26
Cables and Wiring Length
28
Main Circuit Terminal Specifications
29
Control Circuit Specifications
31
Control Circuit Terminal
31
Changing the Control Logic
33
Connection of Stand-Alone Option Unit
34
Wiring of Control Circuit
35
Wiring Instructions
38
Connection to the PU Connector
39
Connection of Stand-Alone Option Unit
41
(MRS Type, MYS Type, FR-ABR) (FR-D720-025 or More, FR-D740-012 or More, FR
41
Connection of the Brake Unit (FR-BU2)
43
Connection of the High Power Factor Converter (FR-HC)
44
Connection of the Power Regeneration Common Converter (FR-CV)
45
Connection of a DC Reactor (FR-HEL)
45
3 Precautions for Use of the Inverter
46
EMC and Leakage Currents
47
Leakage Currents and Countermeasures
47
Inverter-Driven 400V Class Motor
47
EMC Measures
49
Power Supply Harmonics
51
Installation of Power Factor Improving Reactor
52
Power-Off and Magnetic Contactor (MC)
53
Inverter-Driven 400V Class Motor
54
Precautions for Use of the Inverter
55
Failsafe of the System Which Uses the Inverter
57
4 Parameters
60
Operation Panel
61
Names and Functions of the Operation Panel
61
Basic Operation (Factory Setting)
62
Easy Operation Mode Setting (Easy Setting Mode)
63
Change the Parameter Setting Value
64
Setting Dial Push
64
Parameter List
65
Adjust the Output Torque (Current) of the Motor
75
Manual Torque Boost (Pr. 0, Pr. 46)
75
Large Starting Torque and Low Speed Torque Are Necessary (General-Purpose Magnetic Flux Vector Control (Pr. 71, Pr. 80))
77
Test Run
78
Slip Compensation (Pr. 245 to Pr. 247)
80
Stall Prevention Operation (Pr. 22, Pr. 23, Pr. 48, Pr. 66, Pr. 156, Pr. 157)
81
Limit the Output Frequency
85
Maximum/Minimum Frequency (Pr. 1, Pr. 2, Pr. 18)
85
Avoid Mechanical Resonance Points (Frequency Jumps) (Pr. 31 to Pr. 36)
86
Set V/F Pattern
87
Base Frequency, Voltage (Pr. 3, Pr. 19, Pr. 47)
87
Load Pattern Selection (Pr. 14)
89
Frequency Setting by External Terminals
91
Operation by Multi-Speed Operation (Pr. 4 to Pr. 6, Pr. 24 to Pr. 27, Pr. 232 to Pr. 239)
91
Jog Operation (Pr. 15, Pr. 16)
93
Remote Setting Function (Pr. 59)
95
Setting of Acceleration/Deceleration Time and Acceleration/ Deceleration Pattern
98
Setting of the Acceleration and Deceleration Time (Pr. 7, Pr. 8, Pr. 20, Pr. 44, Pr. 45)
98
Starting Frequency and Start-Time Hold Function (Pr. 13, Pr. 571)
100
Acceleration/Deceleration Pattern (Pr. 29)
101
Selection and Protection of a Motor
102
Motor Overheat Protection (Electronic Thermal O/L Relay, PTC Thermistor Protection) (Pr. 9, Pr. 51, Pr. 561)
102
Applied Motor (Pr. 71, Pr. 450)
105
To Exhibit the Best Performance of the Motor (Offline Auto Tuning) (Pr. 71, Pr. 80, Pr. 82 to Pr. 84, Pr. 90, Pr. 96)
107
Motor Brake and Stop Operation
111
DC Injection Brake (Pr. 10 to Pr. 12)
111
Selection of a Regenerative Brake (Pr. 30, Pr. 70)
112
Stop Selection (Pr. 250)
114
Function Assignment of External Terminal and Control
115
Input Terminal Function Selection (Pr. 178 to Pr. 182)
115
Inverter Output Shutoff Signal (MRS Signal, Pr. 17)
117
Condition Selection of Function Validity by Second Function Selection Signal (RT)
118
Start Signal Operation Selection (STF, STR, STOP Signal, Pr. 250)
119
Output Terminal Function Selection (Pr. 190, Pr. 192)
121
Detection of Output Frequency (SU, FU Signal, Pr. 41 to Pr. 43)
125
Output Current Detection Function (Y12 Signal, Y13 Signal, Pr. 150 to Pr. 153, Pr. 166, Pr. 167)
126
Remote Output Selection (REM Signal, Pr. 495, Pr. 496)
128
Monitor Display and Monitor Output Signal
129
Speed Display and Speed Setting (Pr. 37)
129
Monitor Display Selection of Operation Panel/Pu and Terminal am (Pr. 52, Pr.158, Pr. 170, Pr. 171, Pr. 268, Pr. 563, Pr. 564, Pr. 891)
130
Reference of the Terminal am (Analog Voltage Output) (Pr. 55, Pr. 56)
135
Terminal am Calibration (Calibration Parameter C1 (Pr.901))
136
Operation Selection at Power Failure and Instantaneous Power Failure
138
Automatic Restart after Instantaneous Power Failure/Flying Start (Pr. 30, Pr. 57, Pr. 58, Pr. 96, Pr. 162, Pr. 165, Pr. 298, Pr. 299, Pr. 611)
138
Power-Failure Deceleration Stop Function (Pr. 261)
144
Operation Setting at Fault Occurrence
146
Retry Function (Pr. 65, Pr. 67 to Pr. 69)
146
Input/Output Phase Loss Protection Selection (Pr. 251, Pr. 872)
148
Earth (Ground) Fault Detection at Start (Pr. 249)
148
Energy Saving Operation
149
Optimum Excitation Control (Pr. 60)
149
Motor Noise, EMI Measures, Mechanical Resonance
150
PWM Carrier Frequency and Soft-PWM Control (Pr. 72, Pr. 240, Pr. 260)
150
Speed Smoothing Control (Pr. 653)
151
Frequency Setting by Analog Input (Terminal 2, 4)
152
Analog Input Selection (Pr. 73, Pr. 267)
152
Response Level of Analog Input and Noise Elimination (Pr. 74)
154
Bias and Gain of Frequency Setting Voltage (Current) (Pr. 125, Pr. 126, Pr. 241, C2 (Pr. 902) to C7 (Pr. 905))
155
Misoperation Prevention and Parameter Setting Restriction
160
Reset Selection/Disconnected PU Detection/Pu Stop Selection (Pr. 75)
160
Parameter Write Disable Selection (Pr. 77)
163
Reverse Rotation Prevention Selection (Pr. 78)
164
Extended Parameter Display (Pr. 160)
164
Password Function (Pr. 296, Pr. 297)
165
Selection of Operation Mode and Operation Location
167
Operation Mode Selection (Pr. 79)
167
Operation Mode at Power-On (Pr. 79, Pr. 340)
177
Start Command Source and Frequency Command Source During Communication Operation (Pr. 338, Pr. 339, Pr. 551)
178
Communication Operation and Setting
182
Wiring and Configuration of PU Connector
182
Initial Settings and Specifications of RS-485 Communication (Pr. 117 to Pr. 120, Pr. 123, Pr. 124, Pr. 549)
185
Operation Selection at Communication Error Occurrence (Pr. 121, Pr. 122, Pr. 502)
186
Communication EEPROM Write Selection (Pr. 342)
189
Mitsubishi Inverter Protocol (Computer Link Communication)
190
Run Command
200
Modbus RTU Communication Specifications (Pr. 117, Pr. 118, Pr. 120, Pr. 122, Pr. 343, Pr. 502, Pr. 549)
202
Special Operation and Frequency Control
214
PID Control (Pr. 127 to Pr. 134, Pr. 575 to Pr. 577)
214
Dancer Control (Pr. 44, Pr. 45, Pr. 128 to Pr. 134)
222
Regeneration Avoidance Function (Pr. 665, Pr. 882, Pr. 883, Pr. 885, Pr. 886)
228
Useful Functions
230
Cooling Fan Operation Selection (Pr. 244)
230
Display of the Life of the Inverter Parts (Pr. 255 to Pr. 259)
231
Maintenance Timer Alarm (Pr. 503, Pr. 504)
235
Current Average Value Monitor Signal (Pr. 555 to Pr. 557)
236
Free Parameter (Pr. 888, Pr. 889)
238
Setting the Parameter Unit and Operation Panel
239
RUN Key Rotation Direction Selection (Pr. 40)
239
PU Display Language Selection(Pr.145)
239
Operation Panel Frequency Setting/Key Lock Operation Selection (Pr. 161)
240
Magnitude of Frequency Change Setting (Pr. 295)
242
Buzzer Control (Pr. 990)
243
PU Contrast Adjustment (Pr. 991)
243
Parameter Clear/ All Parameter Clear
244
Initial Value Change List
245
Check and Clear of the Faults History
246
5 Troubleshooting
249
Reset Method of Protective Function
250
List of Fault or Alarm Indications
251
Causes and Corrective Actions
252
Correspondences between Digital and Actual Characters
261
Check First When You Have some Troubles
262
Motor Does Not Start
262
Motor or Machine Is Making Abnormal Acoustic Noise
264
Inverter Generates Abnormal Noise
265
Motor Generates Heat Abnormally
265
Motor Rotates in the Opposite Direction
265
Speed Greatly Differs from the Setting
265
Acceleration/Deceleration Is Not Smooth
266
Speed Varies During Operation
266
Operation Mode Is Not Changed Properly
267
Operation Panel Display Is Not Operating
267
Motor Current Is too Large
267
Speed Does Not Accelerate
268
Unable to Write Parameter Setting
268
6 Precautions for Maintenance and Inspection
270
Inspection Items
270
Daily Inspection
270
Periodic Inspection
270
Daily and Periodic Inspection
271
Display of the Life of the Inverter Parts
272
Checking the Inverter and Converter Modules
273
Cleaning
274
Replacement of Parts
274
Measurement of Main Circuit Voltages, Currents and Powers
278
Measurement of Powers
280
Measurement of Voltages and Use of PT
280
Measurement of Currents
281
Use of CT and Transducer
281
Measurement of Inverter Input Power Factor
281
Measurement of Converter Output Voltage (Across Terminals P and N)
281
Insulation Resistance Test Using Megger
282
Pressure Test
282
7 Specifications
283
Rating
284
Common Specifications
286
Outline Dimension Drawings
287
Appendix
291
Appendix1 Index
292
Advertisement
Mitsubishi Electric FR-D720S-100 Installation Manuallines (30 pages)
Brand:
Mitsubishi Electric
| Category:
Inverter
| Size: 2.61 MB
Table of Contents
Table of Contents
1
Product Checking and Parts Identification
4
Outline Dimension Drawings
6
Terminal Connection Diagram
7
Main Circuit
7
Control Circuit
7
Wiring
7
Main Circuit Terminal Specifications
8
Cables and Wiring Length
10
Control Circuit Specifications
13
Precautions for Use of the Inverter
15
Failsafe of the System Which Uses the Inverter
17
Parameter List
18
Troubleshooting
22
List of Fault or Alarm Indications
23
Appendix 2 Instructions for Ul and Cul
27
Motor Overload Protection
27
Advertisement
Related Products
Mitsubishi Electric FR-D720S-1.5K
Mitsubishi Electric FR-D720S-100-EC
Mitsubishi Electric FR-D720S-100SC-EC
Mitsubishi Electric FR-D720S-0.1K
Mitsubishi Electric FR-D720S-008SC
Mitsubishi Electric FR-D720S-0.4K
Mitsubishi Electric FR-D720S-025-EC
Mitsubishi Electric FR-D720S-042-EC
Mitsubishi Electric FR-D720S-042
Mitsubishi Electric FR-D720S-070
Mitsubishi Electric Categories
Air Conditioner
Controller
Projector
Inverter
Heat Pump
More Mitsubishi Electric Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL