Sign In
Upload
Manuals
Brands
GE Interlogix Manuals
Security System
60-792-01-95R
GE Interlogix 60-792-01-95R Manuals
Manuals and User Guides for GE Interlogix 60-792-01-95R. We have
3
GE Interlogix 60-792-01-95R manuals available for free PDF download: Installation Instructions Manual, User Instructions
GE Interlogix 60-792-01-95R User Instructions (68 pages)
Concord
Brand:
GE Interlogix
| Category:
Security System
| Size: 0.92 MB
Table of Contents
Commands at a Glance
3
Table of Contents
4
Getting to Know Your Security System
9
Overview
9
Panel
9
Touchpads
9
Door/Window Sensors
9
Motion Sensors
9
Environmental Sensors
10
Phone Interface and Voice Module
10
Energy Saving Module
10
Superbus 2000 Cellular Backup Module
10
Superbus 2000 Wireless Gateway Module
10
Communicating with the Panel
10
Instructing the Panel
10
Touchpads-Your System Interface
11
Alphanumeric Touchpads
11
Fixed Display Touchpads
11
Wireless Handheld Touchpad
11
Keychain Touchpads
11
Touchtone Phones
11
Panic Buttons
11
Beeps and Leds- How Your System Talks to You
11
Key Beeps
11
Status Beeps
11
Leds
12
Notification by Pager
12
What Happens in an Alarm Condition
12
Fire and Smoke Alarms
12
Resetting Smoke Detectors
13
Preventing Accidental Alarms
13
Cancelling Accidental Alarms
13
Guidelines for Preventing Accidental Alarms
13
Basic System Operations
14
Arming Your System
14
Keychain Touchpad Arming
14
Arming Level 1-OFF
14
Arming Level 2-STAY
15
Arming Level 3-AWAY
15
Quick Arm
15
Quick Exit
15
Using the Chime Feature
16
Chime-On-Close
16
Using the Voice Chime Feature
16
Exit and Entry Delay Times
16
Exit Delay Example
16
Entry Delay Example
17
Extended Delay
17
Exit Extension
17
No Delay-For Instant Alarm
17
Auto STAY Arming Feature
18
Arming While a Door or Window Is Open
18
Bypassing a Sensor Directly
18
Bypassing a Sensor Indirectly
18
Was the Bypass Successful
19
Basic Light Control
19
Basic Output Control
19
Checking the Status of Your System
19
Short System Status
20
Full System Status
20
Panic Alarms
20
Fire Panic Alarm
20
Lighting During a Fire Panic Alarm
20
Police Panic Alarm
21
Lighting During a Police Panic Alarm
21
Auxiliary Panic Alarm
21
Lighting During an Auxiliary Panic Alarm
21
Siren Time-Out
21
Access Codes
21
Programming Access Codes
21
Access Code Integrity
22
System Master Code Privileges
22
Partition Master Code Privileges
22
Regular User Code Privileges
22
The Touchpad Tamper Feature
22
Changing or Erasing User Codes
22
Changing a User Code
22
Erasing a User Code
22
Assigning Code Attributes
23
Assigning the Direct Bypassing Attribute
23
Assigning the Remote Access Attribute
23
Assigning the Partition Jump Attribute
23
Assigning the System Test Attribute
23
Assigning the Latchkey Report Attribute
24
Setting the Time and Date
24
Adjusting System Sounds and Touchpad Brightness
24
Arming Your System Silently
24
Silent Arming on Demand
25
Arming Always Silent
25
Adjusting the Touchpad Beeps (Fixed Display Touchpad Only)
25
Adjusting the System Status Voice Volume
25
Adjusting the Touchpad Display Brightness
25
Adjusting the Volume of the Wireless Siren
26
Using the Energy Saver Feature
26
Energy Saver Example
26
Setting the Energy Saver High and Low Temperature Settings
26
Notification by Pager
27
Pager Messages
27
Event Code in Page
28
Sensor Number or User Number in Page
28
Account Number in Page
28
Streamlining the Page Report
29
Creating Time Schedules
29
Scheduling Consecutive Days
29
One Day Rollover
29
Multiple Day Rollover
30
Attaching Time Schedules
30
Time Schedules and Partitions
31
Advanced Light Control
31
Controlling Lights by Time Schedule
31
Controlling Lights with Sensors
31
Installer Programmable Lighting
32
Controlling Outputs by Time Schedule
32
Scheduled Arming
32
Opening and Closing Reports
33
When will this Feature be Active
33
Who will be Paged
33
What will the Pager Report
33
Latchkey Paging
33
Page in the Event of
33
Who Can Send a Page
33
Latchkey Opening
33
Basic Latchkey Opening
34
Advanced Latchkey Opening
34
Latchkey Closing
34
Assigning a Time Schedule to Latchkey Paging
34
Applying the Latchkey Modifier
35
Notify by Exception
35
Page in the Event of
35
Who will be Paged
35
Who Can Send a Page
35
What will the Pager Report
35
When will this Feature be Active
36
Assigning a Time Schedule to Exception Opening and Closing
36
The no Activity Feature
36
Using the Panel Download Feature
36
Using a Partitioned System
37
Global Settings
37
Partition-Specific Settings
37
Jumping Partitions
37
Arming and Disarming the Other Partition
37
Programming the Other Partition
38
System Information
38
Viewing Event Buffer
38
Overview
38
Using a Touchtone Phone to Operate Your System
41
Phone Command Prefix
41
Accessing the System from Off-Site
41
How the Panel Answers the Phone
42
Codes with Remote Access Capability
42
Touchtone Phone System Operation
42
Sending a Police Panic Alarm
43
Phone Questions
43
Testing the System
44
Automatic Test Features
44
Manual Tests
44
Sensor Test
44
Phone Communication Test
45
Troubleshooting
45
Trouble Beeps and Trouble Messages
45
Silencing Trouble Beeps
46
Common Questions and Answers
46
Phone Issues
46
Siren Issues
46
Lighting Issues
47
Appendix A: User Sheets
48
System Sensors
48
User Codes
49
Touchpad Information
50
Alphanumeric and Fixed Display Touchpads
50
Keychain Touchpads
50
Keychain Touchpad 3
51
Keychain Touchpad 4
51
Accidental Smoke and Fire Alarms
52
Dialer Abort
52
Doors and Delay Time Settings
52
System Features
53
If the Power Goes out
53
No Activity Time
53
Resetting the Smoke Detector
54
System Information
54
Paging
54
Lights
54
Outputs
55
Energy Saver
55
Alarm Sounds and Status Beeps
56
Appendix B: Planning for Emergencies
56
Floor Plan Example
56
Your Floor Plan
57
Alarm System Limitations
59
If Your System Needs Service
59
Appendix C: Programming Your System
60
Two Methods to Program Your System
60
Using Programming Menus
60
Examples of Programming Using Menus
60
Using Programming Shortcuts
62
Advertisement
GE Interlogix 60-792-01-95R Installation Instructions Manual (106 pages)
Concord Security System;
Brand:
GE Interlogix
| Category:
Security System
| Size: 1.52 MB
Table of Contents
Installation Instructions
1
Software Version
1
Table of Contents
3
About this Manual
6
Special Installation Requirements
6
UL Listed Installations
6
SIA System Requirements
7
Central Station Reporting
9
UL Canada Listed Installations
9
California State Fire Marshall Listed Installations
9
Planning the Installation
9
Standard Panel
9
Superbus 2000 Touchpads
10
Superbus 2000 RF Receivers
10
Power Line Carrier Card
10
Phone Supervision Card
10
Supervised Wireless Siren
10
Superbus 2000 Phone Interface/Voice Module
10
Snapcards
10
Superbus 2000 8Z Input Module (HIM)
11
Superbus 2000 4-Relay Output Module (HOM)
11
Interrogator 200 Audio Verification Module
11
Superbus 2000 Cellular Backup Module
11
Superbus 2000 Energy Saver Module (ESM)
11
Superbus 2000 Automation Module
11
Superbus 2000 Wireless Gateway Module
11
Installing the System
11
Determine the Panel Location
12
Total System Power and Wire Length Guidelines
12
Mounting the Panel
14
Identify Panel Components
15
Installing Antennas
15
Connecting the Panel to Earth Ground
16
Installing the Optional Power Line Carrier Card (60-755)
16
Installing the Optional Phone Supervision Card (60-789)
16
Installing Optional Snapcards
17
Connecting Detection Devices to Panel Zone Inputs
17
Connecting Intrusion Detection Devices
17
Connecting 2-Wire Smoke Detectors
17
Connecting 4-Wire Smoke Detectors
18
Connecting Speakers
19
15-Watt Speaker (13-060)
19
Hardwire Interior Speaker (60-528)
19
Connecting Piezo Sirens
20
Exterior Sirens
20
Interior Sirens
20
Installing Supervised Wireless Sirens (60-736-95)
21
Connecting an Interrogator 200 Audio Verification Module (60-677)
22
Connecting Alphanumeric and Fixed Display Touchpads
22
Installing Superbus 2000 Modules
23
Superbus 2000 RF Receiver (60-764-01-95R-16Z/32Z/MAX)
23
Superbus 2000 Phone Interface/Voice Module (60-777-01)
24
Superbus 2000 Energy Saver Module (60-620-01)
25
Superbus 2000 8Z Input Module (60-774)
25
Superbus 2000 4-Relay Output Module (60-770)
25
Superbus 2000 Cellular Backup Module
26
Superbus 2000 Automation Module (60-783-02)
26
Superbus 2000 Wireless Gateway Module (60-861)
26
Setting Device Address on Superbus 2000 Devices
27
Installing an RJ-31X Phone Jack (13-081)
27
Connecting the Phone Line to the Panel with a DB-8 Cord
27
Connecting the AC Power Transformer
28
Powering up the Panel
28
Programming the Panel
29
Entering Program Mode
29
Touchpad Button Programming Functions
29
Moving through Program Mode Tiers and Menus
30
Programming Tier 1 Menu Items
31
Programming Tier 2 Menu Items
32
Using Shortcut Numbers
32
Security Menu
32
Phones Menu
35
Phone Options Menu
40
Timers Menu
44
Light Control Menu
46
Touchpad Options Menu
47
Reporting Menu
48
Siren Options Menu
53
Sensors Menu
54
Audio Verification Menu
56
Accessory Modules Menu
58
Output Programming
59
Status Beeps
59
Key Beeps
60
Onboard Options Menu
61
Exiting Programming Mode
63
Entering User Programming Mode
63
Time and Date Menu
63
User Codes Menu
64
Options Menu
66
Set up Schedules Menu
67
Attach Schedules to Events Menu
68
Attach Lights to Sensors Menu
70
System Version Menu
70
Downloader Programming
71
Toolbox Downloader Programming
71
Testing the System
71
Basic System Commands
71
Testing Zones/Sensors
72
If a Wireless Sensor Does Not Test
72
Testing Phone Communication
72
Testing Central Station/Pager Communication
73
Testing Outputs and Sirens
73
Testing Light Control
74
Testing the Energy Saver Module (ESM)
74
Changing Fixed Display LCD Touchpad Chime and Trouble Beep Tones
74
Adjusting Touchpad Display Contrast
75
Testing Audio Verification Module (AVM) Communication
75
Testing Cellular Backup Communication
75
Troubleshooting
76
Appendix A: System Planning Worksheets
82
Appendix B: Reference Tables
89
Cross-Zoning
90
Appendix C: Settings
101
Entry Delay
102
Exit Delay
103
Event Buffer
103
Specifications
104
System Wiring Notes
105
GE Interlogix 60-792-01-95R Installation Instructions Manual (100 pages)
Concord Security System
Brand:
GE Interlogix
| Category:
Security System
| Size: 1.75 MB
Table of Contents
Installation Instructions
1
Software Version
1
Fcc Notices
2
Table of Contents
3
About this Manual
6
Special Installation Requirements
6
UL Listed Installations
6
Central Station Reporting
7
UL Canada Listed Installations
7
California State Fire Marshall Listed Installations
8
Planning the Installation
8
Standard Panel
8
Superbus 2000 Touchpads
8
Superbus 2000 RF Receivers
9
Power Line Carrier Card
9
Phone Supervision Card
9
Supervised Wireless Siren
9
Superbus 2000 Phone Interface/Voice Module
9
Snapcards
9
Superbus 2000 8Z Input Module (HIM)
9
Superbus 2000 4-Relay Output Module (HOM)
9
Interrogator 200 Audio Verification Module
9
Superbus 2000 Cellular Backup Module
9
Superbus 2000 Energy Saver Module (ESM)
10
Superbus 2000 Automation Module
10
Superbus 2000 Wireless Gateway Module
10
Installing the System
10
Determine the Panel Location
10
Total System Power and Wire Length Guidelines
11
Mounting the Panel
13
Identify Panel Components
14
Installing Antennas
14
Connecting the Panel to Earth Ground
15
Installing the Optional Power Line Carrier Card (60-755)
15
Installing the Optional Phone Supervision Card (60-789)
15
Installing Optional Snapcards
16
Connecting Detection Devices to Panel Zone Inputs
16
Connecting Intrusion Detection Devices
16
Connecting 2-Wire Smoke Detectors
16
Connecting 4-Wire Smoke Detectors
17
Connecting Speakers
17
15-Watt Speaker (13-060)
18
Hardwire Interior Speaker (60-528)
18
Connecting Piezo Sirens
19
Exterior Sirens
19
Interior Sirens
19
Installing Supervised Wireless Sirens (60-736-95)
19
Connecting an Interrogator 200 Audio Verification Module (60-677)
20
Connecting Alphanumeric and Fixed Display Touchpads
21
Installing Superbus 2000 Modules
21
Superbus 2000 RF Receiver (60-764-01-95R-16Z/32Z/MAX)
22
Superbus 2000 Phone Interface/Voice Module (60-777-01)
22
Superbus 2000 Energy Saver Module (60-620-01)
23
Superbus 2000 8Z Input Module (60-774)
24
Superbus 2000 4-Relay Output Module (60-770)
24
Superbus 2000 Cellular Backup Module
24
Superbus 2000 Automation Module
25
Superbus 2000 Wireless Gateway Module (60-861)
25
Setting Device Address on Superbus 2000 Devices
26
Installing an RJ-31X Phone Jack (13-081)
26
Connecting the Phone Line to the Panel with a DB-8 Cord
26
Connecting the AC Power Transformer
27
Powering up the Panel
27
Programming the Panel
27
Entering Program Mode
27
Touchpad Button Programming Functions
28
Moving through Program Mode Tiers and Menus
28
Programming Tier 1 Menu Items
29
Programming Tier 2 Menu Items
30
Using Shortcut Numbers
30
Security Menu
31
Phones Menu
34
Phone Options Menu
37
Timers Menu
41
Light Control Menu
43
Touchpad Options Menu
43
Reporting Menu
44
Siren Options Menu
49
Sensors Menu
50
Audio Verification Menu
52
Accessory Modules Menu
54
Onboard Options Menu
57
Exiting Programming Mode
58
Entering User Programming Mode
58
Time and Date Menu
59
User Codes Menu
59
Options Menu
61
Set up Schedules Menu
62
Attach Schedules to Events Menu
63
Attach Lights to Sensors Menu
64
System Version Menu
65
Downloader Programming
65
Toolbox Downloader Programming
65
Testing the System
65
Basic System Commands
65
Testing Zones/Sensors
66
If a Wireless Sensor Does Not Test
66
Testing Phone Communication
67
Testing Central Station/Pager Communication
67
Testing Outputs and Sirens
68
Testing Light Control
68
Testing the Energy Saver Module (ESM)
68
Changing Fixed Display LCD Touchpad Chime and Trouble Beep Tones
69
Adjusting Touchpad Display Contrast
69
Testing Audio Verification Module (AVM) Communication
69
Testing Cellular Backup Communication
69
Troubleshooting
71
Appendix A: System Planning Worksheets
77
Appendix B: Reference Tables
84
Appendix C: Settings
93
Specifications
98
System Wiring Notes
99
Advertisement
Advertisement
Related Products
GE Interlogix CareGard 60-883-95R
GE Interlogix 60-875
GE Interlogix 60-734-01
GE Interlogix 60-801-01
GE Interlogix CONCORD Express
GE Interlogix Concord Security System
GE Interlogix Security Simon 60-875
GE Interlogix Simon
GE Interlogix Categories
Security System
DVR
Card Reader
Keypad
Security Camera
More GE Interlogix Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL