SERVICE MANUAL
Read this manual carefully, especially precaution on microwave energy, and follow the procedure strictly,
careless servicing and testing may expose yourself to the microwave energy leakage.
PRECAUTIONS TO BE OBSERVED BEFORE AND DURING SERVICING TO AVOID POSSIBLE EXPOSURE TO
EXCESSIVE MICROWAVE ENERGY
(a) Do not operate or allow the oven to be operated with the door open.
(b) Make the following safety checks on all ovens to be serviced before activating the magnetron or other
microwave source, and make repairs as necessary:
(1)Interlock operation, (2) proper door closing, (3) seal and sealing surfaces (arcing, wear, and other
damage), (4) damage to or loosening of hinges and latches, (5) evidence of dropping or abuse.
(c) Before turning on microwave power for any service test or inspection within the microwave generating
compartments, check the magnetron, wave guide or transmission line, and cavity for proper alignment,
integrity, and connections.
(d) Any defective or misadjusted components in the interlock, monitor, door seal, and microwave generation
and transmission systems shall be repaired replaced, or adjusted by procedures described in this manual
before the oven is released to the owner.
Microwave Oven
Foreword
PRECAUTIONS
EM-C1800MK
EM-C1800MK
Model No
Pro.Code No
EM-C1800MKSD
437 477 00
EM-C1800MKUK
437 477 01
REFERENCE NO. SM-640177
(Germany)
(U.K)