hit counter script
Craftsman 919.168700 Owner's Manual

Craftsman 919.168700 Owner's Manual

Permanently lubricated single stage portable air compressor
Hide thumbs Also See for 919.168700:
Table of Contents

Advertisement

Available languages

Available languages

Owner's Manual
Permanently Lubricated
Single Stage
Portable

AIR COMPRESSOR

Model No.
919.168700
• Safety Guidelines
• Assembly
• Operation
• Maintenance
• Service and Adjustments
• Troubleshooting
• Repair Parts
CAUTION:
Read the Safety Guidelines
and All Instructions Carefully Before
Operating.
Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A.
Visit our Craftsman website: www.sears.com/craftsman
A09711
Rev. 1 9/8/05

Advertisement

Chapters

Table of Contents
loading

Summary of Contents for Craftsman 919.168700

  • Page 1: Air Compressor

    • Maintenance • Service and Adjustments • Troubleshooting • Repair Parts CAUTION: Read the Safety Guidelines and All Instructions Carefully Before Operating. Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. Visit our Craftsman website: www.sears.com/craftsman A09711 Rev. 1 9/8/05...
  • Page 2: Table Of Contents

    WARRANTY FULL ONE YEAR WARRANTY AIR COMPRESSOR If this CRAFTSMAN Air Compressor fails due to a defect in material or workmanship within one year from the date of purchase, Sears will at its option repair or replace it free of charge. Contact your nearest Sears Service Center (1-800-4-MY-HOME ®...
  • Page 3: Specification Chart

    SPECIFICATION CHART Model No. 919.168700 Running HP Bore 2.38" Stroke 1.35" Voltage-Single Phase 120V/60HZ/1PH Minimum Branch Circuit Requirement 15 amps Fuse Type Time Delay Air Tank Capacity Approx. Cut-In Approx. Cut-out SCFM @ 40 psig SCFM @ 90 psig Refer to Glossary for abbreviations...
  • Page 4 IMPORTANT SAFETY INSTRUCTIONS Save these instructions Improper operation or maintenance of this product could result in serious injury and property damage. Read and understand all warnings and operation instructions before using this equipment. HAZARD WARNING: Risk of explosion or fire What Could Happen How To Prevent It It is normal for electrical contacts...
  • Page 5 HAZARD WARNING: Risk of Bursting Air Tank: The following conditions could lead to a weakening of the tank, and result in a violent tank explosion and could cause property damage or serious injury. What Could Happen How To Prevent It HAZARD WARNING: Risk from Flying Objects Always wear ANSI Z87.1 approved safety...
  • Page 6 HAZARD WARNING: Risk of Electrical Shock What Could Happen How To Prevent It Your air compressor is powered by Never operate the compressor outdoors electricity. Like any other electrically when it is raining or in wet conditions. powered device, If it is not used Never operate compressor with properly it may cause electric shock.
  • Page 7 WARNING: Risk of Burns Never touch any exposed metal parts Touching exposed metal such as the on compressor during or immediately compressor head or outlet tubes, can after operation. Compressor will remain result in serious burns. hot for several minutes after operation. Do not reach around protective shrouds or attempt maintenance until unit has been allowed to cool.
  • Page 8 Unsafe operation of your air compressor Review and understand all instructions and warnings in this manual. could lead to serious injury or death to Become familiar with the operation and you or others. controls of the air compressor. Keep operating area clear of all persons, pets, and obstacles.
  • Page 9: Glossary

    GLOSSARY When the tank pressure drops to a Become familiar with these terms certain low level the motor will restart before operating the unit. automatically. The low pressure CFM: Cubic feet per minute. at which the motor automatically SCFM: Standard cubic feet per restarts is called "cut-in"...
  • Page 10: Assembly

    ASSEMBLY Unpacking Remove unit from carton and discard all packaging. INSTALLATION HOW TO SET UP YOUR UNIT Make sure the outlet being used has the same configuration as the grounded plug. DO NOT USE AN ADAPTER. See illustration. Grounding Pin Inspect the plug and cord before GROUNDING INSTRUCTIONS each use.
  • Page 11: Extension Cords

    Extension Cords Voltage and Circuit Protection Using extension cords is not Refer to the specification chart for the recommended. The use of extension voltage and minimum branch circuit cords will cause voltage to drop requirements. resulting in power loss to the motor Risk of Unsafe and overheating.
  • Page 12: Operation

    OPERATION Know Your Air Compressor READ THIS OWNER’S MANUAL AND SAFETY RULES BEFORE OPERATING YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with the location of various controls and adjustments. Save this manual for future reference. Description of Operation Tank Pressure Gauge: The tank Become familiar with these controls pressure gauge indicates the reserve...
  • Page 13: How To Use Your Unit

    Air Compressor Pump (not shown): Motor Overload Protector: The Compresses air into the air tank. motor has an automatic reset Working air is not available until the thermal overload protector. If the compressor has raised the air tank motor overheats for any reason, the pressure above that required at the overload protector will shut "Off"...
  • Page 14: How To Start

    How to Start: Move the On/Auto/Off lever to "On/Auto" position. The Turn the On/Auto/Off lever compressor will start. to "On/Auto" and allow tank Run the compressor for 15 pressure to build. Motor will minutes. Make sure the drain stop when tank pressure reaches valve is open and there is "cut-out"...
  • Page 15: Maintenance

    MAINTENANCE Customer Responsibilities Daily Before Every Every or after each Yearly each hours hours Check Safety Valve ● Drain Tank ● Air Filter ● ● Air compressor pump intake ● and exhaust valves 1- more frequent in dusty or humid conditions To Check Safety Valve Risk of Unsafe Operation.
  • Page 16 After the water has been drained, IMPORTANT: Do not operate close the drain valve (clockwise). the compressor with the air filter The air compressor can now be removed. stored. If dirty, rinse air filter with warm NOTE: If drain valve is plugged, water and squeeze dry.
  • Page 17: Service And Adjustments

    SERVICE AND ADJUSTMENTS Unscrew the check valve (turn counterclockwise) using a 7/8" open end wrench. Note the orientation for reassembly. Using a screwdriver, carefully push the valve disc up and down. NOTE: The valve disc should move freely up and down on a spring which holds the valve disc in the closed position;...
  • Page 18: To Replace Regulator

    Assemble the regulator and To Replace Regulator orient as shown. Release all air pressure from air tank. See "To Drain Tank" in the "Maintenance" section. Set the On/Auto/Off lever to "Off" and unplug unit. Remove the outlet pressure gauge and quick connect (if equipped) from the regulator.
  • Page 19: Storage

    STORAGE Risk of Bursting. Before you store the air compressor, Water will make sure you do the following: condense in the air tank. If not Review the "Maintenance" drained, water will corrode and section on the preceding weaken the air tank causing a risk pages and perform scheduled of air tank rupture.
  • Page 20 TROUBLESHOOTING Risk of Unsafe Operation. Unit cycles automatically when power is on. When servicing, you may be exposed to voltage sources, compressed air, or moving parts. Before servicing unit unplug or disconnect electrical supply to the air compressor, bleed tank of pressure, and allow the air compressor to cool.
  • Page 21 PROBLEM CAUSE CORRECTION Pressure reading It is normal for "some" If there is an excessive on the regulated pressure drop to occur. amount of pressure drop pressure gauge when the accessory is used, drops when an adjust the regulator following accessory is the instructions in the used.
  • Page 22 PROBLEM CAUSE CORRECTION Regulator will Damaged regulator. Replace. not shut "Off" air outlet. Motor will not Motor overload protection Let motor cool "Off" run. and overload switch will switch has tripped. automatically reset. Tank pressure exceeds Motor will start automatically when tank pressure drops pressure switch "cut-in"...
  • Page 23 NOTES 23- ENG A09711 A09711...
  • Page 24 GARANTÍA GARANTÍA TOTAL DE UN AÑO DEL COMPRESOR DE AIRE Si este compresor de aire Craftsman fallase debido a defectos de materiales o de fabricación dentro del año de su fecha de compra, Sears, a su opción, lo reparará o reemplazará sin costo alguno. Comuníquese con el Centro de Servicio Sears más cercano (1-800-4-MY-HOME) para coordinar su...
  • Page 25: Cuadro De Especificaciones

    CUADRO DE ESPECIFICACIONES Modelo Nº 919.168700 HP de Trabajo Diámetro interior 2,38 pulg. (60,4 mm) Carrera 1,35 pulg. (34,3 mm) Tensión monofásica 120V/60HZ/1PH Circuito mínimo requerido Tipo de fusible Acción retardada Capacidad de aire en el tanque 33 Galones (124,9 litros) Presión de corte de entrada...
  • Page 26 INSTRUCCIONES IMPORTANTES DE SEGURIDAD GUARDE ESTAS INSTRUCCIONES La operación o el mantenimiento inadecuados de este producto podrían ocasionar serias lesiones y daños a la propiedad. Lea y comprenda todas las advertencias e instrucciones de funcionamiento antes de utilizar este equipo. ADVERTENCIA: Riesgo de Explosión o Incendio 30- SP A09711...
  • Page 27 PELIGRO ADVERTENCIA: Riesgo de Explosión Tanque de aire: las siguientes condiciones podrían, causar el debilitamiento del tanque, y determinar su explosión violenta, daños a la propiedad o serias lesiones. qué puede occurrir cómo prevenirlo Drenaje inadecuado del agua condensada Drene el tanque diariamente o después de en el tanque, siendo la causa del óxido que cada uso.
  • Page 28 PELIGRO ADVERTENCIA: Riesgo de Descarga Eléctrica cómo prevenirlo qué puede occurrir Su compresor de aire está accionado por Jamás opere el compresor a la intemperie electricidad. Como cualquier otro dispositivo cuando está lloviendo o en condiciones de eléctrico impulsado eléctricamente, si no se lo humedad.Nunca opere el compresor sin sus utiliza adecuadamente, podría causarle una defensas o sus cubiertas removidas o...
  • Page 29 PELIGRO ADVERTENCIA: Riesgo de Quemaduras Jamás toque partes de metal expuestas en el Tocar el metal expuesto tal como el cabezal compresor durante o inmediatamente después del compresor o los tubos de salida del escape, de la operación. el compresor permanecerá puede ocasionarle serias quemaduras.
  • Page 30 34- SP A09711...
  • Page 31: Glosario

    GLOSARIO Presión mínima de corte: Cuando el Familiarícese con los siguientes términos, motor está apagado, la presión del tanque antes de operar la unidad: de aire baja a medida que usted continúa CFM: (Cubic feet per minute) Pies cúbicos usando su accesorio. Cuando la presión por minuto.
  • Page 32: Ensamblado

    ENSAMBLADO Desempaque Extraiga la unidad de su caja y descarte todas las partes de embalaje. INSTALACIÓN CÓMO PREPARAR LA UNIDAD Asegúrese de que el tomacorriente que será utilizado tenga la misma configuración que el enchufe de conexión a tierra. NO UTILICE UN ADAPTADOR.
  • Page 33 Cables de extensión eléctrica Protección del voltaje y del circuito No se recomienda la utilización de cables Acerca del voltaje y la mínima cantidad de circuitos requeridos, refiérase al cuadro de de extensión eléctrica. El uso de cables especificaciones. de extensión eléctrica originará una caída de tensión, lo que determinará...
  • Page 34: Operación

    OPERACIÓN Conozca su compresor de aire LEA ESTE MANUAL DEL PROPIETARIO Y SUS NORMAS DE SEGURIDAD ANTES DE OPERAR LA UNIDAD. Compare las ilustraciones contra su unidad a fin de familiarizarse con la ubicación de los distintos controles y regulaciones. Conserve este manual para referencias futuras.
  • Page 35 Bomba de compresión del aire (no Si el protector de sobrecarga apaga el mostrada): Comprime el aire dentro del motor con mucha frecuencia, verifique si tanque. El aire de trabajo no se encuentra hay algún posible problema de voltaje. disponible hasta que el compresor haya También se puede sospechar de alcanzado a llenar el tanque hasta un nivel bajo voltaje cuando:...
  • Page 36 Cómo poner en marcha: Antes de cada puesta en marcha: Mueva la palanca On/Auto/Off a la Coloque el interruptor On/Auto/Off en posición "On/Auto" y deje que se la posición "Off" y cierre el regulador de incremente la presión del tanque. El aire.
  • Page 37: Mantenimiento

    MANTENIMIENTO Responsabilidades del cliente Antes Diariamente Cada Cada Anualmente o luego de de cada cada uso horas horas Verifique la válvula de seguridad ● Drenaje del tanque ● Filtro de aire ● ● Válvulas de entrada y escape de ● la bomba del compresor de aire 1- Más frecuente en condiciones polvorientas o húmedas.
  • Page 38 Extraiga el retén del filtro de aire. Riesgo de Explosión. Dentro del tanque Retire el filtro de aire y asegúrese de se producirá condensación de agua. que esté limpio. Si no drena, el agua lo corroerá y IMPORTANTE: No opere el compresor debilitará...
  • Page 39 SERVICIO Y AJUSTES Desenrosque la válvula de retención girándola hacia la izquierda usando una llave de boca de 7/8 plug. (22 mm). Tome nota de la orientación para volverla a ensamblar. Usando un destornillador, empuje con cuidado el disco de la válvula hacia arriba y hacia abajo.
  • Page 40 Ensamble el regulador y oriéntelo de Para reemplazar el regulador acuerdo a lo mostrado. Libere toda la presión del aire del tanque. Vea "Drenaje del tanque" en la sección "Mantenimiento". Apagar la unidad colocando el interruptor en On/Auto/Off en "Off". Usando una llave de tuercas ajustable retire el medidor de salida de presión y la conexióN rápida del regulador (si...
  • Page 41: Almacenaje

    ALMACENAJE Antes de guardar su compresor de aire, Riesgo de asegúrese de hacer lo siguiente: Explosión. El Revise la sección "Mantenimiento" agua se condensa dentro del tanque de las páginas precedentes y ejecute de aire. Si no se drena, ella corroerá el mantenimiento programado de debilitando la paredes del tanque de acuerdo a la necesidad.
  • Page 42: Guía De Diagnóstico De Problemas

    GUÍA DE DIAGNÓSTICO DE PROBLEMAS Riesgo de Operación Insegura: La unidad arranca automáticamente cuando está enchufada. Al hacer el mantenimiento, el operador puede quedar expuesto a fuentes de corriente y de aire comprimido o a piezas movibles. Antes de intentar hacer reparaciones, desconectar el compresor del tomacorriente, drenar la presión de aire del tanque y esperar a que el compresor se enfríe.
  • Page 43 CORRECCIÓN PROBLEMA CAUSA Si hubiese una caída excesiva Es normal que ocurra algún La lectura de la de presión durante el uso del descenso en la presión. presión sobre un accesorio, ajuste el regulador de manómetro (si acuerdo a las instrucciones de la viene equipado sección "Operación".
  • Page 44 PROBLEMA CAUSA CORRECCIÓN Deje enfriar el motor y el El motor no El interruptor de protección des funciona. interruptor de sobrecarga se obrecarga del motor se ha reajustará automáticamente. abierto. El motor arrancará automáticamente La presión del tanque excede cuando la presión del tanque caiga la presión de "corte máximo"...
  • Page 45 NOTES/NOTAS 49- SP A09711...
  • Page 46: Notes/Notas

    NOTES/NOTAS 50- SP A09711...
  • Page 47: Contratos De Protección Para Reparaciones

    Congratulations on making a smart purchase. Your new Craftsman ® product Felicitaciones por hacer una compra inteligente. Su nueva unidad Craftsman ® está is designed and manufactured for years diseñada y fabricada para años de operación of dependable operation. But like all confiable;...
  • Page 48 Get it fixed, at your home or ours! Your Home For repair – in your home – of all major brand appliances, lawn and garden equipment, or heating and cooling systems, no matter who made it, no matter who sold it! For the replacement parts, accessories and owner’s manuals that you need to do-it-yourself.

Table of Contents