hit counter script
Mitsubishi Electric City Multi PMFY-P-VBM-E Installation Manual
Mitsubishi Electric City Multi PMFY-P-VBM-E Installation Manual

Mitsubishi Electric City Multi PMFY-P-VBM-E Installation Manual

Air-conditioners for building application indoor unit
Hide thumbs Also See for City Multi PMFY-P-VBM-E:

Advertisement

Quick Links

Air-Conditioners For Building Application
INDOOR UNIT
PMFY - P

INSTALLATION MANUAL

For safe and correct use, read this manual and the outdoor unit installation manual thoroughly before installing
the air-conditioner unit.
INSTALLATIONSHANDBUCH
Aus Sicherheitsgründen und zur richtigen Anwendung vor Installation der Klimaanlage die vorliegende Bedie-
nungsanleitung und das Installationshandbuch gründlich durchlesen.
MANUEL D'INSTALLATION
Avant d'installer le climatiseur, lire attentivement ce manuel, ainsi que le manuel d'installation de l'appareil exté-
rieur pour une utilisation sûre et correct.
INSTALLATIEHANDLEIDING
Lees deze handleiding en de installatiehandleiding van het buitenapparaat zorgvuldig door voordat u met het
installeren van de airconditioner begint.
MANUAL DE INSTALACIÓN
Para un uso seguro y correcto, lea detalladamente este manual de instalación antes de montar la unidad de
aire acondicionado.
MANUALE DI INSTALLAZIONE
Per un uso sicuro e corretto, prima di installare il condizionatore d'aria leggere attentamente il presente manuale
ed il manuale d'installazione dell'unità esterna.
ΕΓΧΕΙΡΙΔΙΟ ΟΔΗΓΙΩΝ ΕΓΚΑΤΑΣΤΑΣΗΣ
Για σωστή και ασφαλή χρήση, διαβάστε προσεκτικά αυτό το εγχειρίδιο, καθώς και το εγχειρίδιο εγκατάστασης
της εξωτερικής μονάδας, πριν από την εγκατάσταση της μονάδας κλιματιστικού.
MANUAL DE INSTALAÇÃO
Para uma utilização segura e correcta, leia atentamente este manual e o manual de instalação da unidade exte-
rior antes de instalar o aparelho de ar condicionado.
MONTAJ ELKİTABI
Emniyetli ve doğru kullanım için, klima cihazını monte etmeden önce bu kılavuzu ve dış ünite montaj kılavuzunu
tamamıyla okuyun.
РУКОВОДСТВО ПО УСТАНОВКЕ
Для обеспечения безопасной и надлежащей эксплуатации внимательно прочтите данное руководство и
руководство по установке наружного прибора перед установкой кондиционера.
VBM-E
FOR INSTALLER
FÜR INSTALLATEURE
POUR L'INSTALLATEUR
VOOR DE INSTALLATEUR
PARA EL INSTALADOR
PER L'INSTALLATORE
ΓΙΑ ΑΥΤΟΝ ΠΟΥ ΚΑΝΕΙ ΤΗΝ ΕΓΚΑΤΑΣΤΑΣΗ
PARA O INSTALADOR
MONTÖR İÇİN
ДЛЯ УСТАНОВИТЕЛЯ
English (GB)
Deutsch (D)
Français (F)
Nederlands (NL)
Español (E)
Italiano (I)
Ελληνικά (GR)
Português (P)
Türkçe (TR)
Русский (RU)

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric City Multi PMFY-P-VBM-E

  • Page 1: Installation Manual

    Air-Conditioners For Building Application INDOOR UNIT PMFY - P VBM-E • INSTALLATION MANUAL FOR INSTALLER English (GB) For safe and correct use, read this manual and the outdoor unit installation manual thoroughly before installing the air-conditioner unit. INSTALLATIONSHANDBUCH FÜR INSTALLATEURE Deutsch (D) Aus Sicherheitsgründen und zur richtigen Anwendung vor Installation der Klimaanlage die vorliegende Bedie- nungsanleitung und das Installationshandbuch gründlich durchlesen.
  • Page 2: Table Of Contents

    Contents 4. Electrical work ....................6 1. Safety precautions ..................2 2. Installing the indoor unit................2 5. Installing the grille ..................7 6. Test run ......................9 3. Refrigerant pipe and drain pipe ..............4 Note: The phrase “Wired remote controller” in this installation manual refers only to the PAR-21MAA. If you need any information for the other remote controller, please refer to either the installation manual or initial setting manual which are included in these boxes. 1. Safety precautions ► Before installing the unit, make sure you read all the “Safety precau- : Indicates an action that must be avoided.
  • Page 3: Installation Location

    . Installation location (mm) 2.2. Service space (Fig. 2-2) • The dimensions of ceiling opening can be regulated within the range shown in following diagram; so centre the main unit against the opening of ceiling, ensur- ing that the respective opposite sides on all sides of the clearance between them becomes identical.
  • Page 4: Installing The Indoor Unit

    . Installing the indoor unit 1. 2. 3. (mm) Check the pitch of the suspension bolt. (340 mm × 811 mm) 1. Thread washers 1 2 (supplied) and their nuts (procured locally) onto the sus- pension bolt in advance. (Fig. 2-7) * Do this in the following order (from the top): nut, insulated washer 2, washer without insulation 1, 2 nuts.
  • Page 5 3. Refrigerant pipe and drain pipe .. Connecting pipes (Fig. -) 45°±2° • When commercially available copper pipes are used, wrap liquid and gas pipes with commercially available insulation materials (heat-resistant to 100 °C or more, thickness of 12 mm or more). • The indoor parts of the drain pipe should be wrapped with polyethylene foam in- sulation materials (specific gravity of 0.03, thickness of 9 mm or more).
  • Page 6: Electrical Work

    3. Refrigerant pipe and drain pipe 1. Connect the drain socket (supplied with the unit) to the drain port. (Fig. 3-5) (mm) (Fix the tube using PVC adhesive then secure it with a band.) 2. Install a locally purchased drain pipe (PVC pipe, O.D. ø26). (Fix the pipe using PVC adhesive then secure it with a band.) 3.
  • Page 7: Installing The Grille

    4. Electrical work 4.3. Types of control cables 1. Wiring transmission cables M1 M2 M1 M2 M1 M2 Types of transmission cable Shielding wire CVVS or CPEVS TB15 TB5 TB15 Cable diameter More than 1.25 mm² Length Less than 200 m 2. M-NET Remote control cables Types of remote control cable Shielding wire MVVS Cable diameter 0.5 to 1.25 mm²...
  • Page 8 . Installing the grille A Points for securing the grille E Drainage pan B Points for securing the grille F Places for securing front grille G Make sure these surfaces are flush with C Indoor unit each other (0 - 3 mm). D Ceiling surface 5.2. Checks before setting in place (Fig. 5-2, 3) •...
  • Page 9: Test Run

    . Installing the grille 5.4. Checks after installing (Fig. 5-6) • Check that there are no gaps between the indoor unit and the front panel, be- tween the front panel and the ceiling surface. If there are gaps, the wind may come in and condensation may result. •...
  • Page 10 Please be sure to put the contact address/telephone number on this manual before handing it to the customer. HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN Authorized representative in EU: MITSUBISHI ELECTRIC EUROPE B.V. HARMAN HOUSE, 1 GEORGE STREET, UXBRIDGE, MIDDLESEX UB8 1QQ, U.K. RG79D838H01...

Table of Contents