30" GAS RANGE INSTALLATION INSTRUCTIONS
INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER.
IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE.
READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
OBSERVE ALL GOVERNING CODES AND ORDINANCES.
If the information in this manual is not followed exactly, a fire
or explosion may result causing property damage, personal injury or death.
FOR YOUR SAFETY:
— Do not store or use gasoline or other flammable vapors and liquids in
the vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbor's phone. Follow the gas
supplier's instructions.
If you cannot reach your gas supplier, call the fire department.
— Installation and service must be performed by a qualified installer, service
agency or the gas supplier.
(75.9 cm Min.)
If there is a wall:
5" Min.
(12.7 cm Min cm Min.)
Left side
G
F
Recommended
Grounded
Wall Outlet
Location
Do not pinch the power supply cord between the range
and the wall.
Do not seal the range to the side cabinets.
A. HEIGHT
B. WIDTH
29 7/8"
41 5/8" (105.7 cm) Min.
( 75.9 cm)
42 5/8" (108.3 cm)
Max.
Note: Wiring diagram for this model is enclosed in this booklet (see page 20).
Printed in Canada
29 7/8" Min.
See
note
18" Min.
(45.7 cm Min.)
If there is a wall:
5" Min.
(12.7 cm Min.)
Right side
24" Min.
(61 cm Min.)
24 1/2" Max.
(62.2 cm Max.)
C. DEPTH TO
D. HEIGHT OF
FRONT OF RANGE
27 1/2"
35 3/4" (90.8 cm) Min.
(69.9 cm)
36 3/4" (93.3 cm) Max.
13" Max.
(33 cm Max.)
D
NOTE: 24" (61 cm) minimum clearance between the
cooktop and the bottom of the cabinet when the bottom
of wood or metal cabinet is protected by not less than
1/4" (0.64 cm) flame retardant millboard covered with
not less than No. 28 MSG sheet metal, 0.015" (0.4 mm)
stainless steel, 0.024" (0.6 mm) aluminum, or 0.020"
(0.5 mm) copper.
30" (76.2 cm) minimum clearance when the cabinet is
unprotected.
Figure 1
E. DEPTH WITH
DOOR OPEN
COOKTOP
45 1/2"
(115.6 cm)
1
Refer to your
serial plate for
applicable agency
certification
Note: For
appliances
installed in
the state of
Massachusetts
see page 2.
C
B
E
F. HEIGHT OF
COUNTERTOP
36" (91.4 cm) Standard
35 3/4" (90.8 cm) Min.
P/N 318201775 (1302) Rev. E
English - pages 1-10; Español - páginas 11-19
Wiring Diagram - page 20
A
G. MINIMUM
CUTOUT WIDTH
30 1/16"
(76.4 cm)

Advertisement

Table of Contents
loading

Summary of Contents for Electrolux 30" GAS RANGE

  • Page 1 30" GAS RANGE INSTALLATION INSTRUCTIONS INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER. IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE. READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. OBSERVE ALL GOVERNING CODES AND ORDINANCES. Refer to your If the information in this manual is not followed exactly, a fire serial plate for or explosion may result causing property damage, personal injury or death.
  • Page 2: Important Safety Instructions

    30" GAS RANGE INSTALLATION INSTRUCTIONS IMPORTANT SAFETY Never leave children alone or unattended in the area where an appliance is in INSTRUCTIONS use. As children grow, teach them the proper, safe use of all appliances. Never leave the oven door open when Installation of this range must conform with local codes the range is unattended.
  • Page 3: Model And Serial Number Location

    Those kits can be ordered for purchase through an properly grounded. Electrolux Service Center at 1-877-4ELECTROLUX (1-877- Where a standard 2-prong wall receptacle is installed, 435-3287). it is the personal responsibility and obligation of the consumer to have it replaced by a properly grounded 3-prong wall receptacle.
  • Page 4: Gas Supply Installation

    30" GAS RANGE INSTALLATION INSTRUCTIONS Gas Supply Installation Suggested gas connection GAS FLOW Manual Pressure When shipped from the factory, this unit is designed Flare Flare Shutoff Regulator to operate on 4"(10,16 cm) water column (1.0 kPa) Union Union Valve Natural gas manifold pressure.
  • Page 5: Lp/Propane Gas Conversion

    30" GAS RANGE INSTALLATION INSTRUCTIONS Do not use a flame to check for leaks Range Placement from gas connections. Checking for leaks with a flame may result in a fire or explosion. To eliminate the risk of burns or fire from reaching over heated surface units, cabinet storage space All openings in the wall or floor where the range is to be located above the range should be avoided.
  • Page 6: Range Installation

    30" GAS RANGE INSTALLATION INSTRUCTIONS Check Operation Range Installation Refer to the Use and Care Guide and the Electronic Oven 1. The back of the range may be installed directly Control Guide packaged with the range for operating against the wall. instructions and for care and cleaning of your range.
  • Page 7 30" GAS RANGE INSTALLATION INSTRUCTIONS 4. Adjust the "LOW" Setting of Regular Burner (see 5. Adjust the "LOW" Setting of the Dual Burner figure 8) on the Surface Burner Valves (Figure 9): (see Figure 8) on the Surface Burner Valve (Figure 10): a.
  • Page 8: When All Hookups Are Complete

    It may save you time and expense. The list includes Figure 11 common occurrences that are not the result of defective workmanship or materials in this appliance. Refer to your Use and Care Guide for Electrolux Service phone numbers, or call 1-877-4ELECTROLUX (1-877- 435-3287).
  • Page 9: Important Safety Warning

    30" GAS RANGE INSTALLATION INSTRUCTIONS Important Safety Warning 4. Mark on the floor the location of the mounting holes shown on the template (right and left position). For To reduce the risk of tipping of the range, the range easier installation, 3/16" (4.8 mm) diameter pilot holes must be secured to the floor by the properly installed 1/2"...
  • Page 10 30" GAS RANGE INSTALLATION INSTRUCTIONS NOTES:...
  • Page 11 INSTRUCCIONES DE INSTALACIÓN PARA LA ESTUFA DE GAS LA INSTALACIÓN Y EL SERVICIO DEBEN SER EFECTUADOS POR UN INSTALADOR CALIFICADO. IMPORTANTE: GUARDE ESTAS INSTRUCCIONES PARA USO DEL INSPECTOR LOCAL DE ELECTRICIDAD. LEA Y GUARDE ESTAS INSTRUCCIONES PARA REFERENCIA FUTURA. OBSERVE CÓDIGOS GOBERNANTES Y ORDENANZAS. Si la información contenida en este manual no es seguida exactamente, puede ocurrir un incendio o explosión causando daños materiales, lesión personal o la muerte.
  • Page 12: Importantes Instrucciones De Seguridad

    INSTRUCCIONES DE INSTALACIÓN PARA LA ESTUFA DE GAS IMPORTANTES INSTRUCCIONES • No obstruya el flujo del aire de combustión en la ventilación del horno ni tampoco alrededor de DE SEGURIDAD la base o debajo del panel inferior delantero de la estufa. Evite tocar las aberturas o áreas cercanas Instalación de esta estufa debe cumplir con todos los códigos locales, o en ausencia de códigos locales con el Código de la ventilación, ya que pueden estar muy calientes...
  • Page 13: Requisitos Eléctricos

    INSTRUCCIONES DE INSTALACIÓN PARA LA ESTUFA DE GAS Notas importantes para el Instalador Requisitos eléctricos 1. Lea todas las instrucciones contenidas en este manual antes de instalar la estufa. 120 voltio, 60 Hertzio, circuito dedicado apropiadamente puestos a tierra protegido por un circuito de amperio o 2.
  • Page 14: Instalación De La Alimentación De Gas

    INSTRUCCIONES DE INSTALACIÓN PARA LA ESTUFA DE GAS Las conexiones sugeridas en 30" modelo Instalación de la alimentación de FLUJO DEL GAS Regulador Valvula de cierre de presión Unión Unión Esta unidad ha sido ajustada de fábrica para operar con manual una tubería para gas natural de 4"...
  • Page 15: La Mudanza Del Aparato Para Reparaciones O Limpieza

    INSTRUCCIONES DE INSTALACIÓN PARA LA ESTUFA DE GAS No use flama para verificar que no Estufa - Colocación hayan pérdidas de gas. La comprobación de pérdidas de gas con una flama puede resultar en un incendio o Para eliminar el riesgo de quemaduras explosión.
  • Page 16: Instalación De La Estufa

    INSTRUCCIONES DE INSTALACIÓN PARA LA ESTUFA DE GAS 7.2 Comprobación del Funcionamiento Instalación de la estufa Consulte el Manual del Usuario incluído con la estufa para instrucciones de operación y instrucciones para el 1. La parte trasera de la estufa puede ser directamente cuidado y limpieza de su estufa.
  • Page 17 INSTRUCCIONES DE INSTALACIÓN PARA LA ESTUFA DE GAS 4. Ajuste bajo ("LO") para la válvula de los quemado- 5. Ajuste bajo "LOW" para la válvula de quemador de superficie Dual (vea Figura 8 y 10) res de superficie estandar (Figuras 8 y 9) Nota: En la válvula de quemador triple el ajuste «LOW»...
  • Page 18: Operación De Quemadores Del Horno Y Ajustes De Horno

    INSTRUCCIONES DE INSTALACIÓN PARA LA ESTUFA DE GAS 8.2 Obturador del Aire - Quemador del horno Operación de Quemadores del Horno y La longitud aproximada de la llama del quemador del Ajustes de Horno horno es 1 pulgada (interior claro, llama azul). Para determinar si la llama del quemador de horno es la 8.1 Quemadore de ignición eléctrica adecuada, retire el fondo del horno y el deflector del...
  • Page 19 INSTRUCCIONES DE INSTALACIÓN PARA LA ESTUFA DE GAS Importante Advertencia de Seguridad 4. Marque en el piso la localización de los agujeros de montaje demostrados en la plantilla (posición derecha Para reducir el riesgo de que la estufa se vuelque, es y izquierda).
  • Page 20 WiRiNg DiAgRAM - DiAgRAMA DE LA iNSTALACióN ALáMBRiCA INSTRUCCIONES DE INSTALACIÓN PARA LA ESTUFA DE GAS...

Table of Contents