KENMORE ELECTRIC WALL OVEN INSTALLATION INSTRUCTIONS
INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER.
IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE.
READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors and liquids in
the vicinity of this or any other appliance.
Your new wall oven has been designed to fit a limited variety of cutout sizes to make the job of installing
easier. The first step of your installation should be to measure your current cutout dimensions and
compare them to the cutout dimensions chart below for your model. You may find little or no cabinet
work being necessary.
Do not remove spacers (if equipped) on the side walls and/or on the back of the built-in
oven. These spacers center the oven in the space provided. The oven must be centered to prevent
excess heat buildup that may result in heat damage or fire.
NOTES:
1. Cutout base must be capable of supporting 200 pounds (90 kg).
2. Allow at least 21" (53.3 cm) clearance in front
of oven for door depth when it is open.
3. Dimension G (cutout
depth) is critical to the
proper installation of the
built-in oven. If the oven
decorative trim does not
butt against the cabinet,
or if noise is heard on
convection models, verify
dimension G to assure it is
the required depth.
Door Open
(see note 2)
4. For a cutout height greater than 27
one 2"(5 cm) wide wood shim of appropriate height to
each side of the opening under the appliance side rails.
MODEL
30" (76.2 cm) Wall Oven
MODEL
28½ (72.4)
30" (76.2 cm) Wall Oven
All dimensions are in inches (cm).
Printed in United States
(and Optional Electric or Gas Cooktop Combination)
B
D
A
13
/
" (70.6 cm) add
16
Figure 1 - Single Wall Ovens (Double ovens see Figure 2)
PRODUCT DIMENSIONS
A
30 (76.2)
CUTOUT DIMENSIONS AND CABINET WIDTH
Min.
F Max.
29 (73.7)
1" (2.5 cm)
1" (2.5 cm)
Min.
Min.
C
H
27 3/16"
27 3/16"
(69.1 cm)
(69.1 cm)
31"*
31"*
(78.7 cm)
(78.7 cm)
Spacer
2" (5 cm) Wide Wood
Spacer if Needed
* Suggested distance from floor is 31" (78.7 cm).
Minimum required distance is 4 ½" (11.4 cm)
B
1
29
/
(73.8)
28¼ (71.8)
16
G (Min.)
Min.
27¼ (69.2)
23½ (59.7)
1
I
G
F
1¼"
1¼"
(3.2 cm)
(3.2 cm)
Min.
Min.
Electrical
Junction Box
C
D
24½ (62.2)
I
.
H Max
28½ (72.4)
30
1
/
(76.5) Min
8
P/N 318201522 (0602) Rev. A
English – pages 1-10
Español – páginas 11-20
Hole
for Cable
3"
3"
(7.6 cm)
(7.6 cm)