Digital Multiplexer CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION : TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. Graphic Symbol Explanation The lightning flash with arrowhead symbol, within an equilat- eral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltage”...
Page 3
Digital Multiplexer 8A. An appliance and cart combination should be moved with care. Quick stops, excessive force, and uneven surfaces may cause the appliance and cart combination to overturn. Ventilation : Slots and openings in the cabinet are provided for ventilation and to ensure reliable operation of the video product and to protect it from overheating, and these openings must not be blocked or covered.
Digital Multiplexer CONTENTS CHAPTER 1. INTRODUCTION..........1-1~1-4 Introduction.......................1-1 Functions and Features ...................1-1 Name of parts and Function ................1-2 Front panel......................1-2 Rear panel......................1-4 CHAPTER 2. INSTALLATION ..........2-1~2-4 Preparing for the Installation ................2-1 Precautions when Installing ................2-2 Unpacking......................2-4 CHAPTER 3. CONNECTING TO OTHER DEVICES ..... 3-1~3-6 Connecting to normal VCR and Monitor............3-1 Connecting to S-VHS VCR and S-VHS MONITOR.
Page 5
Digital Multiplexer CHAPTER 5. SETTING OF PROGRAM MENU ....5-1~ 5-10 Record setting of each camera ...............5-1 Setting of display mode..................5-3 Setting of title by channel.................5-5 Setting of display mode for current time, year, month and date .....5-6 Setting of alarm ....................5-7 Setting of motion .....................5-7 System setting....................5-9 CHAPTER 6.
Digital Multiplexer CHAPTER 1.INTRODUCTION Introduction This unit can combine up to 16 Camera Images onto one VCR, and both frequent recording and sequential recording can be possible in the unit of Frame and Field, and assigned channel can be played back selectively, and it is Triplex with which Live Mode, Playback Mode, and Live plus Playback Mode can be done in one monitor.
Digital Multiplexer Name of parts and Function FRONT PANEL A. POWER SWITCH Power ON/OFF. B. MULTI SCREEN DISPLAY - MULTI SCREEN You are in the multi-screen mode. Each press of the MULTI SCREEN Button shows the picture displayed. - REC CHECK LIVE MODE: VCR output is displayed on the monitor.
Page 8
Digital Multiplexer E. SETUP/FUNCTION - MENU Pressing this Button will make LED lit, and MAIN MENU appears on the screen. - ENTER Used when switching from MAIN MENU to SUB MENU. - SET This function is used when moving from SUB MENU to MAIN MENU after setting programs on each MENU screen, or is used when setting each channel for multi-screen.
Page 9
Digital Multiplexer PANEL TRASERO -AC IN A.CAMERA INPUT / LOOP THROUGH OUT - Up to 16 camera signals can be input. When transmitting camera signals to external devices, OUT terminal can be used. B.ALARM IN / ALARM OUT / VTI TERMINAL - VTI: TRIGGER Output Connection terminal of VCR - ALARM IN: Up to 16 ALARM Sensors can be connected.
Digital Multiplexer CHAPTER 2. INSTALLATION Preparing for the Installation The following information is prepared for safe installation of the unit. This unit can be placed on a flat table or installed in the rack. It should not be used vertically or skew, but horizontally.
Digital Multiplexer Precautions when Installing Precautions when Installing ¥ Be sure to turn the unit off before installing. ¥ Avoid shock or vibration since they may cause unit malfunction. ¥ Keep away from magnets, radio or TV to avoid magnetic damage.
Page 12
Digital Multiplexer ¥ When replacing built-in fuse, be sure to turn the power off, and unplug the unit. ¥ Avoid locating the unit where direct sunlight will fall, and main- tain it cool. Keep tools and equipment away from people so that they would not be hurt.
Digital Multiplexer UNPACKING Place shipping container on a flat surface, cut straps or tape, open top. Then, review the content; the following items should be included: ¥ Main Unit ¥ User Manual (this document) ¥ One (1) Power Unit ¥ Two Rack Mount Adaptors...
Digital Multiplexer CHAPTER 3. Connecting to Other Devices This unit can be connected to other devices such as monitor, camera, VCR, and PC. This chapter describes how to connect the unit to other devices. CAUTIONS Be sure that voltages higher than 2 VDC should not be input to the input terminal of Camera and Video. 1.
Digital Multiplexer 3. Connecting to TIME LAPSE VCR When connecting the unit to the TIME LAPSE VCR, set “TLV” in “REC TYPE” after selecting “1.REC OUT SET” of SETUP MENU. 1. Connect a S-JACK cable to the VTI terminal on the Unit’s Rear Panel and to the REC TRIG OUT terminal on the VCR.
Digital Multiplexer 4. Connecting to ALARM SENSOR 1. Connect the ALARM terminal on the Unit’s Rear Panel to the SENSOR CORRESPONDING TO cam- era number. 2. Connect grounding wires. 3. Connect the HOT terminal on the Unit’s Rear Panel to the ALARM IN terminal on the VCR. 4.
Digital Multiplexer 5. Remote Control by connecting to PC A. Connecting to RS-232C The unit can be remote-controlled by connecting to PC in which terminal emulation program is built. At this time, RS-232C Cable is used for connection. When connecting to the PC by RS-232C, some keys on the PC keyboard can be used as Function Buttons on the Unit’s Front Panel.
Digital Multiplexer B. Connecting to RS485 RS485 DATA + DATA - Connecting RS485 and DATA PROTOCOL 1. Communication Method Data Transmission Type : RS485 Protocol : 8 bit data, 1 Stop bit, None Parity Transmission Speed: 4800, 9600, 19200, 38400 bps 2.Data Format 9Byte Fixed byte...
Digital Multiplexer Chapter 4. Basic Method to use Initial operation 1. Turn on power switch. A 4-division screen appears on the monitor if firstly operating after purchase. In this case, the channel with- out inputting appears in the blue background on the screen and a video loss occurs. (The current operation status is memorized when the power turns off after completing the initial setting and thus the unit operates in the operation status when the power turns off if turning power on.) 2.
Digital Multiplexer When desiring to see in the FULL screen The FULL screen may be seen in the live and tape replay mode, available for 16 channels from No.1 through No.16. Method to use. Press the camera select button of the desired channel. The camera select button does not operate in the following cases: - In setting of program mode - In displaying ALARM/LOSS LIST on screen...
Digital Multiplexer When desiring to see automatic sequential conversion screen The automatic sequential conversion mode operates in the LIVE screen status and consists of the follow- ing 2 cases: The FULL screen is converted if pressing the “SEQUENCE” button in the FULL screen status. The screen on the bottom right side is converted if pressing the “SEQUENCE”...
Digital Multiplexer When desiring to see the stop screen The monitor screen (full screen and division) may be seen with a temporary stop. A desired screen may be temporarily stopped selectively in the division screen indication mode. 1. FREEZE setting of FULL screen The LED turns on and monitor image stops and “FREEZE”...
Digital Multiplexer When desiring to see in the PIP screen The PIP (picture in picture) screen may be seen using the “PIP” button on the FULL screen in the LIVE mode. The size of the PIP sub-screen is set in the “PIP SIZE” of the “2. MON OUT SET” on the program menu.
Digital Multiplexer Chapter 5. Setting of Program Menu <MAIN MENU> The following main menu is displayed on the monitor screen if pressing “MENU” button, the “MENU” LED turns on. The LED turns off if pressing the button and it returns to the previous status. [SETUP MENU] 1.
Page 26
Digital Multiplexer - The following screen is displayed if pressing the “ENTER” button with the blinking position placed at the “DUTY SET ….”. [REC DUTY SET] CH1 : 1 CH3 : 1 CH5 : 1 CH7 : 1 CH9 : 1 CH10 : 1 CH11 : 1 CH12 : 1...
Digital Multiplexer 2. Setting of display mode You can set LIVE/PB display type, PIP size, sequence, and border color, PB IN, etc.. The following screen is displayed if pressing the “ENTER” button with the blinking position placed at the “2. MON OUT SET” by pressing “MOVE” button on the main menu. [MON OUT SET] LIVE DISPLAY ALL PB DISPLAY...
Page 28
Digital Multiplexer - The following is displayed if pressing the “ENTER” button with the blinking position placed at the “SPOT OUT...”: [SPOT OUT] : 02 : 00 : 00 : 00 : 00 : 00 : 00 : 00 : 00 CH10 : 00 CH11 : 00 CH12 : 00...
Digital Multiplexer - The following screen is displayed if pressing the “ENTER” button with the blinking position placed at the “LOSS DETECT….”: [LOSS DETECT] CH1 : ON CH2 : ON CH3 : ON CH4 : ON CH5 : ON CH6 : ON CH7 : ON CH8 : ON CH9 : ON...
Digital Multiplexer [TITLE SET] Characters available for inputting (the blinking 0123456789ABCDEFGH characters may be input and the empty space IJKLMNOPQRSTUVWXYZ between “Z” and “[“ means blanking.) [ ] X + / : Position of currently input character (blinking) CH 1: ---CH1---- ¥...
Digital Multiplexer 5. Setting of alarm Set operation when alarm occurs. The following screen is displayed if pressing the “ENTER” button with the blinking indication placed at the “5.ALARM SET” by pressing the “MOVE” button on the main menu screen: [ALARM SET] HOLD TIME 01 MIN...
Page 32
Digital Multiplexer - The blinking character moves if pressing “ ”, “ ” button. - The setting value is changed if pressing “ ”, “ ” button. SENSITIVITY: OFF MEDIUM HIGH ¥ Set sensitivity of motion detection. ¥ Do not perform motion detection if “OFF”. AREA SET: CH1 ~ CH16 ¥...
Digital Multiplexer 7. System setting Set application of password change, buzzer and summer time. The following screen is displayed if pressing the “ENTER” button with the blinking indication placed at the “7. SYSTEM SET” on the main menu screen: [SYSTEM SET] RS-485 ADDR SET 0 BAUD RATE 38400...
Page 34
Digital Multiplexer - The following screen is displayed if pressing the “ENTER” button when the blinking position is at the “PASSWORD CHANGE…”: [PASSWORD CHANGE] PASSWORD CHECK - - - - - - - - NEW PASSWORD - - - - - - - - CONFIRM - - - - - - - - ¥...
Digital Multiplexer Chapter 6. Recording 1.Normal record mode When setting the “REC TYPE” of the setup menu “1.REC OUT SET” to “NOR”. (1) Frame record - When setting the “REC TYPE” of the setup menu “1.REC OUT SET” to FRAME. - The image signal entered from the maximum 16 cameras is output in Frame and recorded on the VCR.
Digital Multiplexer 3.Weight value (REC DUTY) record - Used to record weight value (record frequency is more than the channel whose duty is low) for the impor- tant channel. - Perform the weight value record using the REC duty (OFF, 1~5) by channel set from the “REC DUTY” of the “1.REC OUT SET”...
Digital Multiplexer Chapter 7. Occurrence and handling of alarm, loss, motion 1.Alarm occurrence conditions The following events occur if alarm occurs since the sensor is connected to the alarm input terminal on the backside: 1) Warning sounds (if buzzer turns “ON”). 2) Alarm information (date and time when alarm occurs) is recorded on the alarm list.
Digital Multiplexer 6.Alarm/Loss list reference If pressing the “LIST” button on the front, alarm, channel loss and motion detection information recently occurred is output up to 100EA (10EA x 10 page) on screen in the occurrence as follows: Current page/ current page [ALARM/LOSS LIST] [ALARM/LOSS LIST] [ALARM/LOSS LIST]...
Digital Multiplexer Appendix B Checking points in trouble There may be a case not to use system properly since unexpected status occurs while using the system. In this case, such status is actually caused by a critical error in system but a simple first-aid can solve this status in the most case.