Air-Conditioners For Building Application

INDOOR UNIT

PKFY-P·VKM-E
PLFY-P·VCM-E2
PCFY-P·VKM-E
OPERATION MANUAL
For safe and correct use, please read this operation manual thoroughly before operating the air-conditioner unit.
BEDIENUNGSHANDBUCH
Zum sicheren und einwandfreien Gebrauch der Klimaanlage dieses Bedienungshandbuch vor Inbetriebnahme
gründlich durchlesen.
MANUEL D'UTILISATION
Pour une utilisation correcte sans risques, veuillez lire le manuel d'utilisation en entier avant de vous servir du
climatiseur.
BEDIENINGSHANDLEIDING
Voor een veilig en juist gebruik moet u deze bedieningshandleiding grondig doorlezen voordat u de
airconditioner gebruikt.
MANUAL DE INSTRUCCIONES
Lea este manual de instrucciones hasta el final antes de poner en marcha la unidad de aire acondicionado
para garantizar un uso seguro y correcto.
ISTRUZIONI DI FUNZIONAMENTO
Leggere attentamente questi istruzioni di funzionamento prima di avviare l'unità, per un uso corretto e sicuro
della stessa.
EΓXEIPIΔIO OΔHΓIΩN XPHΣEΩΣ
Για ασφάλεια και σωστή χρήση, παρακαλείστε διαβάσετε προσεχτικά αυτό το εγχειρίδιο χρήσεως πριν θέησετε
σε λειτουργία τη μονάδα κλιματισμού.
MANUAL DE OPERAÇÃO
Para segurança e utilização correctas, leia atentamente o manual de operação antes de pôr a funcionar a
unidade de ar condicionado.
Işletme Elkitabı
Emniyetli ve doğru biçimde nasıl kullanılacağını öğrenmek için lütfen klima cihazını işletmeden önce bu
elkitabını dikkatle okuyunuz.
РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ
Для обеспечения правильного и безопасного использования следует ознакомиться с инструкциями,
указанными в данном руководстве по эксплуатации, тщательным образом до того, как приступать к
использованию кондиционера.
FOR USER
FÜR BENUTZER
POUR L'UTILISATEUR
VOOR DE GEBRUIKER
PARA EL USUARIO
PER L'UTENTE
ΓΙΑ ΤΟΝ ΧΡΗΣΤΗ
PARA O UTILIZADOR
KULLANICI İÇİN
ДЛЯ ПОЛЬЗОВАТЕЛЯ
English (GB)
Deutsch (D)
Français (F)
Nederlands (NL)
Español (E)
Italiano (I)
Ελληνικά (GR)
Português (P)
Türkçe (TR)
Русский (RU)

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric PKFY-P-VKM-E

  • Page 1: Indoor Unit

    Air-Conditioners For Building Application INDOOR UNIT PKFY-P·VKM-E PLFY-P·VCM-E2 PCFY-P·VKM-E OPERATION MANUAL FOR USER English (GB) For safe and correct use, please read this operation manual thoroughly before operating the air-conditioner unit. BEDIENUNGSHANDBUCH FÜR BENUTZER Deutsch (D) Zum sicheren und einwandfreien Gebrauch der Klimaanlage dieses Bedienungshandbuch vor Inbetriebnahme gründlich durchlesen.
  • Page 2: Table Of Contents

    2006/66/EC Article 20 Information for end-users and Annex II. Your MITSUBISHI ELECTRIC product is designed and manufactured with high quality materials and components which can be recycled and/or reused. This symbol means that electrical and electronic equipment, batteries and accumulators, at their end-of- life, should be disposed of separately from your household waste.
  • Page 3: Parts Names

    2. Parts Names Indoor Unit PKFY-P·VKM-E PLFY-P·VCM-E2 PCFY-P·VKM-E Fan speed 2 speed 3 speed 4 speed+ Auto* Steps 4 steps 4 steps 5 steps Vane Auto Swing ― Louver Manual Manual Filter Normal Long-life Long-life Filter cleaning indication 100 hr 2,500 hr 2,500 hr * This operation is available only using the remote controller...
  • Page 4: Operation Section

    2. Parts Names “Sensor” indicator Wired Remote-Controller (Optional parts) Displayed when the remote controller Display Section sensor is used. Day-of-Week For purposes of this explanation, Shows the current day of the week. all parts of the display are shown as lit. During actual operation, Time/Timer Display “Locking function”...
  • Page 5 2. Parts Names Wireless Remote-Controller (Optional parts) Transmission area Transmission indicator Remote controller display Timer indicator * For explanation purposes, all of the items that appear in the display are shown. * All items are displayed when the Reset button is pressed. Operation areas ON/OFF button Temperature set buttons...
  • Page 6: Screen Configuration

    3. Screen Configuration <Screen Types> For details on setting the language for the remote controller display, refer Set Day/Time Function Selection of remote controller to section 8. Function Selection. TIME SUN The initial language setting is English. Function Selection of remote controller: Set the functions and ranges available to the remote controller (timer functions, operating restrictions, etc.)
  • Page 7 5. Operation <To Stop Operation> 5.4. Fan speed setting Press the ON/OFF button 1 again. Press the Fan Speed button 5 as many times as necessary while the • The ON lamp 1 and the display area go dark. system is running. •...
  • Page 8 5. Operation 5.5. Airflow up/down direction setting 5.6. Ventilation <To change the airflow up/down direction> For LOSSNAY combination 5.6.1. For Wired Remote-controller With the unit running, press the Airflow up/down button 6 as necessary. To run the ventilator together with the indoor unit: •...
  • Page 9: Timer

    6. Timer 6.1. For Wired Remote-controller <How to Set the Weekly Timer> 1. Be sure that you are at a standard control screen, and that the weekly You can use Function Selection of remote controller to select which of timer indicator 1 is shown in the display. three types of timer to use: 1 Weekly timer, 2 Simple timer, or 3 Auto 2.
  • Page 10 6. Timer 7. Press the appropriate Temperature set button 3 to set the desired 6.1.2. Simple Timer temperature (at 7). You can set the simple timer in any of three ways. • Start time only: * Each press changes the setting, in the following sequence: No The air conditioner starts when the set time has elapsed.
  • Page 11 6. Timer 7. After completing steps 3 to 6 above, press the Filter button 4 to Example 2: lock in the value. Start the timer, with OFF time is sooner than ON time Note: ON Setting: 5 hours Your new settings will be cancelled if you press the Operation mode (Back) OFF Setting: 2 hours button 2 before pressing the Filter button 4.
  • Page 12: Other Functions

    6. Timer <Checking the Current Auto Off Timer Setting> 6.2. For wireless remote controller Timer Setting TIMER AFTER AUTO OFF 1. Be sure that the “Auto Off” is visible on the screen (at 1). 2. Hold down the Timer Menu button 2 for 3 seconds, so that “Monitor” is indicated on the screen (at 4).
  • Page 13: Function Selection

    7. Other Functions 7.2. Error Codes indication ERROR CODE ON lamp ON/OFF (Flashing) Error Code Indoor Unit No. If you have entered contact number to be called in the event of a problem, the screen displays this number. (You can set this up under Function Selection of remote controller. For information, refer to section 8.) If the ON lamp and error code are both flashing: This means that the air conditioner is out of order and operation has been stopped (and cannot resume).
  • Page 14 8. Function Selection Normal display [Function selection flowchart] (Display when the air condition is not running) Setting language (English) Hold down the E button and press the D button for 2 seconds. E Press the operation mode button. Hold down the E button and press the D button for 2 seconds. G Press the TIMER MENU button.
  • Page 15 8. Function Selection [Detailed setting] [4]–3. Operation mode selection setting (1) Remote controller main/sub setting [4]–1. CHANGE LANGUAGE setting • To switch the setting, press the [ ON/OFF] button D. The language that appears on the dot display can be selected. 1 Main: The controller will be the main controller.
  • Page 16 8. Function Selection [Dot display table] Selecting language English German Spanish Russian Italian Chinese French Japanese Waiting for start-up Operation mode Cool Heat Auto Auto(Cool) Auto(Heat) Ventilation Stand by (Hot adjust) Defrost Set temperature Fan speed Not use button Check (Error) Test run Self check Unit function selection...
  • Page 17: Emergency Operation For Wireless Remote-Controller

    9. Emergency Operation for Wireless Remote-controller When the remote controller cannot be used PKFY-P·VKM-E When the batteries of the remote controller run out or the remote controller malfunctions, the emergency operation can be done using the emergency buttons on the grille. A DEFROST/STAND BY lamp B Operation lamp C Emergency operation cooling switch...
  • Page 18 10. Care and Cleaning PKFY-P·VKM-E PLFY-P·VCM-E2 1 Using both hands, pull both the bottom corners of the inlet grille to open the grille, then lift the filter until it clicks at the stop position. 2 Hold the knobs on the filter and pull the filter up, then pull it out 1 Pull the knob on the intake grille in the direction indicated by the downward.
  • Page 19: Troubleshooting

    11. Troubleshooting Having trouble? Here is the solution. (Unit is operating normally.) Air conditioner does not heat or cool well. Clean the filter. (Airflow is reduced when the filter is dirty or clogged.) Check the temperature adjustment and adjust the set temperature. Make sure that there is plenty of space around the outdoor unit.
  • Page 20 11. Troubleshooting Having trouble? Here is the solution. (Unit is operating normally.) Noise is louder than specifications. The indoor operation sound level is affected by the acoustics of the particular room as shown in the following table and will be higher than the noise specification, which was measured in an echo-free room.
  • Page 21: Specifications

    12. Specifications Model PKFY-P63VKM-E PKFY-P100VKM-E Power source (Voltage<V>/Frequency) <Hz> ~N/220-230-240/50, 220/60 Capacity (Cooling/Heating) <kW> 7.1/8.0 11.2/12.5 Dimension (Height) <mm> Dimension (Width) <mm> 1170 Dimension (Depth) <mm> Net weight <kg> Fan Airflow volume (Low-High) <m /min> 16-20 20-25 Noise level (Low-High) <dB>...
  • Page 22 Please be sure to put the contact address/telephone number on this manual before handing it to the customer. HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN Printed in Thailand RG79Y571H01...

This manual is also suitable for:

Pcfy-p-vkm-ePlfy-p-vcm-e2