hit counter script
LG LP0814WNR Owner's Manual

LG LP0814WNR Owner's Manual

Portable air conditioner
Hide thumbs Also See for LP0814WNR:

Advertisement

For service questions, contact LG at 1-800-243-0000.
For sales inquiries, contact Sylvane at 1-800-934-9194 or
visit www.sylvane.com.
OWNER'S MANUAL

AIR CONDITIONER

Please read this manual carefully before operating
your air conditioner and retain it for future reference.
TYPE PORTABLE AIR CONDITIONER
MODEL LP0814WNR
www.lgappliances.com

Advertisement

Table of Contents
loading

Summary of Contents for LG LP0814WNR

  • Page 1: Air Conditioner

    For service questions, contact LG at 1-800-243-0000. For sales inquiries, contact Sylvane at 1-800-934-9194 or visit www.sylvane.com. OWNER’S MANUAL AIR CONDITIONER Please read this manual carefully before operating your air conditioner and retain it for future reference. TYPE PORTABLE AIR CONDITIONER MODEL LP0814WNR www.lgappliances.com...
  • Page 2: Table Of Contents

    Key Parts and Components ....8 Congratulations on your purchase and welcome to the LG family. HOW TO USE Before Using Your Air Conditioner .
  • Page 3: Important Safety Instructions

    I M P O R T A N T S A F E T Y I N S T R U C T I O N S BASIC SAFETY PRECAUTIONS Do not store flammables like gasoline benzene thinner etc. near the air conditioner.
  • Page 4 I M P O R T A N T S A F E T Y I N S T R U C T I O N S Unplug the unit when not using it for a long time.
  • Page 5 I M P O R T A N T S A F E T Y I N S T R U C T I O N S Hold the plug by the head When gas leaks, open the window for ventilation before not the cable when taking it out.
  • Page 6: Electrical Safety

    I M P O R T A N T S A F E T Y I N S T R U C T I O N S If the liquid from the battery gets onto your skin If you eat the liquid from the battery,brush or clothers wash it well with clean water.
  • Page 7 RESET button will not stay engaged, unplug the air conditioner immediately and contact your LG service technician. Due to potential safety hazards, the use of TEMPORARY GROUNDING an adapter plug is strongly discouraged.
  • Page 8: Parts And Features

    P A R T S A N D F E A T U R E S KEY PARTS AND COMPONENTS AIR DISCHARGE The direction of air can be controlled wherever you want to cool by adjusting the horizontal louver. The horizontal direction is adjusted by moving the lever to the left or right.
  • Page 9: How To Use

    H O W T O U S E BEFORE USING YOUR AIR CONDITIONER PREPARING FOR OPERATION UNPACKING THE AIR CONDITIONER Refer to the Installation Instructions included in Remove and store packing materials for reuse. this manual before using the air conditioner. Remove any shipping tape before using the Once the air conditioner has been properly air conditioner.
  • Page 10: Before Using Your Air Conditioner

    H O W T O U S E BEFORE USING YOUR AIR CONDITIONER INSERTING BATTERIES IN THE REMOTE Before using your remote, install the provided AAA batteries. Press and glide the battery cover on the back Be sure to note of the remote, then you can remove the cover.
  • Page 11: Control Panel And Remote

    H O W T O U S E CONTROL PANEL AND REMOTE Timer Operation of functions is the same when using the remote or the control panel, unless otherwise stated. NOTE: The remote sensor is located under the LED display. Point the remote anywhere at the sensor.
  • Page 12 Plug in, the LED display will light When you plug the power cord into grounded outlet, LED display will show room temperature.
  • Page 13: Installation Instructions

    I N S T A L L A T I O N I N S T R U C T I O N S PREPARING FOR INSTALLATION WARNING The air conditioner is heavy! Use two or more people to lift and install the unit! Failure to do so could result in back injury or other injuries. Panel B (9’’) EXHAUST COMPONENTS The following components are used for window venting.
  • Page 14: Selection Of Installation Location

    I N S T A L L A T I O N I N S T R U C T I O N S SELECTION OF INSTALLATION LOCATION Place the unit on a level floor. For best performance,allow at least 20 in of air space on all sides of the unit for good air circulation.
  • Page 15: Window Vent Panel And Extensions

    I N S T A L L A T I O N I N S T R U C T I O N S WINDOW VENT PANEL AND EXTENSIONS The window installation kit allows you to install the air conditioner in most vertical-sliding windows 18"...
  • Page 16: Installation In Vertical Sliding Windows

    I N S T A L L A T I O N I N S T R U C T I O N S INSTALLATION IN VERTICAL SLIDING WINDOWS Insert the diffuser into the Vent Panel. And then slide. Small gap Type C screw Second Slide...
  • Page 17: Installation In Casement Style Windows

    I N S TA L LA T I O N I N S T R U C T I O N S INSTALLATION IN CASEMENT STYLE WINDOWS NOTE: The window installation kit can be used with casement windows between 18 ″ and 50 ″ tall. Foam seal C (Adhesive type-shorter)
  • Page 18 I N S T A L L A T I O N I N S T R U C T I O N S INSTALLATION IN CASEMENT STYLE WINDOWS Insert the diffuser into the Vent Panel. And then slide. Small gap Type C screw Second Slide...
  • Page 19: Care And Cleaning

    C A R E A N D C L E A N I N G EMPTYING THE WATER COLLECTION TANK Using the bottom drain port When the internal water collection tank is full, FL will appear in the display and the air conditioner will turn off until the tank is emptied.
  • Page 20: Cleaning The Case

    C A R E A N D C L E A N I N G CLEANING THE CASE Wipe the case with a slightly damp cloth, then wipe dry with a dry cloth or towel. • To prevent damage to the finish, do not use gasoline, benzene, thinner, etc., or any abrasive cleansers to clean the air conditioner;...
  • Page 21: Storing The Air Conditioner

    C A R E A N D C L E A N I N G STORING THE AIR CONDITIONER Before using the air conditioner again: If the air conditioner will not be used for an extened period of time: To drain the water collection tank completely, Make sure the filter and drain cap are leave the bottom drain cap off long enough to in place...
  • Page 22: Troubleshooting

    T R O U B L E S H O O T I N G BEFORE CALLING FOR SERVICE Before you call for service, review this list. It may save you time and expense. This list includes common occurrences that are not the result of a defect in workmanship or materials. Make sure the air conditioner plug is pushed The air conditioner is completely into the outlet.
  • Page 23: Before Calling For Service

    Short or open circuit in the Unplug the air conditioner and contact your indoor air thermistor. authorized LG service center. Short or open circuit in the Unplug the air conditioner and contact your indoor pipe thermistor. authorized LG service center.
  • Page 24 I N S T A L L A T I O N I N S T R U C T I O N S INSTALLATION IN VERTICAL SLIDING WINDOWS NOTE: The window installation kit can be used with vertical sliding windows between 18"...
  • Page 25: Warranty

    (90) days, whichever is longer. Please retain dated receipt or delivery ticket as evidence of the Date of Purchase for proof of warranty (you may be required to submit a copy to LG or authorized representative).
  • Page 26 For service questions, contact LG at 1-800-243-0000. For sales inquiries, contact Sylvane at 1-800-934-9194 or visit www.sylvane.com. LG Customer Information Center 1-800-243-0000 Register your product Online LG ELECTRONICS,INC. www.lgappliances.com 1000 Sylvan Ave.,Englewood Cliffs,NJ 07632...

Table of Contents

Save PDF