Job Name/Location:
Date:
PO No.:
Architect:
Engr:
Rep:
(Company)
ARNU423BGA2
Multi V™ Ducted (High Static)
42,000
Btu/h Indoor Unit
Performance:
Total Cooling Capacity (Btu/h)
Heating Capacity (Btu/h)
Power Input¹ (W)
Cooling Nominal Test Conditions:
Indoor:
80°F DB/67°F WB
Outdoor
95°F DB
:
Electrical:
Power Supply (V/Hz/Ø)
Rated Amps (A)
Piping:
Refrigerant:
Liquid Line (in, OD)
Vapor Line (in, OD)
Condensate:
Condensate Line (in,OD)
Factory Installed Pump²
Controls Features:
•Auto changeover
(Heat Recovery only)
•Auto opera on
•Auto restart
•Child lock
•Dual thermistor control
•Group control
•E.S.P. control
Optional Accessories:
Wireless Handheld Remote Controller ‐ PQWRHDF0
7‐Day Programmable Controller (Black) ‐ PQRCVSL0
7‐Day Programmable Controller (White) ‐ PQRCVSL0QW
Simple Controller with Mode (Black) ‐ PQRCVCL0Q
Simple Controller with Mode (White) ‐ PQRCVCL0QW
Simple Controller without Mode (Black) PQRCHCA0Q
Simple Controller without Mode (White) ‐ PQRCHCA0QW
Dry Contact Unit ‐ PQDSB1
Dry Contact Unit ‐ PQDSBC
Wall Mounted Temperature Sensor ‐ PQRSTA0
For continual product development, LG reserves the right to change specifications without notice.
LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG Life's Good" is a registered trademark of LG Corp. /www.lg‐vrf.com
For:
File
Approval
GC:
Mech:
(Project Manager)
42,000
43,800
450
Heating Nominal Test Conditions:
Indoor:
70°F DB
Outdoor
47°F DB/43°F WB
:
208‐230/60/1
2.3
3/8 Flare
5/8 Flare
1
Yes
•Hot start
•Self diagnos cs
•Sleep mode
•Timer (on/off)
•Weekly schedule
•So dry (dehumidifica on)
•Fan speed control
³
Tag #:
Resubmit
Other
Entering Mixed Air:
Cooling Max⁴ (°F WB)
Heating Min (°F DB)
Unit Data:
Refrigerant Type
Refrigerant Control
Sound Pressure⁵ dB(A) (H/M/L)
Filter
Net Unit Weight (lbs)
Shipping Weight (lbs)
Fan:
Type
Quantity
Motor/Drive
Airflow Rate H/M/L (CFM)
External Static Pressure⁶ (in wg)
Standard Features:
•Limited Warranty with LG Cer fied Installa on
•Two Year Functional Parts Warranty
Notes:
1.The Power Input is rated at high speed.
2.Maximum li is 27 in from bo om of unit.
3.Requires a 7‐Day programmable controller.
4.See Engineering Manual for sensible and latent capaci es.
5.Sound Pressure levels are tested in an anechoic chamber under ISO Standard 1996.
6.Factory set as standard.
7.All communica on cable to be minimum 18 AWG, 2‐conductor, stranded, shielded and must
comply with applicable local and national code.
8.Power wiring cable size must comply with the applicable local and na onal code.
9.This unit comes with a dry nitrogen charge.
10.This data is rated 0 above sea level, with 25 of refrigerant line per indoor unit and a 0
level difference between outdoor and indoor units. All capacities are net with a combination
ratio between 95 – 105%.
11.Must follow installa on instruc ons in the applicable LG installa on manual.
R410A
48/46/45
Washable Pre‐filter
Sirocco
Brushless Digitally Controlled/Direct
1,218/1,141/1,084
VRF‐SB‐DF‐009‐US 012C19
Page 1 of 2
76
59
EEV
84
95
1
0.39