PLC-WM5500/WM5500L Expand Serial Command Functional Specifications Overview 0û This Functional Specification defines communication with PJ-Net organizer for PLC-WM5500 / WM5500L. 0û Supporting Firmware Ver. 1.x of the projector. 0û Commands in this document are to communicate with PJ-Net organizer, but most commands are used to control a projector remotely from a computer with RS-232C.
PLC-WM5500/WM5500L Expand Serial Command Functional Specifications Notes for communication Expand Serial Command is defined as a single command per line that starts with “C” and ends with carriage return (0x0D). There are two types of commands; Functional Execution Commands and Status Read Command.
PLC-WM5500/WM5500L Expand Serial Command Functional Specifications Functional Execution Command Table 5.1 Image Command Table Item Execute command CF_BRIGHT_%1 [CR] Set value of Brightness CF_CONT_%1 [CR] Set value of Contrast CF_COLOR_%1 [CR] Set value of Color CF_TINT_%1 [CR] Set value of Tint CF_SHARP_%1 [CR] Set value of Sharpness CF_GAMMA_%1 [CR]...
PLC-WM5500/WM5500L Expand Serial Command Functional Specifications Screen Control Command Table Execute command Item CF_SCREEN_%1 [CR] Select Screen size CF_DZCENT _%1 [CR] Cancel Digital Zoom mode CF_VSCALE_%1[CR] Set V Scale CF_VPOS_%1[CR] Set V Position CF_HSCALE_%1[CR] Set H Scale CF_HPOS_%1[CR] Set H Position CF_KEYSTONE _%1 [CR] Set Keystone correction CF_KYSTNMODE _%1 [CR]...
PLC-WM5500/WM5500L Expand Serial Command Functional Specifications CF_FILSCRL_%1[CR] Reset Filter scroll counter CF_FANSPEED_%1 [CR] Set level of Fan Speed CF_SIMPLEMODE_%1 [CR] Set Simple mode function CF_RCODE_%1 [CR] Select Remote Control Code Select location of infrared remote receiver of remote CF_RSENS_%1 [CR] control CF_P-MANE_%1 [CR] Set Power Management function...
PLC-WM5500/WM5500L Expand Serial Command Functional Specifications Status Read Command Table Image Status Read Command Table Status Read command Item CR_BRIGHT [CR] Get value of Brightness CR_CONT [CR] Get value of Contrast CR_COLOR [CR] Get value of Color CR_TINT [CR] Get value of Tint CR_SHARP [CR] Get value of Sharpness CR_GAMMA [CR]...
PLC-WM5500/WM5500L Expand Serial Command Functional Specifications CR_IDSLOT1[CR] Get ID information of Input1 CR_IDSLOT2[CR] Get ID information of Input2 CR_IDSLOT3[CR] Get ID information of Input3 CR_IDSLOT4[CR] Get ID information of Input4 Screen Status Read Command Table Status Read command Item CR_SCREEN [CR] Get selected screen size CR_VSCALE[CR] Get setting status of V Scale...
PLC-WM5500/WM5500L Expand Serial Command Functional Specifications CR_FILH[CR] Get Filter used time Get time to display Filter cleaning / replacement warning on CR_FILTIMER[CR] screen CR_FILCOND[CR] Get status of filter clog CR_FILREPL[CR] Get status of Filter cleaning / replacement time CR_FANSPEED [CR] Get selected Fan Control Speed CR_SIMPLEMODE [CR] Get selected mode in Simple mode function...
PLC-WM5500/WM5500L Expand Serial Command Functional Specifications Error Code Table Error Code Contents -When the received data cannot be decoded -Parameter designation error (wrong digit number, including invalid value, etc.) Normal reception (This is “Not” error) The function is not available in the selected Mode Selected value is out of range (Not reflected) Command mismatched to Hardware (the command is for Optional function which is not implemented)
PLC-WM5500/WM5500L Expand Serial Command Functional Specifications Functional Execution Command 8.1 Format 1) PC issues commands in format as below: Pattern1: “CF_ COMMAND” [CR] Pattern2: “CF_ COMMAND _” %1 [CR] CF_: Header COMMAND: String %1: Parameter (String) _: Space (To separate COMMAND and Parameter) 2) The projector decodes the received command and when it is ready to receive the next command, it returns the response.
PLC-WM5500/WM5500L Expand Serial Command Functional Specifications Image Command 8.4.1 CF_ BRIGHT Command Command “CF_BRIGHT_%1” [CR] “000-063”--------------- Directly specify setting value of Brightness “UP”--------------------- Increment setting value of Brightness by 1 “DN”--------------------- Decrement setting value of Brightness by 1 Set user controlled value of Brightness (Available only in the normal Power ON status) Details The value set by this command will not be stored in the projector’s memory.
PLC-WM5500/WM5500L Expand Serial Command Functional Specifications 8.4.5 CF_SHARP Command Command “CF_SHARP_%1” [CR] “000-031”--------------- Directly specify setting value of Sharpness “UP”--------------------- Increment setting value of Sharpness by 1 “DN”--------------------- Decrement setting value of Sharpness by 1 Set user controlled value of Sharpness (Available only in the normal Power ON status) Details The value set by this command will not be stored in the projector’s memory.
PLC-WM5500/WM5500L Expand Serial Command Functional Specifications 8.4.8 CF_COLTEMP Command Command “CF_COLTEMP_%1” [CR] “000” ------------------------------ Xlow “001”------------------------------- Low “002”------------------------------- Mid “003”------------------------------- High Set Color Temperature The value set by this command will not be stored in the projector’s memory. Details Therefore, when the power is turned to ALL OFF status, the value returns to the original setting.
PLC-WM5500/WM5500L Expand Serial Command Functional Specifications 8.4.11 CF_PROGV Command Command “CF_PROGV_%1” [CR] “ON” ----------------- Set Progressive scan to On. “FILM” --------------- Set Progressive scan to Film. “OFF” ---------------- Set Progressive scan to OFF. “UP” ------------------ Switch setting forward direction (OFF→ON→FILM→OFF) “DN”...
PLC-WM5500/WM5500L Expand Serial Command Functional Specifications 8.4.13 CF_IMAGEADJ Command Command “CF_IMAGEADJ_%1”[CR] “RST”------ Reset adjusted value for the Image “STR1”---- Store current adjusted value to Image 1 “STR2”---- Store current adjusted value to Image 2 “STR3”---- Store current adjusted value to Image 3 “STR4”---- Store current adjusted value to Image 4 “STR5”---- Store current adjusted value to Image 5 “STR6”---- Store current adjusted value to Image 6...
PLC-WM5500/WM5500L Expand Serial Command Functional Specifications PC Adjust Control Command 8.5.1 CF_FSYNC Command Command “CF_FSYNC_%1” [CR] “0000-0031” ----------------- Directly specify setting value of Fine Sync “UP” --------------------------- Increment setting value of Fine Sync by 1 “DN” --------------------------- Decrement setting value of Fine Sync by 1 Set value of Fine Sync in PC signal (Available only in the normal Power ON status) Details...
PLC-WM5500/WM5500L Expand Serial Command Functional Specifications 8.5.4 CF_H-POS Command Command “CF_H-POS_%1” [CR] “0000-nnnn” -------- Directly specify setting value of Horizontal Position “nnnn” indicates maximum value, which is current value of (Total dots - Display area H) “UP” ------------------- Increment setting value of Horizontal Position by 1 “DN”...
PLC-WM5500/WM5500L Expand Serial Command Functional Specifications 8.5.7 CF_DLINE Command Command “CF_DLINE_%1” [CR] “0100-nnnn” ----------- Directly specify setting value of Display Line “nnnn” indicates maximum value, which is current value of (Total Line - Position V). “UP” ------------------- Increment setting value of Display Line by 1 “DN”...
PLC-WM5500/WM5500L Expand Serial Command Functional Specifications 8.5.11 CF_PCMODEFREE Command Command “CF_PCMODEFREE_%1” [CR] “1” --------------------------- Set Mode1 to Free status “2” --------------------------- Set Mode2 to Free status “3” --------------------------- Set Mode3 to Free status “4” --------------------------- Set Mode4 to Free status “5”...
PLC-WM5500/WM5500L Expand Serial Command Functional Specifications 8.6.3 CF_INPUT 1 Command Command “CF_INPUT1_%1” [CR] “ANALOG” ------------------------- Select PC Analog Input “SCART” --------------------------- Select SCART Input “HDMI” ---------------------------- Select HDMI Input Select Input 1 as well as Source specified in %1 (Available only in the normal Details Power ON status) Acceptable...
PLC-WM5500/WM5500L Expand Serial Command Functional Specifications 8.7.7 CF_KEYSTONE Command Command “CF_KEYSTONE _%1” [CR] “UP” ------------- Correct Keystone distortion to reduce upper part of image “FUP” ----------- Correct Keystone distortion to reduce upper part by 2 steps “DN” ------------- Correct Keystone distortion to reduce lower part of image “FDN”...
PLC-WM5500/WM5500L Expand Serial Command Functional Specifications 8.7.10 CF_CORNER-UR Command Command “CF_CORNER-UR_%1”[CR] “UP” ------------ Correct the horizontal line of image upwards “DN” ------------ Correct the horizontal line of image downwards “LEFT” --------- Correct the vertical line of image to the left “RIGHT”...
PLC-WM5500/WM5500L Expand Serial Command Functional Specifications 8.7.13 CF_CORNERTESTPAT Command Command “CF_CORNERTESTPAT_%1”[CR] “RED” ------------Select Red “WHITE” -------- Select White “BLUE” ---------- Select Blue “OFF” ------------ Select Off Display test patterns for Corner correction. (Available in normal Power ON status only) Details The value set by this command is stored in EEPROM and its setting is effective even after ALL is OFF.
PLC-WM5500/WM5500L Expand Serial Command Functional Specifications Lamp Command 8.8.1 CF_LAMPMODE Command Command “CF_LAMPMODE_%1” [CR] “NORMAL” ------------------------ Set Lamp status to Normal mode “ECO1” ------------------------------- Set Lamp status to Eco1 mode “ECO2” ------------------------------- Set Lamp status to Eco2 mode “AUTO” ----------------------------- Set Lamp status to Auto mode Select Lamp mode (Available only in the normal Power ON status) Details The value set by this command is stored in EEPROM and the setting remains...
PLC-WM5500/WM5500L Expand Serial Command Functional Specifications Sound Command 8.9.1 CF_VOLUME Command Command “CF_VOLUME_%1” [CR] “000-063” --------------------------- Directly specify value of Volume. “UP” --------------------------------- Increment setting value of Volume by 1 “DN” --------------------------------- Decrement setting value of Volume by 1 Control level of Volume (Available only in the normal Power ON status) Set Volume Up/Down the same way as RC and also directly specify value of Volume.
PLC-WM5500/WM5500L Expand Serial Command Functional Specifications 8.10.4 CF_DISP Command Command “CF_DISP_%1” [CR] “ON” ----------------------------- Set Display to On “CNTDWNOFF” --------------- Set Display to Count down Off “OFF” --------------------------- Set Display to Off “UP” --------------- Switch forward (On → Count down Off → Off → On → ---) “DN”...
PLC-WM5500/WM5500L Expand Serial Command Functional Specifications 8.10.12 CF_PIPPOSITION Command Command “CF_PIPPOSITION_%1” [CR] “POS1” -------------------- Move main picture position to up “POS2” -------------------- Move main picture position to down “POS3” -------------------- Move main picture position to left “POS4” -------------------- Move main picture position to right “POS5”...
PLC-WM5500/WM5500L Expand Serial Command Functional Specifications 8.10.15 CF_PIPMODEFREE Command Command “CF_PIPMODEFREE_%1” [CR] “USER1” --------------------------- Set User1 to Free status “USER 2” -------------------------- Set User2 to Free status “USER 3” -------------------------- Set User3 to Free status “USER 4” -------------------------- Set User4 to Free status “USER 5”...
PLC-WM5500/WM5500L Expand Serial Command Functional Specifications 8.10.24 CF_SIMPLEMODE Command Command “CF_SIMPLEMODE_%1” [CR] “ON” ------------------------------ Set Simple mode to ON “OFF” ------------------------------ Set Simple mode to OFF Set Simple mode.(Available only in the normal Power ON status) Details The status set by this command is stored in EEPROM and setting remains effective even after the power is turned to ALL OFF status.
PLC-WM5500/WM5500L Expand Serial Command Functional Specifications 8.10.27 CF_P-MANE Command Command “CF_P-MANE_%1” [CR] “OFF” ---------------------------------- Set Power Management to Off “READY” ----------------------------- Set Power Management to Ready “SHUTDOWN” --------------------- Set Power Management to Shut Down mode “UP” ----------------------- Switch forward (Off→Ready→Shut down→Off) “DN”...
PLC-WM5500/WM5500L Expand Serial Command Functional Specifications 8.10.31 CF_POINTER Command Command “CF_POINTER_%1” [CR] “ARROW” ---------------------- Select Arrow Pointer “FINGER” ---------------------- Select Finger Pointer “LASER” ---------------------- Select Dot Pointer Select indication of Pointer. (Available only in the normal Power ON status) Details The status set by this command is stored in EEPROM and setting value remains effective even after the power is turned to ALL OFF status.
PLC-WM5500/WM5500L Expand Serial Command Functional Specifications 8.10.35 CF_KEYDIS Command Command “CF_KEYDIS_%1” [CR] “NONE” ----------------------- RC and KEY are both enabled. “RC” ---------------------------- RC is disabled. “KEY” -------------------------- KEY is disabled. Disable RC and/or KEY functions Details (Available only in the normal Power ON status) Acceptable “000”...
PLC-WM5500/WM5500L Expand Serial Command Functional Specifications 8.10.39 CF_SHUTH Command Command “CF_SHUTH_%1” [CR] “005”-“480”----------Specify setting time directly “UP” ------------------ Add 1 minute “DN” ------------------Decrease 1 minute Set time of operating shutter management function. (Valid only when in the normal Power ON status) Details The status set by this command is stored in EEPROM and setting remains effective even after the power is turned to ALL OFF status.
PLC-WM5500/WM5500L Expand Serial Command Functional Specifications 8.10.42 CF_DELAYCTRL Command Command “CF_DELAYCTRL_%1” [CR] “OFF”---------- Set Video delay control to OFF “LOW”---------- Set Video delay control to LOW “MID”---------- Set Video delay control to MID “HIGH”---------- Set Video delay control to HIGH Select the mode of Video delay control (Valid only when in the normal Power ON status) Details...
PLC-WM5500/WM5500L Expand Serial Command Functional Specifications 8.11.3 CF_POWER Command Command “CF_POWER_%1” [CR] “ON” ----------------------------- Power ON “OFF” --------------------------- Power OFF * Issuing another command during countdown process forced countdown operation to be terminated. * Error Code is returned in some projector statuses, which indicates the command is impossible to be executed.
PLC-WM5500/WM5500L Expand Serial Command Functional Specifications Status Read Command 9.1 Format PC issues commands in format as below: “CR_ COMMAND” [CR] Command: String When projector receives the appropriate command, it returns the required data as a string. “000_” %1 [CR] %1: Required Data (String) When the received data cannot be decoded, the projector returns “?”...
PLC-WM5500/WM5500L Expand Serial Command Functional Specifications 9.4.4 CR_TINT Command Command “CR_TINT” [CR] Details Get user controlled value of Tint Acceptable “000_%1” [CR] “000 – 063” Response “Error Code” [CR] --- When command is not available in the given Unacceptable condition (such as being selected input). “?”...
PLC-WM5500/WM5500L Expand Serial Command Functional Specifications 9.4.9 CR_WBAL-B Command Command “CR_WBAL-B” [CR] Details Get user controlled Blue value of White Balance Acceptable “000_%1” [CR] Response “000 – 063” Unacceptable “Error Code” [CR] 9.4.10 CR_COLTEMP Command Command “CR_COLTEMP” [CR] Details Get Color Temperature setting status Acceptable “000_%1”...
PLC-WM5500/WM5500L Expand Serial Command Functional Specifications 9.5 PC Adjust Status Read Command 9.5.1 CR_FSYNC Command Command “CR_FSYNC” [CR] Details Get value of Fine Sync Acceptable “000_%1” [CR] “0000 – 0031” Response “Error Code” [CR] --- When command is not available in the given Unacceptable condition (such as being selected input) “?”...
PLC-WM5500/WM5500L Expand Serial Command Functional Specifications 9.5.5 CR_V-POS Command Command “CR_V-POS” [CR] Details Get value of Vertical Position Acceptable “000_%1” [CR] “0000 – nnnn” (nnnn = Total Line – Display area V) Response “Error Code” [CR] ------ When command is not available in the Unacceptable given condition (such as being selected input “?”...
PLC-WM5500/WM5500L Expand Serial Command Functional Specifications 9.5.8 CR_ORGMODE Command Command “CR_ORGMODE” [CR] Get the original signal of current selected Mode that is set in PC Adj. Details When MODE1- 10 or EXT11-50 is not selected, get the current signal. Acceptable “000_%1”...
PLC-WM5500/WM5500L Expand Serial Command Functional Specifications 9.5.9 CR_PCSTORE Command Command “CR_PCSTORE” [CR] Get Free or Stored status of MODE1 - 10 in PC Adjust. Details Data consists of 10 bytes and each byte represents MODE1-10. (F:Free, S:Stored) Acceptable “000_%1” [CR] “FFFFFFFFFF”...
PLC-WM5500/WM5500L Expand Serial Command Functional Specifications 9.6 Video Status Read Command 9.6.1 CR_SERSYS Command Command “CR_SERSYS” [CR] Get selected current signal. Auto detected signal is returned in Auto mode Details Only available when Input is Y,Pb/Cb,Pr/Cr, S-Video or Video. (This is not the case for PC-Analog and HDMI signals) Acceptable “000_%1”...
PLC-WM5500/WM5500L Expand Serial Command Functional Specifications 9.7.8 CR_SYSLIST Command Command “CR_SYSLIST” [CR] Details Get possible systems for System list Acceptable “000_%1_%2_---_%x” [CR] Error Code “101” is returned for no signal. Otherwise following values are returned according to Source. When input is PC-Analog; “XGA1”...
PLC-WM5500/WM5500L Expand Serial Command Functional Specifications 9.7.10 CR_HMSLOT Command Command “CR_HMSLOT” [CR] Details Get the total number of Input. Acceptable “000_%1” [CR] “004” ------------ When PJ-Net is attached. Response “003” ------------ When PJ-Net is not attached. Unacceptable “Error Code” [CR] 9.7.11 CR_NMSLOT1 Command Command “CR_NMSLOT1”...
PLC-WM5500/WM5500L Expand Serial Command Functional Specifications 9.7.15 CR_IDSLOT1 Command Command “CR_IDSLOT1” [CR] Get ID information of Input1. This command is to determine sources possible to Details input. Acceptable “000_%1” [CR] “30” --------------- On-board (HDMI and D-Sub) Response Available source: ANALOG, SCART, HDMI Unacceptable “Error Code”...
PLC-WM5500/WM5500L Expand Serial Command Functional Specifications 9.8.6 CR_ KYSTNMODE Command Command “CR_KYSTNMODE” [CR] Details Get setting status of Keystone Store Mode Acceptable “000_%1” [CR] “STR” ---------------------- Store mode is “Store” Response “RST” ---------------------- Store mode is “Reset” Unacceptable “?” [CR] -------------------- When unknown command is received 9.8.7 CR_CORNERTESTPAT Command Command...
PLC-WM5500/WM5500L Expand Serial Command Functional Specifications 9.9 Lamp Status Read Command 9.9.1 CR_LAMPREPL Command Command “CR_LAMPREPL” [CR] Details Get information of Lamp Replacement time Acceptable “000_%1” [CR] “1Y” ----------------- indicates over lamp replacement time Response “1N” ----------------- indicates under lamp replacement time Unacceptable “?”...
PLC-WM5500/WM5500L Expand Serial Command Functional Specifications 9.9.6 CR_PROJH Command Command “CR_PROJH” [CR] Details Get total running time of Projector (in hours) Acceptable “000_%1” [CR] Response “0000000 – 0099999” Unacceptable “Error Code” [CR] 9.9.7 CR_HMLAMP Command Command “CR_HMLAMP” [CR] Details Get total lamp number Acceptable “000_%1”...
PLC-WM5500/WM5500L Expand Serial Command Functional Specifications 9.10 Sound Status Read Command 9.10.1 CR_VOLUME Command Command “CR_VOLUME” [CR] Get volume value by user control Details * When input signal is Network, error code “101” is returned. Acceptable “000_%1” [CR] Response “000 – 063” Unacceptable “Error Code”...
PLC-WM5500/WM5500L Expand Serial Command Functional Specifications 9.11 Setting Status Read Command 9.11.1 CR_LANG Command Command “CR_LANG” [CR] Details Get selected language Acceptable “000_%1” [CR] “ENG” -------------------------- English is selected “DEU” -------------------------- German is selected “FRA” -------------------------- French is selected “ITA” --------------------------- Italian is selected “ESP”...
PLC-WM5500/WM5500L Expand Serial Command Functional Specifications 9.11.5 CR_LOGO Command Command “CR_LOGO” [CR] Details Get setting status of Logo Acceptable “000_%1” [CR] “DFLT” ----------------------------- Default Logo is enabled Response “USER” --------------------------- User is enabled “OFF” ------------------------------ Logo is disabled Unacceptable “Error Code” [CR] 9.11.6 CR_LOGOLOCK Command Command “CR_LOGOLOCK”...
PLC-WM5500/WM5500L Expand Serial Command Functional Specifications 9.11.9 CR_PIPMAININP Command Command “CR_PIPMAININP” [CR] Details Get Input and Source for “Picture in Picture”. (Main picture) Acceptable “000_%1_%2” [CR] “1” -------------------- Input1 is selected “2” -------------------- Input2 is selected “3” -------------------- Input3 is selected “ANALOG --------------------- ANALOG RGB is selected Response “VIDEO”...
PLC-WM5500/WM5500L Expand Serial Command Functional Specifications 9.11.12 CR_PIPFRAMELOCK Command Command “CR_PIPFRAMELOCK” [CR] Details Get setting status of Frame lock in “Picture in Picture”. Acceptable “000_%1” [CR] “MAIN” -------------------- Main picture is selected Response “SUB” --------------------- Sub picture is selected Unacceptable “Error Code”...
PLC-WM5500/WM5500L Expand Serial Command Functional Specifications 9.11.26 CR_P-MANE Command Command “CR_P-MANE” [CR] Details Get setting status of Power management Acceptable “000_%1” [CR] “OFF” ------------------------ Power Management is disabled “READY” -------------------- Power Management is set to Ready Response “SHUTDOWN” ------------ Power Management is set to Shut Down mode Unacceptable “Error Code”...
PLC-WM5500/WM5500L Expand Serial Command Functional Specifications 9.11.31 CR_PTIMEMODE Command Command “CR_PTIMEMODE” [CR] Details Get setting status of count up/down mode in P-timer Acceptable “000_%a” [CR] “COUNTUP” -------------------- Set P-timer to Count up mode Response “COUNTDN” -------------------- Set P-timer to Count down mode Unacceptable “Error Code”...
PLC-WM5500/WM5500L Expand Serial Command Functional Specifications 9.11.36 CR_PJLOCKNOW Command Command “CR_PJLOCKNOW” [CR] Details Get actual setting status of PIN code lock Acceptable “000_%1” [CR] “LOCK” ------ PJ is locked PIN code lock is set to ON1/ON2 on the menu and PJ PIN code is not entered, therefore PJ is actually locked.
PLC-WM5500/WM5500L Expand Serial Command Functional Specifications 9.11.44 CR_TESTPAT Command Command “CR_TESTPAT” [CR] Details Get setting status of Test pattern Acceptable “000_%1” [CR] “COLOR” ---------------------- Color bar is displayed “GRAD1” ---------------------- 16step(white→black) is displayed “GRAD2” ---------------------- 16step(white←black) is displayed “GRAD3” ---------------------- 16step(white↓black) is displayed Response “GRAD4”...
PLC-WM5500/WM5500L Expand Serial Command Functional Specifications 9.12 Other Status Read Commands 9.12.1 CR_STATUS Command COMMAND “CR_STATUS” [CR] Get operating status of Projector Detail Same as “CR0” in basic command except error code follows it. Acceptable “000_%1” [CR] “00” = Power ON “80”...
PLC-WM5500/WM5500L Expand Serial Command Functional Specifications 9.12.5 CR_TEMPFAIL Command Command “CR_TEMPFAIL” [CR] Get the temperature inside a projector when abnormal temperature status Details occurs. It is possible to get the temperatures all at once when several sensors installed. Acceptable “000_%1_%2_%3” [CR] %1 ------------------ Sensor 1 temp.
PLC-WM5500/WM5500L Expand Serial Command Functional Specifications 9.12.6 CR_TEMP Command Command “CR_TEMP” [CR] Get the current temperature information inside a projector. Details It is possible to get the temperatures all at once when several sensors installed. Acceptable “000_%1_%2_%3” [CR] %1 ------------------ Sensor 1 temp. (External temp.) %2 ------------------ Sensor 2 temp.