CHAPTER 1 GENERAL ADJUSTMENTS SAFETY INSTRUCTIONS WARNING: BEFORE SERVICING THIS CHASSIS, READ THE “X-RAY RADIATION PRECAUTION”, “SAFETY PRECAU- TION” AND “PRODUCT SAFETY NOTICE” INSTRUCTIONS BELOW. X-RAY RADIATION PRECAUTION 1. Excessive high voltage can produce potentially hazard- 2. The only source of X-RAY RADIATION in this TV receiver ous X-RAY RADIATION.
WARNING: BEFORE SERVICING THIS CHASSIS, READ THE “X-RAY RADIATION PRECAUTION”, “SAFETY PRECAU- TION” AND “PRODUCT SAFETY NOTICE” ON PAGE 3 OF THIS MANUAL. SET-UP ADJUSTMENT The following adjustments should be made when a complete realignment is required or a new picture tube is installed. Perform the adjustments in order as follows : 1.
Page 5
CONVERGENCE ADJUSTMENTS CIRCUMFERENCE CONVERGENCE ADJUSTMENT NOTE: Before attempting any convergence adjustments, the 1. Loosen the clamping screw of deflection yoke slightly to receiver should be operated for at least fifteen min- allow the yoke to tilt. utes. 2. Temporarily put a wedge as shown in figure 1. (Do not remove cover paper on adhesive part of the wedge.) CENTER CONVERGENCE ADJUSTMENT 3.
SERVICE MODE 1. ENTERING TO SERVICE MODE 1) Press o button once on 2) Press o button again to 3) While pressing the o button, Remote Control. keep pressing. press MENU button on TV set. Item Data (Service mode display) 2.
Page 7
4. SELECTING THE ADJUSTING ITEMS 1) Every pressing of CHANNEL s button in the service mode changes the adjustment items in the order of table-2. (t button for reverse order) Refer to table-2 for preset data of adjustment mode. (See SETTING & ADJUSTING DATA on page 13) 5.
Page 8
8. SELF DIAGNOSTIC FUNCTION 1) Press “9” button on Remote Control during display of adjustment menu in the service mode. The diagnosis will begin to check if interface among IC’s are executed properly. 2) During diagnosis, the following displays are shown. Indicated color of mode now selected : Green and Red Indicated color of other modes : White...
DESIGN MODE 1. ENTERING TO DESIGN MODE 1) Select the Service mode. 2) While pressing (or CALL) button on 3) Press MENU button on TV. Remote and press MENU button on TV. ITEM Press DATA Press (Design mode) (Adjustment mode) When QA02 is initialized, items “OPT0”...
ELECTRICAL ADJUSTMENTS ITEM ADJUSTMENT PROCEDURE FOCUS VR ADJ 1. Enter the service mode, then select any register item. 2. Press the TV/VIDEO button on the Remote until the black cross-bar pattern ap- pears on the screen. 3. Adjust the FOCUS control (on T461) for well defined scanning lines on the picture screen.
Page 11
ITEM ADJUSTMENT PROCEDURE WHITE BALANCE 1. Set Contrast to 40, and brightness to +20 by picture control. ADJUSTMENT 2. Set the TV in service mode, and get the inside W/B adjusting signal with VIDEO button. • CUTOFF ADJUSTMENT 3. Select RCUT, GCUT and BCUT with CHANNEL s, t buttons, to set individual (RCUT) values to Initial reference data, and to set GDRV and BDRV to Initial reference (GCUT)
CIRCUIT CHECK HIGH VOLTAGE CHECK CAUTION: There is no HIGH VOLTAGE ADJUSTMENT on this chassis. Checking should be done following the steps below. 1. Connect an accurate high voltage meter to the second anode of the picture tube. 2. Turn on the receiver. Set the BRIGHTNESS and CONTRAST controls to minimum (zero beam current). 3.
CHAPTER 2 SPECIFIC INFORMATIONS SETTING & ADJUSTING DATA SAFETY INSTRUCTIONS 25" HIGH VOLTAGE AT ZERO BEAM: 32.8 kV MAX HIGH VOLTAGE: 33.0 kV AC VOLTAGE 110~240 V Table-1 SERVICE MODE ADJUSTING ITEMS AND DATAS IN THE SERVICE MODE: Item Adjustment Reference data Data ←...
LOCATION OF CONTROLS Front r ON-TIMER (green) q Power indicator (red) a Input source selection Remote sensor q Power switch Bihind the door L/MONO VIDEO AUDIO MENU c* Channel Position ts MENU a(3)Video 3 input Menu item select terminals Headphone jack (ø3.5 mm) For private listening, connect headphones.
Page 15
Remote CALL CALL Power on/standby o Sound Mute + – Volume Number (0-9) Channel position –/-- –/- - 1 or 2 digit selection a Input source selection* MENU MENU* h Picture menu 8 Sound menu 89 Menu item select* – + Menu item adjust* m I/II Stereo/Bilingual Selection * These functions have duplicate...
PROGRAMMING CHANNEL MEMORY • First, use the ASM (Automatic Search Memory) function to preset all the active channels in your area automatically. Then, arrange the preset channels with the SEARCH (>>>), MFT (Manual Fine Tuning) and AFT (Auto Fine Tuning) functions so that you can tune into only desired channels. •...
Page 17
• Use the SEARCH function if desired channels could not be preset with the ASM, or if you would like to preset the desired channels to specific position numbers one by one. • The adjustments below are not necessary under normal conditions. However, in areas of inferior broadcast conditions where adjustment is necessary for a better picutre, adjust the tuning with the MFT (Manual Fine Tuning).
• The part number must be used when ordering parts, in order to assist in processing, be sure to include the Model number and Description. • The PC board assembly with mark is no longer available after the end of the production. Model : 25AF6SH Capacitors ..... CD Ceramic Disk : Plastic Film : Electrolytic Resistors ....
Page 20
Location Location Location Location Location Location Location Location Location Location Parts No. Parts No. Parts No. Parts No. Parts No. Description Description Description Description Description Parts No. Parts No. Parts No. Parts No. Parts No. Description Description Description Description Description C503 24092398 CERAMIC DISC, 25V 0.1UF Z, 24092398A...
Page 21
Location Location Location Location Location Location Location Location Location Location Parts No. Parts No. Parts No. Parts No. Parts No. Description Description Description Description Description Parts No. Parts No. Parts No. Parts No. Parts No. Description Description Description Description Description CV30 24073077 ELECTROLYTIC, 50V 0.1UF M 3A...
Page 22
Location Location Location Location Location Location Location Location Location Location Parts No. Parts No. Parts No. Parts No. Parts No. Description Description Description Description Description Parts No. Parts No. Parts No. Parts No. Parts No. Description Description Description Description Description R492 24366472 CARBON FILM, 1/6W 4.7K OHM J...
Page 23
Location Location Location Location Location Location Location Location Location Location Parts No. Parts No. Parts No. Parts No. Parts No. Description Description Description Description Description Parts No. Parts No. Parts No. Parts No. Parts No. Description Description Description Description Description RA04 24366102 CARBON FILM, 1/6W 1K OHM J...
Page 24
Location Location Location Location Location Location Location Location Location Location Parts No. Parts No. Parts No. Parts No. Parts No. Description Description Description Description Description Parts No. Parts No. Parts No. Parts No. Parts No. Description Description Description Description Description COILS &...
Page 25
Location Location Location Location Location Location Location Location Location Location Parts No. Parts No. Parts No. Parts No. Parts No. Description Description Description Description Description Parts No. Parts No. Parts No. Parts No. Parts No. Description Description Description Description Description QA11 23205081 TRANSISTOR, 2SA1980-Y(BU...
Page 33
SCHEMATIC DIAGRAM MODEL : 25AF6SH WARNING: BEFORE SERVICING THIS CHASSIS, READ THE "X-RAY RADIATION PRECAUTION", "SAFETY PRECAUTION" AND "PRODUCT SAFETY NOTICE" ON THE MANUAL FOR THIS MODEL. CAUTION: The international hazard symbols "*" in the schematic diagram and the parts list designate components which have special characteristics important for safety and should be replaced only with types identical to those in the original circuit or specified in the parts list.
SPECIFICATIONS Rated voltage g 110 V – 240 V, 50/60 Hz Power consumption 125 W (Approx.) (at g 220 V, 50 Hz) 582 mm × 466 mm × 531 mm Dimensions Mass 33.7 kg Picture tube TYPE 25, flat picture tube 63 cm dia.
Page 36
SCHEMATIC DIAGRAM MODEL : 25AF6SH WARNING: BEFORE SERVICING THIS CHASSIS, READ THE "X-RAY RADIATION PRECAUTION", "SAFETY PRECAUTION" AND "PRODUCT SAFETY NOTICE" ON THE MANUAL FOR THIS MODEL. CAUTION: The international hazard symbols "*" in the schematic diagram and the parts list designate components which have special characteristics important for safety and should be replaced only with types identical to those in the original circuit or specified in the parts list.