Page 1
http://www.lgservice.com Air Conditioner OWNER'S MANUAL Type : Wall Mounted IMPORTANT • Please read this owner's manual carefully and thoroughly before installing and operating your room air conditioner. • Please retain this owner's manual for future reference after reading it thoroughly.
Air Conditioner Owner’s Manual TABLE OF CONTENTS FOR YOUR RECORDS A. Safety Precautions ......3 B. Electrical Safety........6 Write the model and serial numbers here: Temporary Use of an Adapter ....6 Model # Temporary Use of an Extension Cord ...6 Serial # Symbols used in this Manual....6 You can find them on a label on the side of each unit.
Safety Precautions Safety Precautions To prevent injury to the user or other people and property damage, the following instructions must be followed. I Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications. This symbol indicates the possibility of death or serious injury.
Page 4
Safety Precautions Indoor/outdoor wiring connections must Safely dispose off the packing materials. Make sure to check that the power cable be secured tightly and the cable should Like screws, nails, batteries, broken plug is not dirty, loose or broken and be routed properly so that there is no things etc after installation or svc and then only insert the plug completely.
Page 5
Safety Precautions Do not use the product for special purposes, Do not block the inlet or outlet of air flow. Use a soft cloth to clean. Do not use such as preserving foods, works of art, etc. It harsh detergents, solvents or splashing is a consumer air conditioner, not a precision water etc .
Electrical Safety Electrical Safety • This appliance must be properly grounded. To minimize the risk of electric shock, you must always plug into a grounded oulet. • Do not cut or remove the grounding prong from the power plug. • Attaching the adapter ground terminal to the wall receptacle cover screw does not ground the appliance unless the cover screw is metal and not insulated, and the wall receptacle is grounded through the house wiring.
Product Introduction Product Introduction Here is a brief introduction of the indoor and outdoor units. Indoor Units Premium type Rational type Air inlet Allergy free filter Plasma filter + Triple filter Plasma filter Air filter Front gr ON/OFF button Air inlet Air filter Front grille Signal receiver...
Operating Instructions Operating Instructions How to insert the Batteries 1. Remove the battery cover by pulling it according to the arrow direction. 2. Insert new batteries making sure that the (+) and (-) of battery are installed correctly. 3. Reattach the cover by sliding it back into position. NOTE 1.
Operating Instructions Wireless Remote Controller The controls will look like the following. ON/OFF BUTTON Used to turn off/on the unit. Signal transmitter OPERATION MODE SELECTION BUTTON Used to select the operation mode. ROOM TEMPERATURE SETTING BUTTONS Used to select the room temperature. INDOOR FAN SPEED SELECTION BUTTON Used to select fan speed in six steps low, medium-low, medium, medium-high, high and natural wind.
Page 10
Operating Instructions The controls will look like the following. Signal transmitter Premium type : - Optional1 ECO EYE BUTTON Used to set and to cancel the timer operation. - Optional2 JET COOL / MOISTURE COOLING BUTTON Used to start or stop the speed cooling and Moisture Cooling.
Operating Instructions Operation Mode ON/OFF Press the ON/OFF BUTTON to turn the unit on. The unit will respond with a beep. Open the cover of the remote controller and press the operation mode button. Each time MODE the button is pressed, the operation mode is shifted in the direction of the arrow. Auto Healthy Heating...
Operating Instructions Auto Changeover Operation (Optional) This operation is basically heating or cooling function of the air MODE conditioner. But during this operation the controller changes the operation mode automatically to keep the temperature within ±2°C with respect to the setting temperature. Auto Operation(Optional) <For Cooling Model>...
During this operation, 'Cooling' lamp lights up. PLASMA Purification Operation(Optional) Plasma filter is a technology developed by LG to get rid of microscopic contaminants in the intake air by generating a plasma of high charge electrons. This plasma kills and destroys the contaminants completely to provide clean and hygienic air.
Operating Instructions Energy-Saving Cooling Mode (Optional) Energy-saving cooling mode can save energy in cooling operation, because it can operate efficiently by setting body-adaptation time according to the change of time and temperature and adjusting desired temperature automatically. 1. Press the ON/OFF BUTTON to start the unit. 2.
Operating Instructions Timer Setting Button on the Description Indication on the LCD Display Remote Controller Press the Timer button once to set on the Reserved 'On' (Press the Timer button twice to set the Reserved 'Off') Press the Time Setting buttons until the desired time is set.
Operating Instructions Horizontal Vane Control The Horizontal Vane can be adjusted by using the remote controller. 1. Press the ON/OFF BUTTON to start the unit. 2. Press the vertical airflow direction button. Each time the button is pressed, the air-flow direction is changed in the direction of the arrow.
Operating Instructions Jet Cool/Heat Operation Jet cool function can be used to cool the room quickly in hot summer. When this function is turned on, the air conditioner runs in cooling operation mode with super high fan speed and 18°C setting temperature for 30 minutes for fast and effective cooling.
Operating Instructions Eco Eye Operation (Optional) Eco Eye operation controls airflow by sensing the position of ECO EYE residents. Each time the button is pressed, the mode is shifted in the direction of the arrow. Direct airflow Indirect airflow Cancellation NOTE •...
Page 19
Operating Instructions Detecting Range Direct Airflow Indirect Airflow Undetectable zone(1.2m) Maximum 5m of detection is possible on 2.3m height of installation standard (when people are seated). According to installation height, there Energy Saving mode is a possibility the detecting range change.
Operating Instructions Forced operation Forced operation is used when the remote controller can't be used. The operation will be started if the ON/OFF button is pressed. If you want to stop the operation, re-press the button. Premium type Rational type ON/OFF ON/OFF button...
Maintenance and Service Maintenance and Service Before performing any maintenance, turn off the main power to the system, disconnect the circuit breaker and unplug the power cord. Indoor Unit Clean the unit with a soft dry cloth. Do not use bleach or abrasives. Never use any of these •...
Page 22
Maintenance and Service Removal of Filters Open the front panel as shown. Then pull the filter tab slightly forward to remove the air filter. After removing the air filter remove the plasma and Allergy Free Filter by slightly pulling downwards. Allergy filter Plasma filter...
Maintenance and Service Outdoor Unit The heat exchanger coils and panel vents of the outdoor unit should be checked regularly. If clogged with dirt or soot, the heat exchanger and panel vents may be professionally steam cleaned. NOTE Dirty or clogged coils will reduce the operating efficiency of the system and cause higher operating costs. Operation Tips! Do not overcool the room.
Maintenance and Service Troubleshooting Tips! Save time and money! The air conditioner may be operating abnormally when: Problem Possible Causes What To Do I The air conditioner is • Make sure the air conditioner plug is unplugged. pushed completely into the outlet. I The fuse is blown/circuit •...