  • Page 1 ® Relion 615 series Motor Protection and Control REM615 ANSI DNP3 Point List Manual...
  • Page 3 Document ID: 1MAC254287-MB Issued: 01/20/2010 Revision: A Product version: 2.0 © Copyright 2010 ABB. All rights reserved...
  • Page 4 Copyright This document and parts thereof must not be reproduced or copied without written permission from ABB, and the contents thereof must not be imparted to a third party, nor used for any unauthorized purpose. The software or hardware described in this document is furnished under a license and may be used, copied, or disclosed only in accordance with the terms of such license.
  • Page 5 In case any errors are detected, the reader is kindly requested to notify the manufacturer. Other than under explicit contractual commitments, in no event shall ABB be responsible or liable for any loss or damage resulting from the use of this manual or the application of the equipment.
  • Page 6 (EMC Directive 2004/108/EC) and concerning electrical equipment for use within specified voltage limits (Low-voltage directive 2006/95/EC). This conformity is the result of tests conducted by ABB in accordance with the product standards EN 50263 and EN 60255-26 for the EMC directive, and with the product standards EN 60255-6 and EN 60255-27 for the low voltage directive.
  • Page 7: Table Of Contents

    Table of contents Table of contents Section 1 Introduction................3 This manual....................3 Intended audience..................3 Product documentation................4 Product documentation set..............4 Document revision history..............5 Related documentation................6 Symbols and conventions.................6 Safety indication symbols..............6 Manual conventions................6 Functions, codes and symbols............7 Section 2 DNP3 data mappings............9 Overview....................9 Point list for REM615 Ver.
  • Page 9: Section 1 Introduction

    Section 1 1MAC254287-MB A Introduction Section 1 Introduction This manual The point list manual describes the outlook and properties of the data points specific to the IED. The manual should be used in conjunction with the corresponding communication protocol manual. Intended audience This manual addresses the communication system engineer or system integrator responsible for pre-engineering and engineering for communication setup in a...
  • Page 10: Product Documentation

    Section 1 1MAC254287-MB A Introduction Product documentation 1.3.1 Product documentation set Engineering manual Engineering manual Engineering manual Installation manual Installation manual Installation manual Commissioning manual Commissioning manual Commissioning manual Operation manual Operation manual Operation manual Service manual Service manual Service manual Application manual Application manual Application manual...
  • Page 11: Document Revision History

    Some of the manuals are not available yet. 1.3.2 Document revision history Document revision/date Product series version History A/01/20/2010 First release Download the latest documents from the ABB web site http:// www.abb.com/substationautomation. REM615 ANSI Point List Manual...
  • Page 12: Related Documentation

    Section 1 1MAC254287-MB A Introduction 1.3.3 Related documentation Name of the document Document ID DNP3 Communication Protocol Manual 1MAC052460-MB Symbols and conventions 1.4.1 Safety indication symbols The caution icon indicates important information or warning related to the concept discussed in the text. It might indicate the presence of a hazard which could result in corruption of software or damage to equipment or property.
  • Page 13: Functions, Codes And Symbols

    Section 1 1MAC254287-MB A Introduction To save the changes in non-volatile memory, select Yes and press • Parameter names are shown in italics, for example: The function can be enabled and disabled with the Operation setting. • Parameter values are indicated with quotation marks, for example: The corresponding parameter values are "Enabled"...
  • Page 14 Section 1 1MAC254287-MB A Introduction Function IEC 61850 IEC 60617 ANSI Control Circuit breaker control CBXCBR1 I<->O CB 52-1 Emergency start function ESMGAPC1 ESTART 62EST Supervision and Monitoring Circuit breaker condition monitoring SSCBR1 CBCM 52CM Trip circuit monitoring 1 TCSSCBR1 TCS(1) TCM-1 Trip circuit monitoring 2...
  • Page 15: Section 2 Dnp3 Data Mappings

    Section 2 1MAC254287-MB A DNP3 data mappings Section 2 DNP3 data mappings Overview This document describes the DNP3 data points and structures available in REM615 Ver. 2.0 ANSI. The point tables show all the available DNP3 data points in this IED. The data objects in the point tables are listed in alphabetical order based on the objects' IEC61850 names.
  • Page 16 Section 2 1MAC254287-MB A DNP3 data mappings 61850 Path Default Default Disabled Description event Index Class LD0.LEDPTRC1.Str.phsB Global conditioning Start LD0.LEDPTRC1.Str.phsC Global conditioning Start LD0.TRPPTRC1.Tr.general TRPPTRC1 General trip output signal LD0.TRPPTRC1.Op.general TRPPTRC1 Operate input signal LD0.TRPPTRC2.Tr.general TRPPTRC2 General trip output signal LD0.TRPPTRC2.Op.general TRPPTRC2 Operate input signal LD0.SSCBR1.InSprChStr.stVal...
  • Page 17 Section 2 1MAC254287-MB A DNP3 data mappings 61850 Path Default Default Disabled Description event Index Class LD0.XGGIO130.Ind4.stVal X130 (BIO) X130-Input 4 LD0.XGGIO130.Ind5.stVal X130 (BIO) X130-Input 5 LD0.XGGIO130.Ind6.stVal X130 (BIO) X130-Input 6 LD0.XGGIO130.SPCSO1.stVal X130 (BIO) X130-Output 1 LD0.XGGIO130.SPCSO2.stVal X130 (BIO) X130-Output 2 LD0.XGGIO130.SPCSO3.stVal X130 (BIO) X130-Output 3 LD0.XAGGIO130.Ind1.stVal...
  • Page 18 Section 2 1MAC254287-MB A DNP3 data mappings 61850 Path Default Default Disabled Description event Index Class LD0.LEDGGIO1.SPCSO5.stVal Alarm LEDs LED 5 LD0.LEDGGIO1.SPCSO6.stVal Alarm LEDs LED 6 LD0.LEDGGIO1.SPCSO7.stVal Alarm LEDs LED 7 LD0.LEDGGIO1.SPCSO8.stVal Alarm LEDs LED 8 LD0.LEDGGIO1.SPCSO9.stVal Alarm LEDs LED 9 LD0.LEDGGIO1.SPCSO10.stVal Alarm LEDs LED 10 LD0.LEDGGIO1.SPCSO11.stVal...
  • Page 19 Section 2 1MAC254287-MB A DNP3 data mappings 61850 Path Default Default Disabled Description event Index Class LD0.PHLPTOC1.InEnaMult.stVal PHLPTOC1 Enable signal for current multiplier LD0.CCBRBRF1.Str.general CCBRBRF1 Start timer running LD0.CCBRBRF1.OpEx.general CCBRBRF1 Breaker failure trip (external trip) LD0.CCBRBRF1.OpIn.general CCBRBRF1 Operate retrip (internal trip) LD0.CCBRBRF1.InStr.stVal CCBRBRF1 CBFP start command LD0.CCBRBRF1.InPosCls.stVal...
  • Page 20 Section 2 1MAC254287-MB A DNP3 data mappings 61850 Path Default Default Disabled Description event Index Class LD0.ARCSARC21.FADet.stVal ARCSARC2 Fault arc detected LD0.ARCSARC21.InRemFA.stVal ARCSARC2 Remote Fault arc detected LD0.ARCPTRC21.Op.general ARCSARC2 Operate LD0.ARCSARC31.FADet.stVal ARCSARC3 Fault arc detected LD0.ARCSARC31.InRemFA.stVal ARCSARC3 Remote Fault arc detected LD0.ARCPTRC31.Op.general ARCSARC3 Operate LD0.TCSSCBR1.CirAlm.stVal...
  • Page 21 Section 2 1MAC254287-MB A DNP3 data mappings 61850 Path Default Default Disabled Description event Index Class LD0.MNSPTOC2.Op.general MNSPTOC2 Operate LD0.LOFLPTUC1.Str.general LOFLPTUC1 Start LD0.LOFLPTUC1.Op.general LOFLPTUC1 Operate CTRL.LLN0.Loc.stVal Local / Remote CTRL.LLN0.Loc1.stVal Local / Off CTRL.CBCILO1.EnaOpn.stVal CBXCBR1 ENA_OPEN CTRL.CBCILO1.EnaCls.stVal CBXCBR1 ENA_CLOSE CTRL.CBCILO1.ItlByPss.stVal CBXCBR1 ITL_BYPASS CTRL.CBCSWI1.Pos.stSeld CBXCBR1 Switch general...
  • Page 22 Section 2 1MAC254287-MB A DNP3 data mappings 61850 Path Default Default Disable Description Index Class LD0.XGGIO100.SPCSO6.Oper.ctlVal none X100-Output S04 LD0.LEDGGIO1.SPCSO1.Oper.ctlVal none LED 1 LD0.LEDGGIO1.SPCSO2.Oper.ctlVal none LED 2 LD0.LEDGGIO1.SPCSO3.Oper.ctlVal none LED 3 LD0.LEDGGIO1.SPCSO4.Oper.ctlVal none LED 4 LD0.LEDGGIO1.SPCSO5.Oper.ctlVal none LED 5 LD0.LEDGGIO1.SPCSO6.Oper.ctlVal none LED 6 LD0.LEDGGIO1.SPCSO7.Oper.ctlVal...
  • Page 23 Section 2 1MAC254287-MB A DNP3 data mappings 61850 Path Default Default Disabled Description Multiplier event Index Class LD0.SSCBR1.AccAPwrPhC.mag.f Accumulated currents power (Iyt) phase C LD0.CMMXU1.A.phsA.instCVal.ang. Phase currents LD0.CMMXU1.A.phsA.instCVal.mag Phase currents LD0.CMMXU1.A.phsA.cVal.mag.f Phase currents LD0.CMMXU1.A.phsB.instCVal.ang. Phase currents LD0.CMMXU1.A.phsB.instCVal.mag Phase currents LD0.CMMXU1.A.phsB.cVal.mag.f Phase currents LD0.CMMXU1.A.phsC.instCVal.ang.
  • Page 24 Section 2 1MAC254287-MB A DNP3 data mappings 61850 Path Default Default Disabled Description Multiplier event Index Class LD0.VMMXU1.PPV.phsAB.instCVal. ang.f Phase to phase voltages LD0.VMMXU1.PPV.phsAB.instCVal. mag.f Phase to phase voltages LD0.VMMXU1.PPV.phsAB.cVal.ma Phase to phase voltages LD0.VMMXU1.PPV.phsBC.instCVal. ang.f Phase to phase voltages LD0.VMMXU1.PPV.phsBC.instCVal.
  • Page 25 Section 2 1MAC254287-MB A DNP3 data mappings 61850 Path Default Default Disabled Description Multiplier event Index Class LD0.FLTMSTA1.MaxAmpsA.mag.f Maximum phase A current LD0.FLTMSTA1.MaxAmpsB.mag.f Maximum phase B current LD0.FLTMSTA1.MaxAmpsC.mag.f Maximum phase C current LD0.FLTMSTA1.MaxAmpsN.mag.f Maximum residual current LD0.FLTMSTA1.AmpsA.mag.f Phase A current LD0.FLTMSTA1.AmpsB.mag.f Phase B current LD0.FLTMSTA1.AmpsC.mag.f...
  • Page 26 Section 2 1MAC254287-MB A DNP3 data mappings 61850 Path Default Default Disabled Description Multiplier event Index Class LD0.MPTTR1.StrInhTms.stVal Estimated time to reset of block restart CTRL.CBCSWI1.Pos.stVal CBXCBR1 Switch general DR.RDRE1.FltNum.stVal Number of recordings DR.RDRE1.MemUsed.stVal Rec. memory used REM615 ANSI Point List Manual...
  • Page 27: Section 3 Dnp3 Protocol Implementation

    The table, in combination with the Implementation table and the point list tables provides a complete configuration/interoperability guide for communicating with a device. Table 5: Device profile document DNP3 device profile document Vendor name: ABB Inc. Device name: REM615 Highest DNP level supported: Device function: For requests: Level 2+ ○...
  • Page 28 Section 3 1MAC254287-MB A DNP3 protocol implementation DNP3 device profile document ○ Always ○ When reporting event data (slave devices only) ○ When sending multi-fragment responses (slave devices only) ○ Sometimes ● Configurable as: "Only when reporting event data", or "When reporting event data or multi-fragment messages" Timeouts while waiting for: Data link ○...
  • Page 29: Dnp3 Implementation Table

    Section 3 1MAC254287-MB A DNP3 protocol implementation DNP3 device profile document ○ Only when time-tagged ○ Binary input change with time ○ Only non-time-tagged ○ Binary input change with relative time ● Configurable to send one or the other ● Configurable Sends unsolicited responses: Sends static data in unsolicited responses:...
  • Page 30 Section 3 1MAC254287-MB A DNP3 protocol implementation responded with qualifiers 00 or 01. Requests sent with qualifiers 17 or 28 will be responded with qualifiers 17 or 28. For change-event objects, qualifiers 17 or 28 are always responded. Table 6: Implementation table OBJECT REQUEST (Library will parse)
  • Page 31 Section 3 1MAC254287-MB A DNP3 protocol implementation OBJECT REQUEST (Library will parse) RESPONSE (Library will respond with) Control 3 (select) 17, 28 (index) 129 (response) echo of request relay output 4 (operate) block 5 (direct op) 6 (dir. op, noack) Analog 1 (read) 00, 01 (start-stop)
  • Page 32 Section 3 1MAC254287-MB A DNP3 protocol implementation OBJECT REQUEST (Library will parse) RESPONSE (Library will respond with) Time and 1 (read) 00, 01 (start-stop) 129 (response) 00, 01 (start-stop) 1 (default) date 06 (no range, or all) 17, 28 (index) 07 (limited qty = 1l) 08 (limited qty) 2 (write)
  • Page 33: Section 4 Glossary

    Section 4 1MAC254287-MB A Glossary Section 4 Glossary Analog input module ANSI American National Standards Institute Binary input and output Circuit breaker CBFP Circuit-breaker failure protection CROB Control relay output block Common time of occurrence. The time and date CTO object is an information object that represents the absolute time of day.
  • Page 36 Contact us ABB Inc. Distribution Automation 4300 Coral Ridge Drive Coral Springs, FL 33065, USA Phone +1 (800) 523-2620 Phone +1 954-752-6700 +1 954 345-5329 www.abb.com/substationautomation...