ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS
INSTALLATION AND SERVICE MUST BE PERFORMED BY A
U.S.A.
IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE.
READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
WARNING
flammable vapors and liquids in the vicinity of this or any other appliance.
Cooktop Dimensions
30" Min. *
(76.2 cm)
E
Cooktop Cutout Dimensions
G
MODEL
30'' Ceramic Model
30 ¾ (78.1)
36'' Ceramic Model
36 ½ (92.7)
MODEL
30'' Ceramic Model
29 ¾ (75.6)
36'' Ceramic Model
35 ½ (90.2)
All dimensions are in inches (cm).
**Allow 2" (5 cm) space below cooktop to clear the electric cable and allow for
installation of the junction box on the wall at the back of the cooktop.
Printed in United States
QUALIFIED INSTALLER.
FOR YOUR SAFETY: Do not store or use gasoline or other
A
D
H
Figure 1 ‑ 30" Model shown only
PRODUCT DIMENSIONS
A. WIDTH
B. DePth
21 ½ (54.6)
21 ½ (54.6)
CUT OUT DIMENSIONS
F. WIDTH
MINIMUM
MAXIMUM
30
1
/
(76.5)
8
35
7
/
(91.1)
8
IMPORTANT INSTALLATION‑INFORMATION
• All electric cooktops run off a single phase, three-wire
or four-wire cable, 240/208 volt, 60 hertz, AC only
electrical supply with ground.
• Please note minimum distances between cooktop and
adjacent and overhead cabinetry is 30" (76.2 cm).
* 30" (76.2 cm) min. for unprotected cabinet
24" (61 cm) min. for protected surface
B
C
4" X 8" (10.2 cm x 20.3 cm)
opening at the right rear
to route armored cable
if a panel is present
F
* 30" (76.2 cm) min. for unprotected cabinet
24" (61 cm) min. for protected surface
C. HEIGHT
5 (12.7)
5 (12.7)
G. DePth
MINIMUM
20
3
/
(51.7)
8
20
3
/
(51.7)
8
1
D. BOX WIDth
E. BOX DePth
29 (73.7)
19 ½ (49.5)
34
/
(87.9)
19½ (49.5)
5
8
H. heIght BeLOW
MAXIMUM
COOKtOP
20 ¾ (52.7)
6 (15.2)
20 ¾ (52.7)
6 (15.2)
P/N 318205408 (0911) Rev. B
Canada

Advertisement

Table of Contents
loading

Summary of Contents for Frigidaire 318205408(0901)

  • Page 1 35 ½ (90.2) All dimensions are in inches (cm). **Allow 2" (5 cm) space below cooktop to clear the electric cable and allow for installation of the junction box on the wall at the back of the cooktop. Printed in United States QUALIFIED INSTALLER.
  • Page 2 CAUTION or fire resulting from reaching over heated surfaces, cabinet storage space located above the cooktop should be avoided. If cabinet storage is provided, risk can be reduced by installing a range hood that projects horizontally a minimum of 5" (12.7 cm) beyond the bottom of the cabinets.
  • Page 3: Important Safety Instructions

    When ordering parts for or making inquires about your cooktop, always be sure to include the model and serial numbers and a lot number or letter from the serial plate on your cooktop.
  • Page 4: Electrical Connection

    ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS Electrical connection It is the responsibility and obligation of the consumer to contact a qualified installer to assure that the electrical installation is adequate and is in conformance with the National electrical Code ANSI/NFPA No. 70-latest edition, or with CSA Standard C22.1, Canadian electrical Code,...
  • Page 5: Cooktop Installation

    When ordering parts for or making inquires about your cooktop, always be sure to include the model and serial numbers and a lot number or letter from the serial plate on your cooktop.
  • Page 6 ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS For typical under counter installation of an electric built-in oven see Figure below. Only certain cooktop models may be installed over certain built-in electric oven models. Approved cooktops and built-in ovens are listed by the MFg ID number and product code (see the insert sheet included in the literature package and cooktop installation instructions for dimensions).
  • Page 7 INSTRUCTIONS D'INSTALLATION POUR PLAQUE DE CUISSON ÉLECTRIQUE UN INSTALLATEUR QUALIFIÉ DOIT EFFECTUER Canada IMPORTANT: CONSERVEZ CES INSTRUCTIONS POUR LES INSPECTEURS LOCAUX. LISEZ CES INSTRUCTIONS ET CONSERVEZ-LES POUR RÉFÉRENCES ULTÉRIEURES. d’essence ou d’autres produits inflammables à proximité de cet appareil Dimensions de la plaque de cuisson 30”...
  • Page 8 INSTRUCTIONS D'INSTALLATION POUR PLAQUE DE CUISSON ÉLECTRIQUE L’armoire supérieure ne doit pas excéder une profondeur maximale de 13" (33 cm). Dégagement minimum de 30" (76.2 cm) entre le haut de la surface de cuisson et la base de l’armoire en bois ou en métal non protégée.
  • Page 9: Directives Importantes De Sécurité

    INSTRUCTIONS D'INSTALLATION POUR PLAQUE DE CUISSON ÉLECTRIQUE Installateur 1. Lisez toutes ces instructions avant de procéder à l’installation de la plaque de cuisson. 2. Enlevez tout le matériel d’emballage avant de procéder au raccordement électrique. 3. Observez tous les codes et règlements applicables. 4.
  • Page 10: Connexions Électriques

    INSTRUCTIONS D'INSTALLATION POUR PLAQUE DE CUISSON ÉLECTRIQUE Connexions électriques Le consommateur est responsable et doit communiquer avec un installateur qualifié pour s'assurer que l'installation électrique est adéquate et conforme avec le National Electrical Code ANSI/NFPA No. 70-dernière édition, ou avec la norme ACNOR C22.1, partie 1, du code canadien de l'électricité, et les codes et règlements locaux.
  • Page 11: Installation De La Plaque De Cuisson

    INSTRUCTIONS D'INSTALLATION POUR PLAQUE DE CUISSON ÉLECTRIQUE Installation de la plaque de cuisson 1.Vérifiez si la plaque de cuisson est endommagée. Veillez également à ce que toutes les vis de la plaque de cuisson soient bien serrées (Figure 6). Figure 6 2.
  • Page 12 INSTRUCTIONS D'INSTALLATION POUR PLAQUE DE CUISSON ÉLECTRIQUE L'installation typique d'un four encastré électrique sous le comptoir est présentée à la figure 9. Seulement certains modèles de tables de cuisson peuvent être installés au-dessus de certains modèles de fours encastrés. Les modèles approuvés pour être combinés sont identifiés à...

Table of Contents