Page 1
S2419H_S2419HN_2419NX 1. Disassembly Procedures: Step Figure Remark Turn off power, S1.The FRONT Unplug external cables VIEW from product To remove the stand: 1. Press and hold the stand release button. 2. Lift the stand up and away from the monitor. S2.Remove the Note: STAND-BASE To prevent scratches on ASS’Y the LCD screen while removing the stand,...
Page 2
S4.Disconnect the pins and remove the tapes Use a Philips-head screwdriver to remove 6 screws for remove S5.Remove the speaker. screws to remove (No.1~6 screw the speaker size=M3x6; Torque=6±1kgf.cm) Only for S2419H model...
Page 3
S2419H_S2419HN_2419NX Use a Philips-head screwdriver to remove 3 S6.Remove the screws for remove screws to remove mainframe (No.1~3 screw the mainframe size=P3x4; Torque= 3±0.5kgf.cm) Use a Philips-head screwdriver to remove 10 screws for remove S7.Remove the screws to remove middle frame the middle frame (No.1~10 screw size=M3x3;...
Page 4
S2419H_S2419HN_2419NX S9.The panel S10.Remove the Key Board...
Page 5
S2419H_S2419HN_2419NX S11.The Middle frame Use a Philips-head screwdriver to remove 5 S12.Remove the screws for remove main srews to remove board and converter the main board board and converter (No.1~5 screw board size=D3x6; Torque=6±1kgf.cm) S13.Remove the electrolyte capacitors S14. The (height <...
Page 6
S2419H_S2419HN_2419NX S15.The Main Frame...
S2419H_S2419HN_2419NX 2. Product material information The following substances, preparations, or components should be disposed of or recovered separately from other WEEE in compliance with Article 4 of EU Council Directive 75/442/EEC. Capacitors / condensers (containing No used PCB/PCT) Mercury containing components No used Batteries No used...