30" DUAL FUEL SLIDE-IN RANGE INSTALLATION INSTRUCTIONS
INSTALLATION AND SERVICE MUST BE PERFORMED BY
IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE.
READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
If the information in this manual is not followed exactly, a fire or explosion may
result causing property damage, personal injury or death.
FOR YOUR SAFETY:
— Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS:
•
Do not try to light any appliance.
•
Do not touch any electrical switch; do not use any phone in your building.
•
Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
•
If you cannot reach your gas supplier, call the fire department.
— Installation and service must be performed by a qualified installer, service agency or the gas supplier.
Do not pinch the power supply cord or the flexible gas
conduit between the range and the wall.
Do not seal the range to the side cabinets.
**NOTE: 30" (76.2 cm) minimum clearance between the
cooktop and the bottom of the cabinet when the bottom
of wood or metal cabinet is protected by not less than ¼"
(0.64 cm) flame retardant millboard covered with not less
than No. 28 MSG sheet metal, 0.015" (0.4 mm) stainless
steel, 0.024" (0.6 mm) aluminum, or 0.020" (0.5 mm)
copper.
36" (91.4 cm) minimum clearance when the cabinet is
unprotected.
• NOTE: Allow at least 19 ¼" (48.9 cm) clearance for door
depth when it is open.
• Door Open
B
(see note)
A. HEIGHT
B. WIDHT
35 3/8" (90 cm) -
30"
36 3/8" (92 cm)
(76.2 cm)
G. Minimum Cutout Depth is increased to 24" (61 cm) with backguard.
NOTE: Wiring diagram for these appliances are enclosed in this booklet.
(Models with an Electric Oven and a Gas Cooktop)
A QUALIFIED INSTALLER.
Shave Raised
Edge to Clear 30"
(76.2 cm) Wide
Cooktop Rim.
(3.8 cm Max.)
Locate Cabinet
Doors 1" (2.5
cm) Min.
C
from Cutout
23 ½"
Opening.
(59.7 cm)
*Note: 29"
(73.7 cm) Wide
Opening for
Overlapping
Cooktop and
A
Built-in Look.
If Installing Model With
Optional Side Panels,
Cutout Area Including
Countertop Must Be At
Least 30" (76.2 cm) Wide.
Regulator
C. DEPTH
F. MINIMUM
G. CUTOUT
TO FRONT
CUTOUT
DEPTH
OF RANGE
WIDTH
26 1/4"
29"
21 3/4"
(66.7 cm)
(73.7 cm)
(55.2 cm)
3" Min.
(7.6 cm Min.)
1 ½" Max.
From Wall (if
there is one)
This Side
Only
30"
(76.2 cm)
Exact
H
G
Grounded Jonction Box or Wall
Outlet Should Be Located 8"
From Right Cabinet and 2" to
4" (5.1 cm to 10.2 cm) From
H. HEIGHT OF
COUNTERTOP
36" (91.4 cm) standard
35 3/8" (90 cm) min.
1
30" Min.
(76.2 cm Min.)
30" Min.**
(76.2 cm Min.**)
18" Min.
(45.7 cm) Min.
F
Approx. 1 7/8"
(4.8 cm)
to 17" (20.3 cm to 43.2 cm)
Floor.
22 7/8"
(58.1 cm)
1 1/8"
(45.7 cm)
FRONT
G
OF
Ref.
CABINET
P/N 318201657 (0206) Rev. C
English – pages 1-11
Español – páginas 12-22
Wiring Diagrams - pages 23-25
13"
(33 cm)
24" Min.
(61 cm Min.)
Notes - 26-28