Page 1
C Prox Ltd (inc Quantek) Unit 11 Callywhite Business Park, Callywhite Lane, Dronfield, S18 2XP +44(0)1246 417113 sales@cproxltd.com www.quantek.co.uk WAVE500-2B & WAVE500-2 Manual 1. Antenna connection 2. BUS-L (+, -, L) 3. Channel 1 operation LED 4. Channel 2 operation LED 5.
Page 2
TECHNICAL CHARACTERISTICS WAVE500-2 WAVE500-2B Frequency 868.35MHz Coding High security rolling code Memory 500 codes Number of relays 2 (expandable to 4) Supply 230Vac 12/24Vac/dc Power supply range ±10% 9-23 / 22-35Vdc 8-16 / 16-27Vac Relay contacts Standby/Op. consumption 35mA / 50mA 60mA / 350mA Access control output BUS-L...
Page 3
Configuration of transmitter programming in the receiver R1 LED R2 LED Standard programming (default option, the receiver is always configured on pluri-channel) The relays are activated 1 relay by channel 1, 2 relay by Flashing Flashing channel 2 (3 relay by channel 1, 4 relay by channel 2) Special programming By pressing any transmitter channel, relay 1 on the receiver will...
Page 4
This unit must only be handled by a specialised installer, by his maintenance staff or by a duly trained · operator. The instruction manual for this unit must always remain in the possession of the user. · Terminals of maximum section 3,8mm 2 must be used for the power supply connections. ·...