hit counter script
Honeywell DUAL TEC DT8320AF4 Installation

Honeywell DUAL TEC DT8320AF4 Installation

Ceiling mount motion sensor

Advertisement

DT8320AF4 / DT8320AF5 DUAL TEC® Ceiling Mount Motion Sensor
1
E
3
A
E
[A] = Trous de montage mural / Orificios de montaje fijos / Fixed mounting holes
[B] = Fentes de montage réglables de 61 mm à 85 mm (2,4 In - 3,3 In) / Ranuras de montaje ajustables de 61 mm y
85 mm (2,4" y 3,3") / Adjustable mounting slots from 61mm-85mm (2.4"-3.3")
[C] = Trou d'autoprotection / Orificio para interruptor de seguridad / Tamper hole
To ensure that the sensor remains within the scope of the approvals, a proper mounting of the rear housing to a
solid surface is mandatory. It must also be ensured that the "off the wall" tamper protection contact retains its
functionality.
*Cet accessoire n'est pas couvert par l'agrément. / *Este accesorio está sujeto a aprobación. / *This accessory is not
covered by the approval.
Exemples de câblage / Ejemplos de cableado / Wiring Examples
Alarme, sabotage et problème/Anti-masque
configuré pour une boucle.
Alarma, sabotaje y problema/Anti-máscara
configurado a un bucle.
Alarm, Tamper and Trouble/Anti-Mask
configured to one loop.
Alarme, sabotage et problème/Anti-Mask
configurado para dois loops.
Alarma, sabotaje y problema/Anti-máscara
configurada a dos bucles.
Alarm, Tamper and Trouble/Anti-Mask
configured to two loops.
5
A
E
2
A
E
[EN] = installation agréé / instalación homologado / approved installation
4
A
E
RA = Alarme EOL résistance
RT = Tamper EOL résistance
RA = Alarme EOL résistance
RT = Resistencia EOL a la
manipulación
RA = Alarm EOL resistor
RT = Tamper EOL resistor
- 1 -
RF = Résistance EOL anti-masque
R1 = 1 et 2 résistance de
connexion en boucle.
RF = Résistance EOL anti-masque
R1 = Resistencia de conexión de 1
y 2 bucles.
RF = Anti-Mask EOL resistor
R1 = 1 and 2 loop connection
resistor.

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell DUAL TEC DT8320AF4

  • Page 1 DT8320AF4 / DT8320AF5 DUAL TEC® Ceiling Mount Motion Sensor ○ ○ [EN] = installation agréé / instalación homologado / approved installation ○ ○ [A] = Trous de montage mural / Orificios de montaje fijos / Fixed mounting holes [B] = Fentes de montage réglables de 61 mm à 85 mm (2,4 In - 3,3 In) / Ranuras de montaje ajustables de 61 mm y 85 mm (2,4”...
  • Page 2 Remarques Honeywell Security and Fire, declares that this type radio equipment (whose exact reference can be found on the first page of the manual) complies with directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet •...

This manual is also suitable for:

Dual tec dt8320af5

Table of Contents