Optional Equipment and Accessory Standard probing technics can be performed, ABB encourages user to use co-axial cable for output signal measurement in order to examine the ideal performance of DJT090. User is recommended to prepare following equipment and accessory for proper measurement and on-board pulse load control.
Page 5
Redundant SMA socket for pulse load current read back (DNP) M_VOUT SMA socket for output voltage measurement PMBus PMBus port for connecting to ABB USB to I2C dongle, notice Pin1 location IN/OUT_SYNC SMA socket for measure SYNC signal SWITCH Mechanical switch for turn on/off EVM, notice on/off direction...
720A. Cable voltage drop must be controlled in this application. For continuous 360A and above operation, ABB recommends user to develop proper bus bar to distribute currents. Multiple DC load in parallel is a must for sinking 720A. In general, output connection should be kept as short as possible by means of reducing voltage drop on each cable.
All ABB measurement are evaluated at 12V rated input. The default output of DJT090 EVM is set to be 1.2V. Connect ABB USB to I2C dongle to PMBus port (notice pin 1 location) with PC, then use ABB DPI-CLI tool to start the DJT090 (PMBus turn on is required for the first time, it can be changed to EN turn on via PMBus once the EVM is confirmed to be functional correctly).
CHANNEL REDUCTION ABB supplies 4 and 8 parallel EVM by default. If 2,3,5,6,7 DJT090 operation is desired, PMBus reconfiguration is a must and board modification is recommended. Each channel contains an output shunt resistor. By removing the shunt resistor, the associated DJT090 and its output capacitors will be disconnected to the loading point.
For example, configure used channels as PMBus startup and configure unused channels as EN startup. This potentially will prevent unused channels to operate. Consult local ABB FAEs for more details. PMBUS COMMANDS In this application note, only limited commands are included. All settings must be saved to user NVM before power cycle, otherwise all changes will be lost.
8-channel EVM from manufacturing setting. See appendix for CLI-DPI script examples. To be noted, master device USER_CONFIG(0x01) must be configured before slave devices. Consult local ABB FAEs for more info. Register to be modified: •...
Page 16
Any reproduction, disclosure to third parties or utilization of its contents – in whole or in parts – is forbidden agreed particulars shall prevail. GE by ABB does not accept any responsibility whatsoever for potential errors or possible lack of without prior written consent of GE by ABB information in this document.