hit counter script
NEC SL 1000 Technical Training Manual

NEC SL 1000 Technical Training Manual

System installation
Hide thumbs Also See for SL 1000:

Advertisement

Next Topaz
- Technical Training -
(System Installation)

Advertisement

Table of Contents
loading

Summary of Contents for NEC SL 1000

  • Page 1 Next Topaz - Technical Training - (System Installation)
  • Page 2: Part 1 : Hardware Installation

    Part 1 : Hardware Installation...
  • Page 3: Important Notice

     In places where water or other fluids comes in contact with the equipment.  In areas near high-frequency machines or electric welders.  Near computers, telexes, microwaves, air conditioners, etc.  Near radio antennas (including short-wave) Page 3 © NEC Corporation 2009 NEC Confidential...
  • Page 4: Wall Mounting

    บริ ษ ั ท โปรเฟสชั � น แนล พี เ อบี เ อ็ ก ซ์ จํ า กั ด โทร. 02-519-1718 Hotline. 084-920-5065 Wall Mounting (1) KSU Wall Mounting (arrange lengthways) The Main KSU (1632M-A)and Expansion KSU s (1632ME-A)must be mounted onto the wall. Before installing, secure appropriate spacing as below. Page 4 © NEC Corporation 2009 NEC Confidential...
  • Page 5 บริ ษ ั ท โปรเฟสชั � น แนล พี เ อบี เ อ็ ก ซ์ จํ า กั ด โทร. 02-519-1718 Hotline. 084-920-5065 Wall Mounting (2) KSU Wall Mounting (arrange sideways) Page 5 © NEC Corporation 2009 NEC Confidential...
  • Page 6 (1632ME KSU) not enough!! No.2 Exp KSU No.1 Exp KSU (1632ME KSU) (1632ME KSU) No.1 Exp KSU Main KSU (1632ME KSU) (1632M KSU) Main KSU No.3 Exp KSU (1632M KSU) (1632ME KSU) Page 6 © NEC Corporation 2009 NEC Confidential...
  • Page 7: Ksu Grounding

    • Connect “ ETH” lug to the verified Earth Ground point by using 14AWG (2.0mm) wire.  Grounding must be done each KSU respectively.  Grounding is required not only for system protection but also for Caller-ID detection. Page 7 © NEC Corporation 2009 NEC Confidential...
  • Page 8: Power Failure Transfer

    • Change the switch position of “J6” from “KT” to “PF”. (Default : KT) All terminals on Slot No.4 must be Analog Terminals. Trunk Port Ext. Port No. 1 No. 8 No. 4 No. 16 No. 7 No. 24 Connected extension must be SLT. Page 8 © NEC Corporation 2009 NEC Confidential...
  • Page 9  DO NOT run the cable near the high frequency generating device.  Use cable protectors in case the cables are run on the floor.  Aerial distribution wiring is NOT allowed.  Trunks must be installed with Lightning Arresters. Page 9 © NEC Corporation 2009 NEC Confidential...
  • Page 10 บริ ษ ั ท โปรเฟสชั � น แนล พี เ อบี เ อ็ ก ซ์ จํ า กั ด โทร. 02-519-1718 Hotline. 084-920-5065 Cabling (2) Modular Cable Modular Cable (4-wire, Straight) (2-wire, Straight) Key Telephone DSS Console  Key TEL / DSS Console wiring have “Polarity”.  SLT wiring does not have “Polarity”. Page 10 © NEC Corporation 2009 NEC Confidential...
  • Page 11: Cable Length

    Max 100 m (VoIP / Ethernet Cable) PZ-IPLA IP Terminal / Max 500 m (0.5mm) <P-P> ISDN BRIU Terminal Max 100 / 300 m (0.5mm) <P-MP : Short / Long> Max 50 m (0.5mm) <P-P> ISDN PRIU Terminal Page 11 © NEC Corporation 2009 NEC Confidential...
  • Page 12 บริ ษ ั ท โปรเฟสชั � น แนล พี เ อบี เ อ็ ก ซ์ จํ า กั ด โทร. 02-519-1718 Hotline. 084-920-5065 408E / 008E Installation • 408E / 008E cards are installed in the 1632M / 1632ME KSU. Page 12 © NEC Corporation 2009 NEC Confidential...
  • Page 13: Optional Items Installation

    บริ ษ ั ท โปรเฟสชั � น แนล พี เ อบี เ อ็ ก ซ์ จํ า กั ด โทร. 02-519-1718 Hotline. 084-920-5065 Optional Items Installation (1) EXIFB-C1 • Either EXIFB-C1 card can be installed at 1632M KSU. Page 13 © NEC Corporation 2009 NEC Confidential...
  • Page 14 Part 2 : System Start Up & Programming...
  • Page 15: Customer Data

    • Automatically be saved to the memory on 1632M KSU. Backed up by Lithium Battery. • Can be saved to the CF Card which is inserted to “CF Slot” at VM-21 • Can be saved to your PC by PC PRO software. Page 15 © NEC Corporation 2009 NEC Confidential...
  • Page 16: System Start-Up

    4. Release “Load” Button. 5. Wait about 1-2 min. HOT Start Main software and “Customer” data will be loaded. (System Reset) 1. AC Power Switch ON. AC Power Switch OFF and ON. Page 16 © NEC Corporation 2009 NEC Confidential...
  • Page 17: Accessing Programming

    PC Programming The special application which is provided by NEC-i should be installed on the PC that will be used for PC PRO. Doesn’t need real DRACO system, off-line programming is also available, and the customer data can be saved on the PC.
  • Page 18 1 user • “Auto Log-Out” is available in case nobody operates during pre-programmed period on the Programming from Desktop Terminal and Web PRO. This period is programmable by PRG20-01-12 (Default : 900 sec) Page 18 © NEC Corporation 2009 NEC Confidential...
  • Page 19 Possible to set the data by following the manual. PC Programming The special application which is provided by NEC-i should be installed on the PC that will be used for PC PRO. Doesn’t need real Topaz system, off-line programming is also available, and the customer data can be saved.
  • Page 20 0-9, * and # Enter data into a Program HOLD Complete the programming (ENTER Key) Switch the cursor between 1st and 2nd Display Mute Exit one step at a time (ESC Key) Page 20 © NEC Corporation 2009 NEC Confidential...
  • Page 21: Program Number

    01 : Time and Date 01 : Year 11 : System Numbering 02 : Location Setup 02 : Month Some of Programs does not have “Item No.”. In this case, enter “01” at Item column. Page 21 © NEC Corporation 2009 NEC Confidential...
  • Page 22: Concept Of Slot Number

    บริ ษ ั ท โปรเฟสชั � น แนล พี เ อบี เ อ็ ก ซ์ จํ า กั ด โทร. 02-519-1718 Hotline. 084-920-5065 Concept of Slot Number The system may ask you the “Slot No.” in the specified Program Number. Page 22 © NEC Corporation 2009 NEC Confidential...
  • Page 23: Software Upgrading

    บริ ษ ั ท โปรเฟสชั � น แนล พี เ อบี เ อ็ ก ซ์ จํ า กั ด โทร. 02-519-1718 Hotline. 084-920-5065 Software Upgrading New Main Software will be provided by NEC Infrontia. Procedure 1. Power off the system and disconnect the AC cord from the KSU.
  • Page 24: Software Upgrade

    บริ ษ ั ท โปรเฟสชั � น แนล พี เ อบี เ อ็ ก ซ์ จํ า กั ด โทร. 02-519-1718 Hotline. 084-920-5065 Software Upgrade (1) Page 24 © NEC Corporation 2009 NEC Confidential...
  • Page 25 9. HOT / COLD Start. To check the Main Software Version : (On-Hook Condition) 1.Press “Cursor control key” and Dial “820”. 2.Press “Cursor control key” Main VER: 01.00 MAC: 00-60-B9-C1-B6-04 HKEY: 1900-0000-0000 Page 25 © NEC Corporation 2009 NEC Confidential...
  • Page 26 บริ ษ ั ท โปรเฟสชั � น แนล พี เ อบี เ อ็ ก ซ์ จํ า กั ด โทร. 02-519-1718 Hotline. 084-920-5065 How To check the Main Software Version : Page 26 © NEC Corporation 2009 NEC Confidential...
  • Page 27 The system shall be “OFF” by pressing AC Power switch located at Power Supply. • DO NOT power off by disconnecting the AC power. • In case of 4 Cabinets, Power ON/OFF should be done from 2nd & 3 & 4 Cabinet. Page 27 © NEC Corporation 2009 NEC Confidential...
  • Page 28 Access and enter to the Programming Mode from PC at local or remote site. ISDN DDI ISDN ISDN Remote BRI / PRI Analog Trunk Analog PSTN Modem (Analog) IP Network PZ-VM21 IP VPN (Buili-In Modem) Local Ethernet Cross Cable Ethernet Straight Cable Page 28 © NEC Corporation 2009 NEC Confidential...
  • Page 29 Ethernet Cross Cable. 2. TCP/IP is set to “192.168.0.1” on PC. 3. Open Browser and type “http://192.168.0.10”. (This IP Address is default setting for CD-CP00 Blade. “HOT Start” is necessary if it is changed.) Page 29 © NEC Corporation 2009 NEC Confidential...
  • Page 30: Login Screen

    • Log Out operation must be done. • In case there is no operation about User Name : tech 15 min after Log In, SV8100 shall Password : (IN Password) forcibly do the “Log Out”. Page 30 © NEC Corporation 2009 NEC Confidential...
  • Page 31 It is user friendly GUI design, and the user can easily key-in the data and select the desired data by using pull-down menu at each column without experiences on system programming. Set ! UA Mode Set ! UB Mode System Administrator Extension User Page 31 © NEC Corporation 2009 NEC Confidential...
  • Page 32 - Incoming Ring Group Extension - Speed Dialing Number and Name - Night Mode Switching (Another Group) - DSS Key Assignment - Doorphone Ringing Assignment - Dial-In Name - Telephone Setting - Trunk Setting Page 32 © NEC Corporation 2009 NEC Confidential...
  • Page 33 - Internal Incoming Ring Tone - LCD Language Selection - Toll Restriction Override Password (not Walking Toll Restriction) - User Programming Password - Programmable Function Keys Assignment - Virtual Extension Ring Assignment - One-Touch Key Assignment Page 33 © NEC Corporation 2009 NEC Confidential...
  • Page 34 PC PRO (1) PC PRO software must be installed to your PC. Login Following “Login” dialog appears. Menu Screen Enter the User Name and Password. User Name : tech Password : (IN Password) Page 34 © NEC Corporation 2009 NEC Confidential...
  • Page 35 บริ ษ ั ท โปรเฟสชั � น แนล พี เ อบี เ อ็ ก ซ์ จํ า กั ด โทร. 02-519-1718 Hotline. 084-920-5065 PC PRO (2) Connect PC PRO to the System Click IP Address of Port on CD-CP00 (IP4xx-CPU-A1) (Default IP Address: 192.168.0.10) User Name : tech Click Password : (IN Password) Page 35 © NEC Corporation 2009 NEC Confidential...
  • Page 36 บริ ษ ั ท โปรเฟสชั � น แนล พี เ อบี เ อ็ ก ซ์ จํ า กั ด โทร. 02-519-1718 Hotline. 084-920-5065 PC PRO (3) Menu Tab Menu Screen Menu Tab Standard Wizard System Data (Major settings) (Feature Base) (PRG No. Base) Page 36 © NEC Corporation 2009 NEC Confidential...
  • Page 37 บริ ษ ั ท โปรเฟสชั � น แนล พี เ อบี เ อ็ ก ซ์ จํ า กั ด โทร. 02-519-1718 Hotline. 084-920-5065 PC PRO (4) Blade Configuration Right Click to show the Blade Menu Related PRG No. and/or Feature does not appear without Blade Configuration information. Page 37 © NEC Corporation 2009 NEC Confidential...
  • Page 38 Local / Remote Access Compact flash Empty USB Memory must be connected to the USB port on CD-CP00 during this operation. : more than 128 MB without any security feature FAT (16)) Compact flash Page 38 © NEC Corporation 2009 NEC Confidential...

Table of Contents