Page 1
Installation work must be performed in accordance with the national wiring standards by authorized personnel only. Please retain this installation manual for future reference after reading it thoroughly. WALL MOUNTED Original instruction ARNU07GSBL2 ARNU09GSBL2 ARNU12GSBL2 ARNU15GSBL2 ARNU18GSCL2 ARNU24GSCL2 www.lg.com I.15.LG29.00502.0116 P/NO : MFL69446306...
Page 2
TIPS FOR SAVING ENERGY TIPS FOR SAVING ENERGY Here are some tips that will help you minimize the power consumption when you use the air conditioner. You can use your air conditioner more efficiently by referring to the instructions below: •...
Page 3
IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE. Always comply with the following precautions to avoid dangerous situations and ensure peak performance of your product WARNING It can result in serious injury or death when the directions are ignored CAUTION It can result in minor injury or product damage when the directions are ignored WARNING...
Page 4
IMPORTANT SAFETY INSTRUCTIONS • Do not install the product on a defective installation stand. - It may cause injury, accident, or damage to the product. • Be sure the installation area does not deteriorate with age. - If the base collapses, the air conditioner could fall with it, causing property damage, product failure, and personal injury.
TABLE OF CONTENTS TABLE OF CONTENTS IMPORTANT SAFETY INSTALLATION INSTRUCTIONS Select the best Location Fixing Installation Plate Drill a Hole in the Wall INSTALLATION PARTS Flaring Work - Cut the pipes and the cable INSTALLATION TOOLS - Burrs removal - Putting nut on - Flaring work INSTALLATION MAP - Check...
INSTALLATION PARTS INSTALLATION PARTS Name Quantity Shape Installation plate 1 EA The feature can be changed according to type of model. Type "A" screw 5 EA Type "C" screw 2 EA Screws for fixing panels are attached to decoration panel. INSTALLATION TOOLS Figure Name...
INSTALLATION MAP INSTALLATION MAP Installation plate Sleeve Bushing-Sleeve Putty(Gum Type Sealant) Bend the pipe as closely on the wall as possible, but be careful that it doesn't break. Vinyl tape (Wide) • Apply after carrying out a drainage test. • To carry out the drainage test, remove the air filters Saddle and pour water into the heat...
INSTALLATION INSTALLATION Select the best Location Installation Plate - There should not be any heat or steam near the unit. - Select a place where there are no obstacles around of the unit. - Make sure that condensation drainage can Type "A"...
INSTALLATION Drill a Hole in the Wall Burrs removal 1. Completely remove all burrs from the cut - Drill the piping hole with a ø65 mm hole core cross section of pipe/tube. drill. Drill the piping hole at either the right or the left with the hole slightly slanted to the 2.
INSTALLATION Pull back the tubing holder. Handle Remove pipe port cover and positioning the tubing Yoke Tubing holder Indoor unit back side view Cone Copper pipe Clamp handle Red arrow mark Right Left Backwards Downwards Check Compare the flared work with the figure * The feature can be changed according to type of model.
INSTALLATION Bad case Installation of Indoor Unit - Following bending case from right to left di- Hook the indoor unit onto the upper por- rectly may cause damage to the tubing. tion of the installation plate.( engage the three hooks at the top of the indoor unit with the upper edge of the installation plate) Ensure that the hooks are properly seated on the installation plate by moving...
INSTALLATION <Right side piping> CAUTION If the drain hose is routed inside the room insulate the hose with an insulation mate- rial* so that dripping from sweating conden- sation) will not damage furniture or floors. * Foamed polyethylene or equivalent is recommended.
INSTALLATION Wrap the insulation material Finishing the indoor unit around the connecting portion. installation Overlap the connection pipe insulation ma- Mount the tubing holder in the original terial and the indoor unit pipe insulation positon. material. Bind them together with vinyl Ensure that the hooks are properly seated tape so that there may be no gap.
INSTALLATION Checking the Drainage Do not make drain piping like the follow- ing. To check the drainage. Pour a glass of water on the evaporator. Do not raise Ensure the water flows through the drain hose of the indoor unit without any leak- age and goes out the drain exit.
INSTALLATION Installation of filters Pull out the [Allergy free filter + Triple Fil- ter] from the separately packed plastic bag. Detach the two nitto tapes from the filter. Insert the filter into the filter case. Detach two nitto tapes from the plasma fil- ter.
INSTALLATION Wiring Connection - Connect the wires to the terminals on the control board individually according to the outdoor unit connection. - Ensure that the color of the wires of outdoor unit and the terminal No. are the same as those of indoor unit respectively.
INSTALLATION Group Control Setting Group Control 1 n Wired remote controller 1 + Standard Indoor Units LGAP Network System Signal Master Slave Slave Slave 12 V Display Error Message Only connect serial signal and GND lines between indoor units. Master n DIP Switch in PCB ①...
INSTALLATION * It is possible to connect indoor units since Feb. 2009. * It can be the cause of malfuctions when there is no setting of master and slave. * In case of Group Control, it is possible to use following functions. - Selection of operation, stop or mode - Temperature setting and room temperature check - Current time change...
INSTALLATION Group Control 3 n Mixture connection with indoor units and Fresh Air Intake Unit LGAP Network System Signal Master Slave Master Slave 12 V Display Error Message Display Error Message Master Master * In case of connecting with standard indoor unit and Fresh Air Intake Unit, separate Fresh Air In- take Unit with standard units.
INSTALLATION 2 Remote Control n Wired remote controller 2 + Indoor unit 1 LGAP Network System Slave Slave Slave Signal Master 12 V Display Error Message Master Slave 1. It is possible to connect two wired remote controllers (Max.) with one indoor unit. Set only one indoor unit to Master, set the others to Slave.
INSTALLATION Accessories for group control setting It is possible to set group control by using below accessories. Indoor unit 2 EA +Wired remote controller 1 EA Indoor unit 1 EA +Wired remote controller 2EA * PZCWRCG3 cable used for connection * PZCWRC2 cable used for connection Slave Master...