Outdoor Unit
The heat exchanger coils and panel vents of the outdoor unit should be checked regularly.
If clogged with dirt or soot, the heat exchanger
and panel vents may be professionally steam cleaned.
Dirty or clogged coils will reduce the
NOTICE
operating efficiency of the system and
cause higher operating costs.
(Side)
Air intake
vents
Air outlet
vents
Cleaning Filter
• Recomended use period : About 3 months
1. Open the upside of Front
panel.
Front panel
4. Clean nano plasma filter with
the vacuum cleaner.
(Rear)
Piping
Drain Hose
2. Put up the front panel.
The hook of panel comes off.
Panel
hook
5. Relocate dried nano plasma
filter at the shade and then put
in air filter.
Nano plasma filter
Maintenance and Service
(Side)
Air intake
vents
Air outlet
vents
(Side)
Air intake
vents
Air outlet
vents
3. Remove air filter and then pull
out the nano plasma filter.
Nano plasma filter
(Rear)
Piping
Drain Hose
(Rear)
Piping
Drain Hose